Geri Dön

Servikal dilatasyon ölçümü için giyilebilir teknolojik bir cihazın geliştirilmesi ve kullanım etkinliğinin değerlendirilmesi

Development of a wearable technological device for cervical dilation measurement and the evaluation of its use effectiveness

  1. Tez No: 976458
  2. Yazar: PELİN BAŞKURT
  3. Danışmanlar: DOÇ. DR. SELDA İLDAN ÇALIM
  4. Tez Türü: Doktora
  5. Konular: Ebelik, Midwifery
  6. Anahtar Kelimeler: Travay takibi, vajinal tuşe, vajinal muayene, servikal dilatasyon, giyilebilir teknoloji
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Manisa Celal Bayar Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ebelik Ana Bilim Dalı
  12. Bilim Dalı: Ebelik Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Serviksin dilatasyon ölçümü için giyilebilir teknolojik bir cihazın geliştirilmesi ve geliştirilen cihazın kullanım etkinliğini değerlendirmek amaçlanmıştır. Gereç ve Yöntem: Araştırmada, nitel ve nicel yöntemlerin birlikte kullanıldığı karma yöntem araştırmalarından açımlayıcı sıralı desen yaklaşımı kullanılmıştır. Araştırma üç aşamadan oluşmuştur. Birinci aşama, cihazların geliştirilmesi ve tekrar testlerin yapılması, ikinci aşama ebelerin servikal dilatasyon ölçüm cihazını kullanımı üçüncü aşama ise ebelerin servikal dilatasyon ölçüm cihazı ile ilgili geri bildirimlerinin alınmasını içermektedir. Veri toplama aracı olarak araştırmanın birinci aşamasında tekrarlanabilirlik testleri kayıt formu, ikinci aşamasında vajinal muayene uygulama değerlendirme formu, üçüncü aşamasında ebe tanıtım ve geri bildirim formu ve ebe görüşme formu kullanılmıştır. Araştırma Eylül 2023- Mart 2025 tarihleri arasında yürütülmüştür. Araştırmanın etik onayı Manisa Celal Bayar Üniversitesi Tıp Fakültesi Sağlık Bilimleri Etik Kurulundan alınmıştır. Servikal dilatasyonun değerlendirilmesi Manisa Celal Bayar Üniversitesi Sağlık Bilimleri Fakültesi simülasyon laboratuvarında yapılmıştır. Araştırmaya katılan ebeler kartopu örneklem yöntemi ile belirlenmiştir. Araştırmanın nicel verilerinde 30 ebe, görüşme yapılarak alınan nitel verilerde 22 ebe araştırmanın örneklemini oluşturmuştur. Nicel verilerin analizinde SPSS Statistics 25 programı kullanılarak sayı ve yüzdelik dağılımlar, Independent Sample Test, karşılaştırmalı testler için t testi kullanılmıştır. Nitel veriler, MAXQDA veri analiz programı kullanılarak çözümlenmiş olup tema, alt tema ve kodlar oluşturulmuştur. Bulgular: Geliştirilen servikal dilatasyon ölçüm cihazının doğruluk yüzdesi %99,22 bulunmuştur. Ebelerin servikal dilatasyonu değerlendirmeleri sırasında cihazın gösterdiği servikal dilatasyon değerlerinin doğruluk yüzdesi %96,66 görülmüştür. Ebelerin %93,3'ü geri bildirimlerinde servikal dilatasyon ölçüm cihazının klinikte tercih edilebileceğini ve vajinal muayene yapmanın rahat olduğunu, %90'ı vajinal muayene sırasında kolaylık sağladığını ifade etmişlerdir. Servikal dilatasyon ölçüm cihazına yönelik yapılan görüşmelerde elde edilen nitel veriler ile üç tema (Uygulama deneyimi, cihazın kullanım gerekliliği, görüş ve öneriler) ve sekiz alt tema (Ebelerin duygu ve düşünceleri, kullanım süreci, kişisel olarak, mesleki olarak, gebelere yönelik, eğitime yönelik, cihazın geliştirilmesine yönelik ve kullanım alanlarına yönelik) etiketi belirlenmiştir. Sonuç: Servikal Dilatasyon Ölçüm Cihazının doğruluk oranının yüksek olduğu, ebeler tarafından kullanıldığında etkin olduğu bulunmuştur. Klinik ve eğitim alanında cihazın kullanılmasının ve farklı alanlarda kullanılarak sonuçlarına bakılması önerilmektedir.

