Rutin IVF laboratuvarında kullanılan plastik malzemelerin sperm üzerindeki toksik etkileri
Toxic effects of plastic materials used in routine IVF laboratory on sperm
- Tez No: 962735
- Danışmanlar: PROF. DR. TÜLAY İREZ
- Tez Türü: Yüksek Lisans
- Konular: Histoloji ve Embriyoloji, Histology and Embryology
- Anahtar Kelimeler: IVF, plastik toksisitesi, sperm motilitesi, semen kabı, Falcon tüpü, HSMA, MEA, bisfenol A, Plastikler, Sperm, Sperm mobilitesi, Sperma özellikleri, Toksisite, Tüp bebek, IVF, plastic toxicity, sperm motility, semen collection cup, Falcon tube, human sperm motility assay, bisphenol A, Plastics, Spermatozoa, Sperm mobility, Sperm characteristics, Toxicity, Test tube baby
- Yıl: 2025
- Dil: Türkçe
- Üniversite: İstanbul Yeni Yüzyıl Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Histoloji ve Embriyoloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
IVF laboratuvarında kalite kontrolü'nün önemi son yıllarda yapılan çalışmalar ile kanıtlanmıştır. Bu çalışma, rutin IVF laboratuvarında kullanılan semen toplama kabı ve sperm hazırlamada kullanılan Falcon tüpü'nün insan spermi üzerindeki olası toksik etkilerini incelemeyi amaçlamaktadır. Çalışmaya 2024-2025 yılları arasında Medistate Kavacık Hastanesi IVF Merkezi'ne semen analizine başvuran ve normozoospermik özellikler gösteren toplam 67 erkek'te semen örnekleri dahil edildi. Her bir taze semen örneği, likefaksiyon sonrası DSÖ, 2021 kriterlerine göre rutin analiz edildi başlangıç sperm parametreleri belirlendi. Ardından örnekler iki gruba ayrıldı: bir grup örnek orijinal semen kabında, diğer grup örnek Falcon 2095 konik tüplerinde 24 saat 37°C'de inkübe edildi. 24 saatlik maruziyet sonunda sperm motilitesi ve vitalitesi bakıldı. Elde edilen verilerde, %30'dan fazla motilite veya canlılık azalması“toksik etki”kriteri olarak kabul edildi. İstatistiksel analizde eşleştirilmiş örnekler spss istatistik programı kullanılarak t-testi ve ki-kare testleri kullanılarak başlangıç ve maruziyet sonrası değerler karşılaştırıldı (p<0.05 anlamlı kabul edildi). Bulgular: Semen kabında bekletilen örneklerde 24 saat sonunda sperm hareketliliğinde belirgin bir düşüş görüldü. Toplam motilite ortalama %45.2'den %26.5'e geriledi ve bu azalma istatistiksel olarak anlamlıydı (p<0.001). Vitalite oranı da %87.7'den %78.6'ya düştü (p<0.01). İncelenen 40 semen kabı örneğinin 17'sinde (%42.5) toplam motilitede %30'dan fazla azalma saptandı. Buna karşın, Falcon tüplerinde bekletilen yıkanmış sperm örneklerinde toplam motilite başlangıçta ortalama %60.0 iken 24 saat sonunda %57.2 olarak bulundu; aradaki küçük fark istatistiksel olarak anlamlı olsa da (%2-5'lik düşüş, p<0.005), klinik açıdan minimaldi. Vitalite düşüşü anlamsız bulundu. (%89.7'den %86.9). Falcon grubundaki 27 örnekten yalnızca 1'inde (%3.7) motilitede %30'dan fazla azalma gözlendi. Bulgular, semen toplama kaplarının sperm motilitesi üzerinde olumsuz etkiler gösterebildiğini, Falcon tüplerinin ise görece daha güvenli olduğunu ortaya koydu. Sonuç: Rutin IVF laboratuvarında kullanılan bazı plastik malzemelerin, özellikle semen toplama kaplarının, sperm motilitesi üzerinde toksik etki potansiyeli taşıyabileceği deneysel olarak HSMA testi ile gösterilmiştir. Bu çalışma, IVF süreçlerinde plastik kaynaklı risklere dikkat çekerek, kalite kontrol önemini açıklamaktadır.
