Sintigrafide Gama kamera ile kaynak doku mesafesinin görüntü kalitesine etkisinin kemik lezyonu modellemesi ile incelenmesi
Analyzing the effect of distance between the source of tissue and the colimator on the image quality at the scintigrapic image gained via Gamma camera with the modeling of bone lesion
- Tez No: 335217
- Danışmanlar: PROF. DR. MEHMET NURULLAH KUMRU
- Tez Türü: Yüksek Lisans
- Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
- Anahtar Kelimeler: Nükleer tıp, Nuclear medicine
- Yıl: 2013
- Dil: Türkçe
- Üniversite: Ege Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Nükleer Bilimler Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Gama kameraların Nükleer Tıp Klinik Uygulamalarında kullanımı oldukça yaygındır. Bu kullanım alanlarından biride kanser vakalarında kemik metastazının (kemiğe yayılan tümör dokusunun) kemik sintigrafisi ile tespit edilmesidir. Kemik sintigrafisinde küçük hacimli tümör dokusunun tespit edilebilmesi için elde edilen görüntünün kalitesi önemlidir. Bugüne kadar yapılan çalışmaların çoğunda gama kamera dedektörü ile kaynak arasındaki mesafenin görüntü kalitesi üzerinde bir etkisi olduğu ortaya koyulmuştur. Bu çalışmada 0,8 ml, 0,4 ml, 0,2 ml, 0,1 ml hacimli kemik metestazlarını taklit eden özgün bir model yapılmış, model insan vücudunu taklit eden 10 lt su tankı içine 2cm aralıklarla yerleştirilmiştir. Çalışmada gama kamera kullanarak model üzerindeki farklı hacimlerde ki kemik metastazını, kolimatör kaynak arası mesafenin 40, 35, 30, 25, 20, 15, 10, 5 cm, derinliğin 11, 9, 7, 6, 5, 4, 3, 2, 1 cm olduğu ölçüm değerlerinde sintigrafik ölçümler alınmıştır. Bu çalışmada, farklı boyutlardaki kemik metastazını taklit eden bir modelde, kemik metastazlarının yerinin belirlenmesinde gama kameranın etkinliğinin araştırılması amaçlanmıştır.
Özet (Çeviri)
The usage of Gamma Cameras in the Clinical applications of Nuclear Medicine is quite common. One of the fields in this kind of applications is the diagnosis of the metastasis of bone by means of bone scintigraphy (the tumour tissue which spreads through bone). The provided image in bone scintigraphy is important in order to diagnose the tumour tissue in a small volume. It has been proved in most of the studies which have been held so for that the distance between the Gamma Camera Detector and source has on effect on the display quality. In this study, an authentic model which imitates bone metestasis with the volumes of 0,8 ml, 0,4 ml, 0,2 ml, 0,1 ml and they were placed in a water tank of 10 lt imitating human body. Also, scintigraphy measures with the measuring value in 40, 35, 30, 25, 20, 15, 10, 5 cms of the distance between callimatorand the source and 11, 9, 8, 7, 6, 5, 4, 3, 2, 1 cms of depth have been taken using the Gamma Camera on the bone metastasis in different sizes on the model. Furthermore, the research of the Gamma Cameras activity in the identification of the location of bone metestasis with a model which imitates bone metestatis in different sizes has been aimed.
Benzer Tezler
- Farklı gama kameralarla vertebra fantom kullanılarak kemik sintigrafi çekimlerinin değerlendirilmesi
Evaluation of scintigraphy with different gamma cameras by using vertebra phantom
ERCAN ARSLAN
- İrritabl barsak sendromlu hastalarda safra dinamiklerinin nitrogliserin ile güçlendirilmiş kantitatif hepatobiliyer sintigrafi ile değerlendirilmesi
Başlık çevirisi yok
CANDAN COŞKUN
Tıpta Uzmanlık
Türkçe
1998
Radyoloji ve Nükleer TıpOndokuz Mayıs ÜniversitesiNükleer Tıp Ana Bilim Dalı
- Helikobakter pilori enfeksiyonunun biliyer sisteme olan etkilerinin hepatobiliyer sintigrafi ile araştırılması
Başlık çevirisi yok
BANU KIRTILOĞLU
Tıpta Uzmanlık
Türkçe
2005
Radyoloji ve Nükleer TıpOndokuz Mayıs ÜniversitesiNükleer Tıp Ana Bilim Dalı
PROF.DR. MURATHAN ŞAHİN
- Pulmoner emboli şüphesi olan hastalarda TC-99M MAA ile planar görüntüleme ve üç boyutlu görüntüleme sağlayan SPECT değerlendirmesi
Suspected pulmonary embolism in patients with TC-99M MAA planar imaging and providing three-dimensional SPECT imaging assessment
KIVILCIM KANTAR TERKURAN
Tıpta Uzmanlık
Türkçe
2010
Radyoloji ve Nükleer TıpOndokuz Mayıs ÜniversitesiNükleer Tıp Ana Bilim Dalı
PROF. DR. MURATHAN ŞAHİN