Geri Dön

İntravenöz katater uygulamasında kullanılan tespit malzemesinin çocuğun emosyonel ve fizyolojik göstergelerine etkisi

The effect of the detection material used in intravenous catheter administration on the emotional and physiological indicators of the child

  1. Tez No: 642207
  2. Yazar: EZGİ GAMZE BURUNSUZ
  3. Danışmanlar: DR. ÖĞR. ÜYESİ SELMİN KÖSE
  4. Tez Türü: Yüksek Lisans
  5. Konular: Hemşirelik, Nursing
  6. Anahtar Kelimeler: Duygusal tepkiler, Fizyolojik parametreler, Kateterizasyon, Kateterizasyon-periferik, Çocuklar, Emotional responses, Physiological parameters, Catheterization, Catheterization-peripheral, Children
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: Biruni Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Hemşirelik Ana Bilim Dalı
  12. Bilim Dalı: Hemşirelik Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Hastanede bulunma, yatma, tedavi sürecinin uzaması çocukların emosyonel ve fizyolojik yönden olumsuz duygular içerisine girmesine sebep olur. Hastanede uygulanan invaziv girişimlerin başında yer alan IV katater yerleştirme işlemi çocuklar için zorlu ve stres yaratan bir durumdur. Araştırma İntravenöz Katater Uygulamasında Kullanılan Tespit Malzemesinin Çocuğun Emosyonel ve Fizyolojik Göstergelerine Etkisini belirlemek amacıyla renklendirilmiş desenli tespit malzemesi kullanılarak gerçekleştirildi. Araştırma verileri Çocuk ve Ebeveyni Tanılama Formu, Çocuklarda Emosyonel Göstergeler Ölçeği(ÇEGÖ), Vital Bulgu Değerlendirme Formu kullanılarak toplandı. Araştırma için etik kurul izni ve ailelerden yazılı onam alındı. Verilerin değerlendirilmesinde yüzde, ortalama, standart sapma, Pearson Ki Kare, Independent t testi, Repeated Measures testi ve Bonferroni testi kullanıldı. Anlamlılık seviyesi p<0,05 olarak kabul edildi. Deney grubuna renklendirilmiş desenli, kontrol grubuna ise rutin bankımda kullanılan beyaz renk tespit malzemesi kullanıldı. Renklendirilmiş desenli tespit malzemesi kullanılan deney grubunda tespit öncesi, tespitten sonra 1. ve 5. dakikada ölçülen oksijen saturasyon değer ortalamalarının birbirine çok yakın olduğu, düz tespit malzemesi grubunda ise oksijen saturasyon ortalamasının tespitten sonra 1. ve 5. dakika da en yüksek seviyeye çıktığı belirlendi. Deney grubundaki çocukların ÇEGÖ puan ortalamalarının, kontrol grubundan anlamlı olarak daha düşük olduğu saptandı(p<0,05). Gruplar arasında tespit sonrası 1. dakikada ki kontrol grubunun değer ortalamasının deney grubuna göre kontrol grubunda daha yüksek olduğu ve aralarında istatistiksel olarak fark olduğu belirlendi. Renklendirilmiş desenli tespit malzemesi dikkati başka yöne çektiği için emosyonel göstergeler üzerinde olumlu etkisi olduğu belirlendi. Çocuklarda IV katater yerleştirme sonrası kullanılan renklendirilmiş desenli tespit malzemesinin çocuk servislerinde kullanımının yaygınlaştırılması ve farklı yaş ve hastalık gruplarında fazla sayıda örneklemin olduğu çalışmalarda etkinliğinin araştırılması önerilir.

Özet (Çeviri)

Hospitalization and prolonged treatment cause emotional and physiological negative emotions in children. IV catheter placement, which is one of the most invasive procedures applied in the hospital, is a difficult and stressful situation. The research was carried out to determine the Effect of the Detection Material Used in Intravenous Catheter Administration on the Emotional and Physiological Indicators of the Child. The research data were collected using the Child and Parent Diagnosis Form, the Emotional Indicators Scale in Children, the Vital Finding Evaluation Form. For study, ethics committee permission and written consent from the families were obtained. Percentage, average, standard deviation, Pearson Chi Square, Independent t test, Repeated Measures test and Bonferroni test were used to evaluate the data. Significance level was accepted as p <0,05.White colored fixing material used in my routine bench was used for the experimental group and colored pattern for the control group. In the experimental group with colored patterned fixing material, it was determined that the oxygen saturation average values measured before and after the fixation were very close to each other, while in the plain fixing material group, the oxygen saturation average increased to the highest level in the 1st and 5th minutes after detection. It was determined that the mean scores of children in the experimental group were significantly lower than the control group (p <0.05). It was determined that the mean value of the control group at the 1st minute after the detection was higher between the groups compared to the experimental group, and there was a statistical difference between them. It was determined that thecolored patterned fixing material had a positive effect on emotional indicators as it attracted attention in another direction. It is recommended to expand the use of colored patterned fixation material used in IV after catheter insertion in children and to investigate its effectiveness in studies with a large number of samples in different age and disease groups.

Benzer Tezler

  1. Periferik intravenöz kateter uygulamasında tespit seti etkinliğinin incelenmesi

    The investigation of the efficiency of fixation set in the performing perifheral intravenous catheter

    ÖZNUR KAVAKLI

    Yüksek Lisans

    Türkçe

    Türkçe

    2009

    HemşirelikGata

    Hemşirelik Esasları Ana Bilim Dalı

    YRD. DOÇ. DR. ŞENAY UZUN

  2. Açık prostatektomi ameliyatı geçirecek hastalarda tek doz ve sürekli spinal anestezinin karşılaştırılması

    Başlık çevirisi yok

    DEMET YEDİÇOCUKLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2003

    Anestezi ve ReanimasyonEge Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    PROF. DR. İBRAHİM YEĞÜL

  3. Kombine spinal epidural anestezide kullanılan izobarik Bupivakain'in yayılımını etkileyen faktörler

    Başlık çevirisi yok

    METİN ÖZMIŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1998

    Anestezi ve ReanimasyonFırat Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. S. ATEŞ ÖNAL

  4. Perkütan nefrolitotomi vakalarında postoperatif analjezi amaçlı uygulanan erektör spina alan bloğunun etkinliği

    The efficiency of the erector spina plane block applied for postoperative analgesia in percutaneous nephrolithotomy

    MEHMET UĞUR BİLGİN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    Anestezi ve ReanimasyonSağlık Bilimleri Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. ZEKİ TUNCEL TEKGÜL

  5. Köpeklerde epidural olarak uygulanan bupivakain morfin kombinasyonunun bolus, aralıklı bolus ve sürekli infüzyonunun etkilerinin karşılaştırılması

    Comparison of effects of epidurally administered bupivacaine morphine combination as bolus, i̇ntermittent bolus and continious i̇nfusion i̇n DOGS

    NURİ UYSAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    Veteriner HekimliğiBurdur Mehmet Akif Ersoy Üniversitesi

    Veterinerlik Cerrahisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ YUSUF SİNAN ŞİRİN