Özet

ÖZET Günümüzde İmmunoglobulinlerin tayininde kullanılan turbidimetri ve nefelometri metodları laboratuvarlarımızda uygulandı. Bu metodlardan hangisinin daha hassas olduğu, rutin ve klinik fayda açısından hangisinin daha kullanışlı olduğu, hangisinin seçileceği veya birbiri yerine kullanılıp kullanılamıyacağı araştırıldı. K.T.Ü. Farabi hastanesinin çeşitli servilerinde tedavi edilmekte olan 50 kişide IgA, IgG, IgM seviyeleri turbidimetrik ve nefelometrik metodlarla aynı anda çalışıldı. İki metodun ortalama değerleri her üç parametre içinde anlamlı düzeyde farklıydı. IgA, IgG ve IgM'nin iki metodla elde edilen ölçüm sonuçlan arasında anlamlı korelasyonlar bulundu. Korelasyon katsayıları (r) IgA için 0.921, IgG için 0.866 ve IgM için 0.588 idi. Nefelometrik metodun hassasiyeti(precision), yüksek düzeyler için sırasıyla IgA, IgG, ve IgM için (%CV) 0.23, 1.94"ve 3.05 düşük düzeyler için sırasıyla (%CV) 3.04, 1.50 ve 2.07 olarak bulundu ve turbidimetrik metodun hassasiyeti, yüksek düzey için sırasıyla IgA, IgG ve IgM için (%CV) 1.45, 3.27 ve 9.5 düşük düzeyler için sırasıyla (%CV) 15.79, 2.27 ve 9.98 olarak bulundu. Nefelometrik metodun doğruluğu (accuracy) IgA, IgG ve Ig M için sırasıyla (%CV) 1.04, 0.84 ve 0.40 turbidimetrik metodun doğruluğu için (%CV) değerleri sırasıyla 1.56, 46.7 ve 4.83 olarak bulundu. Nefelometrik metodun performansı karakteristiklerin turbidimetrik metodtan daha iyi bulunduğundan, pratikliği ve çabukluğuda gözönüne alınarak laboratuvarlarda tercih edileceği kanaatine varıldı.

Özet (Çeviri)

SUMMARY Turbidimetric and nefelometric methods nowadays used in the determination of immunoglobulins were employed in our laboratory Between these two methods. Which one is more sensitive, which is more useful from the point of serving as routine and whether one can be used in choice of other were investigated. In 52 patients hospitalized in various clinics of K.T.Ü. Farabi Hospital, IgA, IgG and IgM levels were studied of the some time using. Turbidimetric and nephelometric methods. The mean volues for an three parameters in two methods were (significantly)different. Between the results two methods for IgA, IgG and IgM, significant correlations were found. The correlation coefficients (constants) (r) for IgA, IgG and IgM 0.925, 0.866 and 0.588, respectively. The precision of nephelometric method for high levels (CV%)were 3.04, 1.50 and 2.08 for IgA, IgG and IgM, respectively. The precision of turbidimetric method for high levels (CV%) were 1.45, 3.27 and 9.5 and for low levels (CV%)15.71, 2.27 and 9.95 for IgA, IgG and IgM, respectively. The accuracy of nephelometric method for IgA, IgG and IgM were 1.04, 0.84 and 0.40 and that of turbidimetric method for IgA, IgG and IgM were 1.56, 4.67and 4.83 respectively. For it's better performance characteristig and being practice and fast, nephelometry was shown to be more preferable compaired to turbidimetry.

Benzer Tezler

  1. Turbidimetrik ve nefelometrik kompleman tayin metodlarının karşılaştırılması

    Coparision of turbidimetric and nephelometric methods for determination of complemans

    DERYA VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1996

    BiyokimyaKaradeniz Teknik Üniversitesi

    PROF.DR. EKİN ÖNDER

  2. Çeşitli pişirme yöntemlerine bağlı olarak dana etindeki metiyonin ve lisin miktarı değişimlerinin mikrobiyolojik yöntemlerle belirlenmesi

    Başlık çevirisi yok

    NİHAL TÜRKMEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1993

    Gıda MühendisliğiAnkara Üniversitesi

    Gıda Bilimi ve Teknolojisi Ana Bilim Dalı

    PROF. DR. VELİTTİN GÜRGÜN

  3. Investigation of polyanion polycation interactions in an aqueous solution by conductometry

    Sulu çözeltilerdeki polianyon polikatyon girişimlerinin kondüktometrik yöntemle incelenmesi

    NERMİN ACAR

    Yüksek Lisans

    İngilizce

    İngilizce

    1994

    Kimyaİstanbul Teknik Üniversitesi

    DOÇ.DR. TÜLAY TULUN

  4. Juvenil diabetiklerde eksersiz sırasında idrarla protein atılımı

    Başlık çevirisi yok

    UĞUR YALINBAŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    HematolojiSağlık Bakanlığı

    Dahiliye Ana Bilim Dalı