Hex ve non-hex vidalı dayanaklarla hazırlanan implant üstü restorasyonların sonlu elemanlar analiz yöntemi ile karşılaştırılması
Comparison of implant supported restorations produced with hex and non-hex screw abutments concept with finite element analysis method
- Tez No: 705806
- Danışmanlar: PROF. DR. MUSTAFA ZORTUK
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dental implantasyon, Dental implantlar, Dental protez-implant destekli, Dental restorasyon, Dental stres analizi, Kemik vidaları, Sonlu elemanlar stres analizi, Implant, abutment, hexagonal connection, finite element analysis, Dental implantation, Dental implants, Dental prosthesis-implant supported, Dental restoration, Dental stress analysis, Bone screws, Finite elements stress analysis
- Yıl: 2021
- Dil: Türkçe
- Üniversite: Hatay Mustafa Kemal Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Giriş ve Amaç: Gelişmekte olan diş hekimliği pratiğinde diş eksikliklerinin tedavisinde implant uygulamaları çok önemli yer tutmaktadır. Protetik diş tedavisi uygulamalarında geleneksel olarak diş eksikliği durumlarında kron köprü protezleri veya hareketli bölümlü protezler uygulanmaktadır. Ancak gelişen implant tedavileri sayesinde bu gibi uygulamaların yerine implant tedavisiyle hastanın kaybedilen dişinin yerine implant üzeri restorasyon yapılarak fonksiyonun iadesi sağlanmış olur. İmplant üstü protezler simante veya vidalı olarak iki çeşit uygulanabilir. Bu çalışmada incelediğimiz tip protezler vidalı dayanaklar kullanarak hazırlanan protezlerdir. Bu çalışmanın amacı, rutin implant üstü köprü restorasyonların tedavilerinde kullanılan non-hex yapıya sahip vidalı dayanakların yerine hex yapıya sahip vidalı dayanak kullanıldığında okluzal kuvvetlere karşı herhangi bir biyomekanik avantajın olup olmadığının stres analiz yöntemiyle incelenmesi ve her iki sisteminde kendi içinde dayanıklılıklarının ölçülmesidir. Gereç ve Yöntem: Bu çalışmada; aynı çap ve boya sahip (4.1mm-10 mm) 2 adet implant alt çene arka bölgede ikinci premolar ve ikinci molar bölgeye tamamen paralel biçimde yerleştirilmek üzere seçilmiştir. Toplam iki adet model oluşturulmuş ve modellerden biri için hekzagonal yapıda implant dayanak bağlantı tasarımına sahip dayanaklar seçilirken diğeri içinse klinik pratikte implant üzeri köprü restorasyonlarında sıklıkla kullanılan non-hekzagonal bağlantı tasarımlı dayanaklar sanal ortamda yerleştirilmek üzere seçilmiştir. Bu seçilen dayanaklar üzerine üç üyeli vida destekli bir metal destekli seramik köprü restorasyon sanal ortamda yerleştirilmiş ve kronların belirli noktalarından dik ve oblik yönde kuvvet ayrı ayrı uygulanarak, toplam 4 adet çalışma grubu elde edilmiştir. Uygulanan kuvvetler sonucunda implant boyun bölgesinde, vidada ve dayanakta meydana gelen Von Mises gerilme değerleri ayrıca kortikal ve spongioz kemikte oluşan maksimum ve minimum principal stres değerleri sonlu elemanlar stres analiz yöntemi yardımıyla incelenmiştir. Bulgular: Hex ve non-hex bağlantı tasarımı olan modeller arasında implant bileşenleri üzerinde farklı stres değerleri gözlenirken kemik üzerinde benzer değerler elde edilmiştir. Bağlantıdaki altıgen tasarımın antirotasyonel etkisi bu stres değerlerinin farklı olmasını etkilemiştir. Ayrıca implant üzerine gelen kuvvetlerden oblik kuvvetler dikey kuvvetlere göre stresi daha fazla arttırıcı yönde etki göstermiştir. Sonuç: Her iki sistemde sınır değerler aşılmadığından kullanılabilir sistemlerdir. Ancak oluşan stres değerlerine bakıldığında hex sistemlerde implant ve iç vidaya gelen stres değerleri non-hex sistemlere göre daha düşüktür. Bu sebeple iki implant arası açı 30 derece aşılmadığı durumlarda hex sistemlerin kullanımının uygun olduğu düşünülmektedir. Anahtar Kelimler: İmplant, dayanak, hekzagonal bağlantı, sonlu elemanlar analizi.
