Dijital implant ölçü netliğinin artırılmasına etkili parametrelerin incelenmesi
Evaluation of the parameters effecting the accuracy of digital implant impressions
- Tez No: 858722
- Danışmanlar: PROF. DR. BİLGE GÖKÇEN RÖHLİG
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Protez, İmplantüstü Protez, Dijital ölçü postu, Dijital Ölçü, Prosthesis, İmplant Supported Prosthesis, Scanbody, Digital İmpression
- Yıl: 2024
- Dil: Türkçe
- Üniversite: İstanbul Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Göksoy G., (2024). Dijital İmplant Ölçü Netliğinin Artırılmasına Etkili Parametrelerin İncelenmesi. İstanbul Üniversitesi Sağlık Bilimleri Enstitüsü, Protetik Diş Tedavisi ABD. Doktora Tezi. İstanbul. Dental implantların dijital ölçüleri yaygın olarak kullanılmaktadır ve dişsiz çenelerin tam ark taramaları için tek ve kısmi dişsiz boşluklara göre daha düşük doğruluk sonuçları vermektedir. Mevcut araştırmanın amacı, çoklu implantlı dişsiz arkların dijital ölçülerinin doğruluğu üzerinde, tarama gövdesi malzemesinin ve ek referans alanlarının etkisini değerlendirmektir. Ana model olarak altı implantlı (BLT, RC, Institut Straumann, AG) dişsiz bir maksilla modeli kullanılmıştır. PEEK ve PMMA tarama gövdeleri implantlara yerleştirilmiş ve bir ağız içi tarayıcı (TRIOS4, 3Shape) ile dijital ölçüler alınmıştır. Dişsiz boşluklara akışkan kompozit (C), dişeti bariyer materyali (GB), taranabilir silikondan (S) yapılmış referans işaretleyiciler yerleştirilmiş ve ölçüler alınmıştır. Ana model, yüksek çözünürlüklü bir referans tarayıcı ile dijitalleştirilmiştir. Önceden belirlenen noktaların sapmaları ve implantlar arası mesafeler çakıştırma tekniği kullanılarak hesaplanmıştır. Çoklu karşılaştırmaları belirlemek için Mann Whitney U ve Kruskal Wallis-H testi yapılmıştır. İmplantlar arası mesafe ölçümleri, PEEK tarama gövdelerinin PMMA tarama gövdelerinden daha iyi hassasiyet gösterdiğini göstermiştir (Ortalama sapmalar; PEEK: 40±4 mµ, PMMA: 127±6 mµ, p<.001). Alt gruplarda da PEEK grupları PMMA gruplarına göre daha doğru sonuçlar vermiştir (p<.001). Kruskal-Wallis testi de kesinlikte gruplar arasında önceden belirlenmiş noktaların sapmalarında istatistiksel olarak farklılık göstermiştir (p<.001). Ek referans alanlarının eklenmesi, PEEK gruplarında ölçünün kesinliği ve doğruluğu etkilememiştir. PEEK tarama gövdeleri kullanıldığında, referans işaretçilerin eklenmesi dijital ölçülerin doğruluğunda herhangi bir anlam ifade etmemektedir. PMMA, tarama gövdesi malzemesi olarak alternatif bir malzeme gibi görünmüyor, ek referans alanlarının eklenmesi gerekmektedir. Ancak farklı tarama teknolojileri ile daha ileri çalışmalar yapılmalıdır.
Özet (Çeviri)
Goksoy G. (2024). Evaluation of the Parameters Effecting the Accuracy of Digital Implant Impressions İstanbul University, Institute of Health Science, Department of Prosthodontics Doctorate Thesis Istanbul. The aim of current research is to evaluate the effect of scanbody material and additional reference markers in the form of artificial landmarks on the accuracy of digital impressions of edentulous arches with multiple implants. A model of an edentulous maxilla with six implants (BLT, RC, Institut Straumann, AG) was used as master model. PEEK and PMMA scanbodies were screwed on the implants and digital impressions were obtained with an intraoral scanner (TRIOS4, 3Shape). Reference markers made of flowable composite (C), gingival barrier material (GB), scannable silicone (S) were placed on the edentulous spaces and impressions were obtained. The master model was digitalized with an extraoral high-resolution reference scanner. Deviations of the predetermined points and inter-implant distances were calculated by using superimpositining technique. Inter-implant distance measurements showed that PEEK scanbodies demonstrated better precision than PMMA scanbodies, (p<.001). In the subgroups, also PEEK groups were more accurate than PMMA groups (p<.001). Kruskal-Wallis test also showed statistical difference in deviations of the predetermined points among the groups in precision (p<.001). Addition of markers did not influence the precision and trueness in PEEK groups but in PMMA groups both in distance measurements and predetermined point deviations. Addition of reference markers does not make any significance in the accuracy of digital impressions when PEEK scanbodies are used. PMMA seems not to be an alternative material as scanbody material, addition of markers is needed.
Benzer Tezler
- İmplant sayısı ve farklı dijital ölçü tekniklerinin ölçü netliğine olan etkisinin in vitro değerlendirilmesi
Influence of implant number on the accuracy of photogrammetric and intraoral digital impression systems in full-arch implant rehabilitation: An in vitro study
ALİ CAN YENİ
Doktora
Türkçe
2026
Diş Hekimliğiİstanbul ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. FATMA GÜLBAHAR IŞIK ÖZKOL
- Comparison of the accuracy and time efficiency between conventional and two digital systems impressions of single tooth implant
Tek diş implantlarda konvansiyonel ve iki farklı ölçü sisteminin ölçü netliğinin ve çalışma zamanının karşılaştırılması
MUHAMMED ALİBRAHİM
Yüksek Lisans
İngilizce
2019
Diş HekimliğiMarmara ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DR. ÖĞR. ÜYESİ YILMAZ UMUT ASLAN
- Tam ark implant ölçülerinde dijital ve konvansiyonel yöntemlerin 3 boyutlu netlik karşılaştırılması
Three-dimensional accuracy of conventional vs. digital full-arch implant impressions
BERKMAN ALBAYRAK
Diş Hekimliği Uzmanlık
Türkçe
2019
Diş HekimliğiAtatürk ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. FUNDA BAYINDIR
- Tam ark implant üstü dijital ölçü doğruluğuna yardımcı yöntemlerin etkisinin İn Vitro olarak incelenmesi
In vitro investigation of the effects of auxiliary methods on the accuracy of full-arch implant digital impressions
HAFİZE DİZEK
Diş Hekimliği Uzmanlık
Türkçe
2024
Diş Hekimliğiİzmir Katip Çelebi ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. SÜLEYMAN AGÜLOĞLU
- Dental implantların dijital ölçü netliğine etki eden faktörlerin araştırılması
Factors which effects the dental implants digital impression
MERVE CİNCİOĞLU
Doktora
Türkçe
2018
Diş Hekimliğiİstanbul ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. BİLGE GÖKÇEN RÖHLİG