Hatay'da betonarme mevcut bir okul binasının maraş depremi etkisialtında izolatörlü davranışı

Earthquake isolated behavior of an existing reinforced concrete school building in Hatay under the impact of maraş earthquake

  1. Tez No: 970311
  2. Yazar: BURAK ÇİFTÇİ
  3. Danışmanlar: DOÇ. DR. HALİL NOHUTCU
  4. Tez Türü: Yüksek Lisans
  5. Konular: İnşaat Mühendisliği, Civil Engineering
  6. Anahtar Kelimeler: Sismik yalıtım, İzolatör, Seismic insulation
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Manisa Celal Bayar Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Yapı Ana Bilim Dalı
  12. Bilim Dalı: İnşaat Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Türkiye, tarihsel süreçte birçok yıkıcı depreme maruz kalmıştır. Bu depremlerden biri de 6 Şubat 2023 tarihinde meydana gelen ve merkez üssü Kahramanmaraş olan, büyüklüğü 7.7 Mw olarak ölçülen depremdir. Bu sarsıntı, yapılarda büyük oranda hasara yol açmış, can kayıpları ve altyapı sorunlarıyla birlikte birçok binanın kullanılamaz hale gelmesine neden olmuştur. Depremden en fazla etkilenen yapılardan biri de eğitim kurumları olmuştur. Hatay ilinde bulunan ve ciddi yapısal zarar gören bir okul binası bu çalışmanın inceleme konusu olarak seçilmiştir. Söz konusu yapının deprem etkisi altındaki performansı, SAP2000 yazılımı ile üç boyutlu modellenmiş ve zaman tanım (time history) alanında doğrusal olmayan (nonlinear) analiz yöntemiyle değerlendirilmiştir. Analiz kapsamında; güçlendirme yapılmamış mevcut yapı modeli, sadece perde eklenerek güçlendirilmiş model ve perde+sismik izolatör uygulanan model olmak üzere üç farklı durum göz önünde bulundurulmuştur. Performans analizi sonuçları, TBDY-2018'e göre, gerçek deprem kayıtları yapıya uygulandığında güçlendirilmemiş modelin çökmeye maruz kaldığı, perde duvar eklenerek güçlendirilen modelin ise kesintisiz kullanım aşamasında olduğu FEMA356 ve TBDY-2018'e göre tespit edilmiştir. Yine sismik izolatör kullanılan modelin Kesintisiz Kullanım durumunda kaldığı gözlemlenmiştir. Farklı modelleri için doğal titreşim periyodu, kat deplasmanları, taban kesme kuvvetleri ve kolonlarda meydana gelen iç kuvvetler detaylı bir şekilde değerlendirilmiştir. İzolatör kullanmak binaya gelen yükleri ve bina kat ötelemelerini düşürür bu da izolatör kullanmamız gerektiğini göstermektedir. ANAHTAR KELİMELER Deprem Hasarı, Deprem, Güçlendirilmiş Bina, Sismik İzolatör, Doğrusal Olmayan Analiz, Yapı Deprem Analizi, Betonarme Perde, Deprem Performans Analizi.

Özet (Çeviri)

One of the most devastating earthquakes that Turkey has experienced was the Kahramanmaraş earthquake, which occurred on February 6, 2023. This earthquake, with a magnitude of 7.7 Mw, caused a high number of casualties and significant damage to buildings and infrastructure in general. Among the damaged structures, many school buildings in the region were also affected. In this study, a school building in Hatay province that suffered severe damage was selected for performance analysis. As part of the study, the structural model of the school was created and analyzed using the SAP2000 software with linear analysis methods defined in the time domain. The performance of the building was evaluated under four different conditions: the original unstrengthened model, a model with existing shear walls, a model strengthened by adding new shear walls, and shear walls + seismic isolation systems. According to TBDY-2018, when real earthquake ground motions were applied to the structure, the unretrofitted model was found to experience collapse. In contrast, the retrofitted model with added shear walls achieved the Immediate Occupancy performance level, as identified in accordance with both FEMA 356 and TBDY-2018. Similarly, the model incorporating seismic isolators was also observed to remain within the Immediate Occupancy performance level. For the different structural models, the fundamental natural period, story displacements, base shear forces, and internal forces developed in the columns were comprehensively evaluated. The use of seismic isolators reduces the loads transmitted to the structure as well as the interstory drifts, which demonstrates the necessity of employing isolation. KEY WORDS Horizontal earthquake ground motion, Seismic Isolator, earthquake, Strengthened Building, Earthquake Damage, Linear Analysis, Nonstructural Analysis, Structural Performance Analysis, Reinforced Concrete Shear Wall.

Benzer Tezler

  1. İzolatörlü ve betonarme perde ile güçlendirilmiş bir yapının deprem etkilerinin karşılaştırılması

    Comparison of the seismic effects on a structure reinforced with concrete shear walls and equipped with seismic isolators

    SAYFULDEEN ALI ABOUSALAH ABOUSALAH

    Yüksek Lisans

    Türkçe

    Türkçe

    2025

    İnşaat MühendisliğiManisa Celal Bayar Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    DOÇ. DR. HALİL NOHUTCU

  2. Deprem bölgelerindeki prefabrike betonarme endüstri binaların yapısal sistemlerinin değerlendirilmesi ve eğimli çatı kirişleri için alternatif tasarımlar

    Overview of structural systems of prefabricated/precast concrete industrial buildings in seismic regions and alternative designs for sloped roof beams

    SELİN KOCA

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Mimarlıkİstanbul Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    PROF. DR. OĞUZ CEM ÇELİK

  3. Samandağ'ın (Hatay) beşeri ve iktisadi coğrafyası

    The human and economic geography of Samandag district (Hatay)

    VEYSEL KUŞÇU

    Doktora

    Türkçe

    Türkçe

    2008

    CoğrafyaFırat Üniversitesi

    Coğrafya Ana Bilim Dalı

    DOÇ. DR. HARUN TUNÇEL

  4. 06 şubat kahramanmaraş depreminin betonarme karkas yapılarda etkisinin incelenmesi ve değerlendirilmesi: Diyarbakır örneği

    Investigation and evaluation of the effects of the 6 february kahramanmaraş earthquake on reinforced concrete frame structures:the case of Diyarbakir

    SEDAT ASLAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2026

    MimarlıkDicle Üniversitesi

    Mimarlık Ana Bilim Dalı

    DOÇ. DR. NURSEN IŞIK

  5. Düşey taşıyıcı elemanlardaki hasarın malzeme mekanik özelliklerine etkisinin incelenmesi

    Examination of the effect of damage to vertical carrier elements on material mechanical properties

    SUAT TORUN

    Yüksek Lisans

    Türkçe

    Türkçe

    2025

    İnşaat MühendisliğiKonya Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. MEHMET KAMANLI