Özet (Çeviri)
Introduction and Aim: Implant treatments have an important role in the rehabilitation of dental deficiencies in developing dentistry practice. In cases of tooth deficiency, traditional treatment options are crowns, bridges and partial dentures.However, due to the developing implant treatments, the implant treatment is replaced with the restoration of the patient's lost tooth, and the function is returned by replacing such applications. Implant prostheses can be applied in two types as cemented or screwed. The types of prostheses we examine in this study are prostheses prepared using screw abutments. The aim of this study is to examine whether there is any biomechanical advantage against occlusal forces when screw abutments with hex structure are used instead of screw abutments with non-hex structure used in the treatment of routine over implant bridge restorations, and to measure their durability in both systems. Materials and Methods: In this study; 2 implants with the same diameter and length (4.1 mm-10 mm) were selected to be placed completely parallel to the first premolar and second molar regions in the posterior region of the lower jaw. A total of two models were created, and for one of the models, abutments with a hexagonal implant abutment design were selected, and for the other, abutments with non-hexagonal connection design, which are frequently used in clinical practice in bridge restorations over implants, were selected to be placed in virtual environment. A three-member, screw-supported, metal-supported ceramic bridge restoration was placed on these selected abutments in a virtual environment, and a total of 4 study groups were obtained by applying vertical and oblique force separately from certain points of the crowns. Von Mises stress values occurring in the implant neck region, screw and abutment as a result of the applied forces, as well as the maximum and minimum principal stress values in cortical and cancellous bone were analyzed with the help of finite element stress analysis method. Results: While different stress values were observed on the implant components between the hex and non-hex connection designs, similar values were obtained on the bone. The antirotational effect of the hexagonal design in the connection affected the difference of these stress values. In addition, oblique forces from the forces on the implant increased the stress more than the vertical forces. Conclusion: Border limit values are not exceeded in both systems, they are usable systems. However, considering the resulting stress values, the stress values on the implant and internal screw in hex systems are lower than in non-hex systems. For this reason, it is thought that the use of hex systems is appropriate when the angle between two implants is not exceeded 30 degrees.
Benzer Tezler
- Oklüzal vidalı sabit restorasyonlardaki farklı abutment seçiminin klinik başarıya etkisinin sonlu elemanlar analizi yöntemi ile incelenmesi
Investigation of the effect of different abutment selection on clinical success in occlusal screw fixed restorations by finite element analysis method
ERSİN ARICAN
Doktora
Türkçe
2023
Diş Hekimliğiİstanbul ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. ALİ BALIK
- Headspace gaz kromatografi kütle spektrometresi kullanarak pediyatrik şurup ve süt örneklerinde benzoik asit tayini
Determination of benzoic acid in pediatric syrup and milk samples by headspace gas chromatography mass spectrometer
NESLİHAN MÜDERRİSOĞLU KEFELİ
Yüksek Lisans
Türkçe
2022
Gıda Mühendisliğiİstanbul Teknik ÜniversitesiKimya Ana Bilim Dalı
PROF. DR. MUSTAFA ÖZCAN
DR. ORHAN DESTANOĞLU
- İstanbul-Silivri-Kavaklı havzası ve dolayının hidrojeolojik incelenmesi
Hydrogeological investigation of Kavaklı (İstanbul-Silivri) basin and vicinity
MUHTEREM ÇOPUROĞLU
Yüksek Lisans
Türkçe
1997
Jeoloji Mühendisliğiİstanbul Teknik ÜniversitesiUygulamalı Jeoloji Ana Bilim Dalı
DOÇ. DR. TURGUT ÖZTAŞ
- Hex ve Non-hex titanyum taban dayanaklar üzerine üretilen çok üniteli monolitik zirkon köprülerde kuvvet dağılımının sonlu elemanlar stres analizi ile karşılaştırılması
Comparison of force distribution with finite element stress analysis in multi-unit monolithic zircon bridges fabricated on Hex and Non-hex titanium-base abutment
DİDEM SAKAR
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş HekimliğiHacettepe ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. MEHMET MUHTAROĞULLARI
- Gut hastalarında kornea endotel hücre morfolojisi ve retina ile optik sinir mikrosirkülasyonunun değerlendirilmesi
Evaluation of corneal endothelial cell morphology and retinal and optic nerve microcirculation in patients with gout
MURAT GÜZEL
Tıpta Uzmanlık
Türkçe
2025
Göz HastalıklarıHatay Mustafa Kemal ÜniversitesiGöz Hastalıkları Ana Bilim Dalı
DR. ÖĞR. ÜYESİ ŞULE BARMAN KAKİL