Özet (Çeviri)
The importance of quality control in in vitro fertilization (IVF) laboratories has been demonstrated by studies conducted in recent years. This study aims to investigate the potential toxic effects of the semen collection container used in routine IVF laboratories and the Falcon tube employed in sperm preparation on human sperm. A total of 67 men who applied to Medistate Kavacık Hospital IVF Center for semen analysis between 2024 and 2025 and exhibited normozoospermic characteristics were included in the study. Each fresh semen sample was routinely analyzed according to the WHO 2021 criteria after liquefaction, and initial sperm parameters were determined. The samples were then divided into two groups: one group was incubated in the original semen container, and the other group was incubated in Falcon 2095 conical tubes at 37 ° C for 24 hours. Sperm motility and vitality were examined at the end of the 24- hour exposure. A decrease in motility or vitality of more than 30% was considered a criterion for“toxic effect. ”In the statistical analysis, paired samples were compared using the SPSS statistical program, employing t- tests and chi- square tests for initial and post- exposure values (p < 0. 05 was considered significant). A significant decrease in sperm motility was observed in samples kept in semen containers after 24 hours. Total motility decreased from an average of 45. 2% to 26. 5%, and this decline was statistically significant (p< 0. 001). The vitality rate also reduced from 87. 7% to 78. 6% (p< 0. 01). In 17 of the 40 semen container samples examined (42. 5%), a decrease of more than 30% was detected in total motility. In contrast, in washed sperm samples kept in Falcon tubes, total motility was recorded at 60. 0% at the beginning and 57. 2% at the end of 24 hours; however, the slight difference was statistically significant (a 2-5% decrease, p< 0. 005), but it was clinically minimal. The decline in vitality was found to be insignificant (from 89. 7% to 86. 9%). Only 1 out of 27 samples ( 3.7%) in the Falcon group showed a decrease in motility of more than 30%. The findings revealed that semen collection containers may adversely affect sperm motility, while Falcon tubes are relatively safer. It has been experimentally shown with the HSMA test that some plastic materials used in routine IVF laboratories, particularly semen collection containers, may pose a potential toxic effect on sperm motility. This study highlights the risks associated with plastic in IVF processes and emphasizes the significance of quality control.
Benzer Tezler
- Analysis of sperm cytoplasmic mRNA content with special reference to the storage temperature and its possible impact on early embryonic development
Farklı saklama sıcaklığına bağlı olarak spermatozoonlarda sitoplazmik mRNA içeriğindeki değişimlerin erken embriyonik gelişim üzerine muhtemel etkileri
MAİA ÖZDEMİR
Yüksek Lisans
İngilizce
2021
Histoloji ve EmbriyolojiAydın Adnan Menderes ÜniversitesiHistoloji ve Embriyoloji Ana Bilim Dalı
PROF. DR. ALPASLAN GÖKÇİMEN
- Kan ve follikül sıvısında antioksidan (melatonin,homosistein) seviyeleri arasında farklılıklar var mıdır? ın vıtro fertilizasyon (IVF) başarısı üzerine etkilerinin araştırılması
Are there differences between antioxidant (melatonin, homocysteine) levels in blood and follicle fluid? investigation of their effects on in vitro fertilization (İVF) success
İSMET ERİNÇ SALMAN
Tıpta Uzmanlık
Türkçe
2024
Kadın Hastalıkları ve DoğumSağlık Bilimleri ÜniversitesiKadın Hastalıkları ve Doğum Ana Bilim Dalı
PROF. DR. MUSTAFA ÖZTÜRK
- Erkek bireylerin açıklanamayan infertilitelerinde tiyoredoksin mekanizması ve testis- ifade protein 101 düzeyleri
Thioredoxine mechanisms and testis- expressed protein 101 levels in unexplained infertil men individuals
FATMA ZEHRA ERBAYRAM
Yüksek Lisans
Türkçe
2018
BiyokimyaSelçuk ÜniversitesiTıbbi Biyokimya Ana Bilim Dalı
DOÇ. DR. ESMA MENEVŞE
- Eser elementlerin yol açtığı dna hasarlarının seminal plazma ve sperm kromatin yapısı üzerine etkisinin tek hücre jel elektroforez (Comet assay) yöntemi ile analizi
The analysis of the effects of the dna damage caused (induced) by the trace elements on seminal plasma and sperm chromatine structure by single cell gel electrophoresis (Comet assay)
PINAR ALTINER
- Ferula Elaeochytris Korovin (çakşır) kökü ekstresinin insan sperm parametrelerine etkisinin in vitro olarak araştırılması
In vitro investigation of the effects of Ferula Elaeochytris Korovin (çakşir) root extract on human sperm parameters
ZEYNEP HAYIRLIOĞLU
Doktora
Türkçe
2025
Histoloji ve EmbriyolojiSelçuk ÜniversitesiHistoloji ve Embriyoloji Ana Bilim Dalı
PROF. DR. ENDER ERDOĞAN