Özet (Çeviri)

Objective: The aim is to develop a wearable technological device for dilatation measurement of the cervix and to evaluate the effectiveness of the device. Materials and Method: The study utilized an exploratory sequential design approach, which is one of the mixed method studies in which qualitative and quantitative methods are used together. The research consisted of three stages. The first stage included the development of the devices and retesting, the second stage included midwives' use of the cervical dilatation measurement device and the third stage included midwives' feedback on the cervical dilatation measurement device. Repeatability tests recording form in the first stage, vaginal examination application evaluation form in the second stage, midwife introduction and feedback form and midwife interview form in the third stage were used as data collection tools. The study was conducted between September 2023 and March 2025. Ethical approval was obtained from Manisa Celal Bayar University Faculty of Medicine, Health Sciences Ethics Committee. The evaluation of cervical dilatation was performed in the simulation laboratory of Manisa Celal Bayar University Faculty of Health Sciences. Midwives participating in the study were determined by snowball sampling method. The sample consisted of 30 midwives in the quantitative data and 22 midwives in the qualitative data obtained through interviews. In the analysis of quantitative data, number and percentage distributions, Independent Sample Test and t test were used using SPSS Statistics 25 program. Qualitative data were analyzed using MAXQDA data analysis program and themes, sub-themes and codes were created. Results: The accuracy of the developed cervical dilatation measurement device was 99.22%. The accuracy of the cervical dilatation values shown by the device during midwives' evaluation of cervical dilatation was 96.66%.In their feedback, 93.3% of the midwives stated that the cervical dilatation measurement device could be preferred in the clinic and that it was comfortable to perform vaginal examination, and 90% stated that it provided convenience during vaginal examination.With the qualitative data obtained from the interviews about the cervical dilatation measurement device, three themes (implementation experience, necessity of using the device, opinions and suggestions) and eight sub-themes (midwives' feelings and thoughts, usage process, personally, professionally, for pregnant women, for education, for the development of the device and for the areas of use) were labeled. Conclusion: Cervical Dilatation Measurement Device was found to have a high accuracy rate and to be effective when used by midwives. It is recommended to use the device in the clinical and educational field and to look at the results by using it in different areas.

Benzer Tezler

  1. Erken doğumu öngörmede yeni ikinci trimester ultrason skorlama sistemi

    New second trimester ultrasound scoring system in prediction preterm labor

    ELİF CANSEVEN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Kadın Hastalıkları ve DoğumSağlık Bilimleri Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    DOÇ. DR. BURCU DİNÇGEZ

  2. Normal doğum için kullanılan farklı analjezik yöntemlerin anne ve fetus üzerine etkilerinin incelenmesi

    The effects of different analgesic methods used for the normal delivery to the fetus and mother

    GÜLÇİN BABAOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2015

    Anestezi ve ReanimasyonHacettepe Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. BANU KILIÇASLAN

  3. Doğum indüksiyon başarısını öngörmede ultrasonografik olarak uterus ve serviks arasındaki açıların değerlendirilmesi, bishop skoru ve servikal uzunluk ile prediktivitelerinin kıyas edilmesi

    Evaluation of the angles between the uterus and cervix by ultrasonography in predicting the success of labor induction: Comparison of their predictive value with the bishop score and cervical length

    AYŞE GİZEM YILDIZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Kadın Hastalıkları ve DoğumSağlık Bakanlığı

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    PROF. DR. ALİ TURHAN ÇAĞLAR

  4. Doğum eylemindeki gebelere yapılan transperineal ultrasonun doğum komplikasyonlarını öngörmesindeki başarısının değerlendirilmesi

    Evaluation of the success of transperineal ultrasound performed on pregnant women in labor in predicting birth complications

    CELAL NACAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Kadın Hastalıkları ve DoğumSağlık Bilimleri Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    DOÇ. DR. DENİZ KULAKSIZ

  5. Doğum eyleminin sonuçlarını öngörmede intrapartum transperineal ultrasonografinin yeri

    The role of intrapartum transperineal ultrasonography to predict the results of labor outcome

    ESRA KARTAL

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2020

    Kadın Hastalıkları ve DoğumSağlık Bilimleri Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    DOÇ. DR. EMİN ÜSTÜNYURT