Kurşun-kadmiyum tozunun hidroklorik asitle çözündürülmesinin optimizasyonu
The Optimization of dissolution of lead-cadmium powder in hydrochloric acid solutions
- Tez No: 121449
- Danışmanlar: PROF. DR. SABRİ ÇOLAK
- Tez Türü: Yüksek Lisans
- Konular: Kimya Mühendisliği, Chemical Engineering
- Anahtar Kelimeler: Kurşun -kadmiyum tozu, liçing, çözünme, optimizasyon, Taguchi metodu, Hidroklorik asit, Kadmiyum, Kurşun, Taguchi yöntemi, Lead-cadmium powder, leaching, dissolution, optimization, Taguchi method, Hydrochloric acid, Cadmium, Lead
- Yıl: 2002
- Dil: Türkçe
- Üniversite: Atatürk Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Kimya Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
ÖZET Y.Lisans Tezi KURŞUN - KADMİYUM TOZUNUN HİDROKLORİK ASİT ÇÖZELTİLERİ İLE ÇÖZÜNDÜRÜLMESİNİN OPTİMİZASYONU Nurcan BORULU Atatürk Üniversitesi Fen Bilimleri Enstitüsü Kimya Mühendisliği Anabilim Dalı Danışman : Prof.Dr. Sabri ÇOLAK Kayseri 'de bulunan Çinkur fabrikasından temin edilen kurşun-kadmiyum tozundaki çinko, kadmiyum ve kurşunun HC1 çözeltisi ile liçinginin optimum çalışma şartları“Taguchi Yöntemi”ile belirlenmiştir. Çözünme hızı üzerine katı-sıvı oranı, reaksiyon sıcaklığı, reaksiyon süresi, karıştırma hızı ve asit konsatrasyonunun etkileri araştırılmıştır. Sonuçta, çözünürlüğün katı-sıvı oranının azalmasıyla, karıştırma hızı, reaksiyon sıcaklığının ve asit konsantrasyonunun artmasıyla arttığı görülmüştür. Ayrıca; Reaksiyon süresinin artmasıyla ise, çözünme hızının önce artığı ve belirli bir süreden sonra azaldığı tepit edilmiştir. Optimum çalışma şartlan: katı/sıvı oranı; 0.1, reaksiyon sıcaklığı; 65°C, reaksiyon süresi; 48 (dak), karıştırma hızı; 700 (rpm), asit konsantrasyonu; 3M, olarak bulunmuştur. Bu opimum proses şartlan altında, çinko için % 97, kadmiyum için % 91 ve kurşun için % 0.052 'lik bir liçing verimi sağlanmıştır. 2002, 97 sayfa
Özet (Çeviri)
ABSTRACT Master Thesis THE OPTIMIZATION OF DISSOLUTION OF LEAD-CADMIUM POWDER IN HYDROCHLORIC ACID SOLUTIONS Nurcan BORULU Atatürk Universty Graduate School of Natural And Applied Sciences Deparmant of Chemistry Engineering Supervisor : Sabri ÇOLAK Taguchi method was applied to determine the optimum conditions for the leaching of zinc, cadmiyum and lead in lead-cadmium powder supplied from Çinkur factory in Kayseri by HC1 solutions. In conclusion, it was observed that the dissolution rate increased with the decrease of solid-liquid ratio and the increase of stirring speed reaction temperature and acid concentration. More over, it was determined that the dissolutionrate first increase of reaction time and decreased after a definite time. In the experiment; solid to liquid ratio, time, stirring speed, temperatiir, and acid concentration have been selected as parameters. The optimum process contions were found to be reaction temperatiir 65°C, acid concentration 3 M, solid to liquid ratio 0.1 (g.mL'1), reaction time of 48 (minute), stirring speed 700 (rpm).Under these optimum process conditions, the yield for the leaching of zinc, cadmiyum and lead was 97 %, 91 % and 0.052, respectively. 2002, 97 pages
Benzer Tezler
- Ağır metallerin ve radyasyonun biyolojik etkilerinin karşılaştırılması
The Comparison of the biological effects of heavy metals and radiation
GÜNEŞ DÖRTER KESKİN
- Bazı ağır metallerin (Hg++, Cd++, Cu++ ve Pb++) fasulye fidelerinin (Phaseolus vulgaris L. strike) gelişmesi üzerindeki etkilerinin biyokimyasal yönden araştırılması
An Investigation on the biochemical effect of some heavy metals(Hg++, Cd++, Cu++ and Pb++) on the growth of the bean seedlings (Phaseolus vulgaris L. strike)
FİKRİYE KIRBAĞ ZENGİN
- Maden sularındaki kurşun ve kadmiyum düzeylerinin araştırılması
Research for lead and cadmium levels in mineral water
HANDAN DÖKMECİ (LODOS)
Yüksek Lisans
Türkçe
1998
Eczacılık ve FarmakolojiGazi ÜniversitesiEczacılık Temel Bilimleri Ana Bilim Dalı
DOÇ. DR. AYSEL BAYHAN ÖKTEM
- Selenyumun adsorptif sıyırma voltametrisi ve diferansiyel puls polarografisi ile tayini için yöntem geliştirilmesi
Adsorptive stripping voltammetric and differantial pulse polarograpmc determination of selenium
RECAİ İNAM