Basınç sensörü kontrolünde cila sistemlerinin rezin kompozitin yüzey şekli, pürüzlülüğü, parlaklığı ve hacim kaybı üzerine etkisi
The effect of pressure-regulated polishing systems on surface topography, roughness, gloss, and volume loss of resin composites
- Tez No: 950125
- Danışmanlar: PROF. DR. CAFER TÜRKMEN
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Uygulama kuvveti, büyütme, cila sistemleri, pürüzlülük, boyutsal farklılık, parlaklık, Application force, magnification, polishing systems, roughness, dimensional change, gloss
- Yıl: 2025
- Dil: Türkçe
- Üniversite: Marmara Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu in vitro çalışmada, cila prosedüründe klinisyen tecrübesi, büyütme kullanımı, uygulama kuvveti ve cila sistemlerinin; yüzey pürüzlülüğü, parlaklığı ve boyutsal farklılık üzerine etkileri karşılaştırmalı olarak değerlendirilmiştir. Gereç ve Yöntem: Çalışmada nanohibrit rezin kompozit olan Neo Spectra ST (Dentsply Sirona) A2 rengi kullanıldı. Bu rezin kompozitten anterior diş morfolojisine sahip hazır silikon kalıp kullanılarak aynı kalınlık ve boyutlarda 150 adet örnek hazırlandı. Örnekler, klinisyen tecrübesi ve uygulama kuvvetine göre üç ayrı gruba ayrıldı. İlk iki grupta kuvvet, tecrübeli ve tecrübesiz klinisyenler tarafından uygulanan kuvvet sabitlenmeden serbest olarak uygulandı; üçüncü grupta ise uygulama kuvveti ortalama 1 N olması hedeflenerek 0,8-1,2 N aralığında uygulandı. Uygulama sırasında kuvvet değerleri, basınç sensörlü ve kuvvet ayarlı bir fırçalama cihazı ile anlık olarak kaydedildi ve özel bir yazılım aracılığıyla dijital ortama aktarıldı. Tüm cila işlemleri büyütme kullanılarak ve kullanılmadan olmak üzere iki gözlem koşulunda gerçekleştirildi. Her koşulda beş farklı cila sistemi (n=5), aynı tip kompozit materyal üzerinde cilalandı. Bu gruplar; Sof-Lex Disk (3M ESPE, ABD), Enhance/PoGo (Dentsply Sirona, ABD), Lucida (DiaShine, Style İtaliona,ABD), Diacomp Twist Plus (EVE Ernst Vetter, Keltern, Almanya) ve Opti1Step (KavoKerr Corporation, ABD 3M, ABD) olarak belirlendi. Cila öncesi ve sonrası örneklerin profilometre ile yüzey pürüzlülüğü, glossmetre ile yüzey parlaklığı ölçüldü. Cila öncesi ve sonrası alınan taramalar Geomagic Control X programına aktarılarak iki veri arasındaki boyutsal farklılık değerlendirildi. Elde edilen veriler SPSS v23 (IBM) programı ile analiz edildi ve anlamlılık düzeyi p<0,05 olarak belirlendi. Bulgular: Uygulama kuvveti, Uygulama 2' de Uygulama 1 'e göre anlamlı derecede daha yüksek bulundu (p<0,001). Büyütme ve cila sistemi uygulama kuvveti üzerinde etkili bulundu (p<0,001). Yüzey pürüzlülüğü ve parlaklık üzerinde en belirleyici değişkenin kullanılan cila sistemi olduğu belirlendi, klinisyen tecrübesi ve büyütmenin etkisi istatistiksel olarak anlamlı bulunmadı (p>0,05). Cila sistemleri arasında, boyutsal farklılık değerleri açısından da anlamlı fark saptandı (p<0,001). Lucida cila sisteminin ortalama RMS değeri diğer tüm cila sistemlerinden anlamlı düzeyde farklıdır (p<0,05). Sonuç: Uygulama kuvveti; klinisyen tecrübesi, büyütme kullanımı ve cila sistemine bağlı olarak değişkenlik gösterdi. Yüzey özellikleri üzerinde en belirleyici etkenin cila sistemi olduğu, pürüzlülük ile parlaklık arasında ters yönlü bir ilişki bulunduğu görüldü. Kuvvet arttıkça boyutsal farklılığın arttığı saptandı.
