Geri Dön

Bulk-Fill kompozit rezinlerin süt ve daimi dişlerdeki radyoopasitelerinin değerlendirilmesi

Evaluation of the radiopacity of Bulk-Fill composite resins in primary and permanent teeth

  1. Tez No: 989711
  2. Yazar: ZEYNEP TUĞRAN
  3. Danışmanlar: DOÇ. DR. CANAN BAYRAKTAR NAHİR
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Tokat Gaziosmanpaşa Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Pedodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu tez çalışması, farklı materyal içeriğine sahip olan altı farklı bulk-fill kompozit rezin materyalinin radyoopasite değerlerinin süt ve daimi diş mine ve dentin yapılarıyla karşılaştırmak amacıyla yapılmıştır. Bu tez çalışmasında SDR Plus Bulk-Fill Flowable, Estelite Flowable Bulk-fill, 3M Filtek Bulk-Fill Flowable Restorative, Beautifil Bulk Flowable, Xtra Fill ve Simplishade Bulk-fill kompozit rezin materyalleri incelenmiştir. Her bir materyal 1, 2 ve 4 mm kalınlıklarda hazırlanmış; süt ve daimi dişlerden elde edilen mine ve dentin örnekleri ile birlikte dijital radyografi yöntemi kullanılarak görüntülenmiştir. Radyografik görüntülerdeki ortalama gri değerler Image J yazılımı ile ölçülmüş ve alüminyum step wedge yöntemi kullanılarak mmAl cinsinden radyoopasite değerleri hesaplanmıştır. Verilerin analizi IBM SPSS v23 ile yapılmış, normal dağılıma uygunluk Shapiro-Wilk Testi ile incelenmiştir. Diş/Materyal ve kalınlıklara göre normal dağılım göstermeyen verilerin karşılaştırılmasında Robust ANOVA kullanılmış ve çoklu karşılaştırmalar Holm Düzeltmeli Robust t Testi ile incelenmiştir. Anlamlılık düzeyi p<0,05 olarak alınmıştır. Analiz sonuçları, hem materyal türünün hem de uygulama kalınlığının radyoopasite üzerinde istatistiksel olarak anlamlı etkiye sahip olduğunu göstermiştir (p<0,001). Ayrıca diş/materyal - kalınlık etkileşiminin de oldukça yüksek bir etki büyüklüğüne sahip olduğu saptanmıştır (kısmi eta kare = 0,999). Çalışma bulguları, bulk-fill kompozit rezin materyallerinin radyoopasite değerlerinin farklı uygulama kalınlığı, seçilen materyal türü ve materyal-kalınlık etkileşimine bağlı olarak değiştiğini göstermiştir. Bu doğrultuda, klinik uygulamalarda restoratif materyal seçimi yapılırken materyalin radyoopasite özelliklerinin, uygulama kalınlığı ve diş dokusuyla olan ilişkisi göz önünde bulundurulmalı; elde edilen bulguların tanısal doğruluk ve restorasyon takibi açısından yol gösterici olabileceği düşünülmektedir.

Özet (Çeviri)

This thesis aimed to compare the radiopacity values of six bulk-fill composite resin materials with different material compositions in relation to the enamel and dentin structures of primary and permanent teeth. The bulk-fill composite resins evaluated in this study were SDR Plus Bulk-Fill Flowable, Estelite Flowable Bulk-Fill, 3M Filtek Bulk-Fill Flowable Restorative, Beautifil Bulk Flowable, X-tra Fill, and Simplishade Bulk-Fill. Each material was prepared in thicknesses of 1, 2, and 4 mm and radiographed together with enamel and dentin samples obtained from primary and permanent teeth using a digital radiographic system. The mean gray values obtained from the radiographic images were measured using Image J software, and radiopacity values were calculated in terms of millimeters of aluminum (mmAl) by applying the aluminum step wedge method. Statistical analyses were performed using IBM SPSS version 23. Normality of data distribution was assessed using the Shapiro–Wilk test. For comparisons involving tooth/material types and thicknesses that did not show normal distribution, Robust ANOVA was applied, and multiple comparisons were conducted using the Holm-corrected robust t-test. The level of statistical significance was set at p < 0.05. The results demonstrated that both the type of material and the application thickness had a statistically significant effect on radiopacity (p < 0.001). In addition, the interaction between tooth/material type and thickness showed a very large effect size (partial eta squared = 0.999). The findings of this study indicate that the radiopacity values of bulk-fill composite resin materials vary depending on the applied thickness, the selected material type, and the interaction between material and thickness. In this regard, when selecting restorative materials for clinical applications, the material's radio-opacity properties, application thickness and relationship with dental tissue should be taken into consideration; it is thought that the findings obtained may be indicative in terms of diagnostic accuracy and restoration follow-up.

Benzer Tezler

  1. Süt dişlerinde bulk-fill kompozit rezinlerin mekanik özelliklerinin karşılaştırmalı değerlendirilmesi

    Comparative Evaluation of Mechanical Properties of Bulk-Fill Composite Resins in Primary Teeth

    GÖKÇE ŞAHİN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiEskişehir Osmangazi Üniversitesi

    Çocuk Diş Hekimliği Ana Bilim Dalı

    PROF. DR. ŞULE BAYRAK

  2. Süt molar dişlerin mod kavitelerinde farklı tip kompozit rezinlerin stres dağılımlarının incelenmesi

    Investigation of stress distribution of different types of composite resinsin mod cavities of primary molar teeth

    SELİN ACAR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiOrdu Üniversitesi

    Pedodonti Ana Bilim Dalı

    PROF. DR. ÇİĞDEM GÜLER

  3. Fiber ile güçlendirilmiş kompozit rezinlerin fiziksel özelliklerinin ve bağlanma dayanımlarının değerlendirilmesi

    Evaluation of physical properties and bond strength of fiber reinforced composite resins

    CANSU DERDİYOK

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiSivas Cumhuriyet Üniversitesi

    Çocuk Diş Hekimliği Ana Bilim Dalı

    PROF. DR. FATİH ÖZNURHAN

  4. Kütlesel olarak yerleştirilebilen restoratif materyallerin klinik ve radyolojik olarak değerlendirilmesi

    Clinical and radiological evaluation of bulk-fill restorative materials

    HAYRİ AKMAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2016

    Diş HekimliğiSelçuk Üniversitesi

    Pedodonti Ana Bilim Dalı

    PROF. DR. GÜL TOSUN

  5. Evaluation of the surface roughness and microhardness of three bulk fill nonflowable resin composites in comparison to one conventional resin compsite after polishing with different polishing systems

    Farklı cilalama işlemlerinden sonra üç akışkan olmayan bulk fill kompozit rezin ile geleneksel kompozit rezinin karışlaştırmalı olarak yüzey pürüzlülüğü ve mikrosertliğin değerlendirilmesi

    OSAMA SHENEEB

    Yüksek Lisans

    İngilizce

    İngilizce

    2015

    Diş HekimliğiYeditepe Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    YRD. DOÇ. DR. MUSTAFA ERSOY

    PROF. ASIM MÜBİN SOYMAN