Özet (Çeviri)
Objective: The present in vitro study was conducted with the objective of comparatively evaluating the effects of clinician experience, magnification use, application force and polishing systems on surface roughness, gloss and dimensional variation in the polishing procedure. Materials and Methods: The study utilised the Neo Spectra ST (Dentsply Sirona) A2 colour nanohybrid resin composite. A total of 150 samples of uniform thickness and size were prepared from the resin composite using a ready-made silicone mold with anterior tooth morphology. The samples were divided into three separate groups based on clinician experience and application force. In the first two groups, the application of force was executed without restraint by both experienced and inexperienced clinicians; in the third group, the application force was targeted to be an average of 1 N and applied within the range of 0.8–1.2 N. During the application process, force values were recorded in real-time using a pressure-sensing and forceadjustable brushing device and transferred to a digital format via specialized software. All polishing procedures were conducted under two observation conditions: with and without magnification. In each condition, five distinct polishing systems (n=5) were applied to the same type of composite material. The following groups were identified: Sof-Lex Disk (3M ESPE, USA), Enhance/PoGo (Dentsply Sirona, USA), Lucida (DiaShine, Style Italia, USA), Diacomp Twist Plus (EVE Ernst Vetter, Keltern, Germany), and Opti1Step (KavoKerr Corporation, USA 3M, USA). The surface roughness was measured using a profilometer, and the surface gloss was measured using a glossmeter before and after polishing. Subsequent to the polishing process, the scans were transferred to the Geomagic Control X program, and the dimensional discrepancies between the two sets of data were evaluated. The obtained data were analysed using SPSS v23 (IBM) software, with a significance level set at p<0.05. Results: The application force was significantly higher for Application 2 than for Application 1 (p < 0.001). Magnification and the polishing system were found to affect application force (p <0.001). The polishing system used was found to be the most significant variable affecting surface roughness and gloss; the effects of clinician experience and magnification were not statistically significant (p> 0.05). Significant differences were also detected between polishing systems in terms of dimensional difference values (p <0.001). The average RMS value of the Lucida polishing system differed significantly from the average values of all the other polishing systems (p <0.05). Conclusion: The application force varies depending on the experience of the clinician, the use of magnification and the polishing system. It has been observed that the polishing system has the greatest impact on surface properties and that there is an inverse relationship between roughness and gloss. It has also been determined that dimensional differences increase as force increases.
Benzer Tezler
- Endüstri 4.0 uygulamaları için piezorezistif akıllı basınç sensörü tasarımı ve geliştirilmesi
Piezoresistive smart pressure sensor design and development for industry4.0 applications
İBRAHİM TOY
Yüksek Lisans
Türkçe
2020
Elektrik ve Elektronik MühendisliğiNecmettin Erbakan ÜniversitesiElektrik-Elektronik Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ HAKKI SOY
- Turbocharger inlet temperature observer model for diesel internal
Dizel içten yanmalı motorlarda turboşarj giriş sıcaklığı izleyici modeli
ÖMER EREN
Yüksek Lisans
İngilizce
2018
Makine Mühendisliğiİstanbul Teknik ÜniversitesiMekatronik Mühendisliği Ana Bilim Dalı
PROF. DR. ATA MUGAN
- Hyperloop altyapı kapsülü geliştirilmesi
Hyperloop infrastructure capsule development
YEKTA YEŞİLYURT
Yüksek Lisans
Türkçe
2024
Makine Mühendisliğiİstanbul Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ HİKMET ARSLAN
- Comparison of three IPMSM sensorless position estimation methods through simulations and experiments
İç sabit mıknatıslı senkron motorlarda üç sensörsüz konum tahmini yönteminin simülasyonlar ve deneyler aracılığı ile karşılaştırılması
KAAN BAYKA
Yüksek Lisans
İngilizce
2014
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiKontrol ve Otomasyon Mühendisliği Ana Bilim Dalı
YRD. DOÇ. DR. ALİ FUAT ERGENÇ
- Elektronik kontrollü çekilir tip bir tarla pülverizatörünün geliştirilmesi
Development of towed type electronic controlled field atomizer
AHMET ERTUĞRUL BAY
Yüksek Lisans
Türkçe
2014
Elektrik ve Elektronik MühendisliğiKahramanmaraş Sütçü İmam ÜniversitesiElektrik-Elektronik Mühendisliği Ana Bilim Dalı
DOÇ. DR. MAHİT GÜNEŞ