Kuron köprü protezlerinde kullanılan metal alaşımlarının radyasyon ışınlarıyla karşılıklı etkileşimleri üzerine araştırmalar
Investigation of the interaction of metal allays used for crown and bridges with radiation rays
- Tez No: 86428
- Danışmanlar: PROF.DR. M. MURAT AYDIN
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Alaşımlar, Dental alaşımlar, Dental materyaller, Kronlar, Protezler ve implantlar, Radyasyon dozajı, Alloys, Dental alloys, Dental materials, Crowns, Prostheses and implants, Radiation dosage
- Yıl: 1999
- Dil: Türkçe
- Üniversite: İstanbul Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
7. ÖZET Metal-seramik restorasyonlarda kullanılan farklı metal ala şımlarının radyasyon dozuna etkilerinin incelenebilmesi amacıyla Degudent U, Bond-on 4 ve Duceranium metal alaşımlarından ve yine bu meta! alaşımları üzerine 1 mm. kalınlığında seramik pişirilme si suretiyle 6 grup halinde, her grupta 3'er adet olmak üzere top lam 18 adet örnek hazırlandı. Metal genişliğinin ve metal kalınlı ğının ışın dozuna etkisinin incelebilmesi amacıyla ise kalay meta li kullanılarak 0.5,1,2,3,4,5 mm. kalınlıklarında olmak üzere 6 adet 1x1 cm. genişliğinde, 6 adet ise 2.5x2.5 cm. genişliğinde top lam 12 örnek hazırlandı. Metal ve metal-seramik örneklerin değişik mesafelerdeki ışın absorbsiyonu ve geri saçılma ölçümleri iyon odası ve dansitomet- rik yöntemler yardımıyla, kalay örneklerin absorbsiyon ve geri sa çılma ölçümleri ise iyon odası yöntemiyle gerçekleştirildi. Elde edilen ölçüm değerleri ve birbirleri ile olan farkları ista tistiksel olarak analiz edildi. En yüksek geri saçılma değerleri metallerin atom numaralarıyla doğru orantılı olacak şekilde Degu dent U alaşımında tesbit edildi. En yüksek ışın absorbsiyonu ise Bond-on 4 alaşımında elde edildi. Metal kalınlığının ve genişliğinin geri saçılma üzerinde etkili olmadığı buna karşılık metal kalınlığı arttıkça absorbe edilen ışın miktarının arttığı bulundu. Yapılan elektron mikroskobu incelemesinde ise radyasyon ışınlarının metallerin yapılarında herhangi bir değişikliğe neden olmadıkları saptandı. 189
Özet (Çeviri)
8. SUMMARY We've planned to evaluate the effects of the different metal- ceramic alloys on the radiation dose in the first part of our study. Metal alloy samples of Degudent U, Bond-on 4 and Duceranium were casted and ceramic of 1 mm. thickness was baked on this al loys. In this way 18 samples were prepared, in 6 groups and each group having 3 samples. In the second part of the study the effect of the metal thickness and width on the radiation dose was inves tigated. 6 samples of tin in 1x1 cm. dimension and 6 samples of 2.5x2.5 cm. dimension, in various thickness of 0.5,1,2,3,4,5 mm. were casted. The absorption and backscatter radiation measurements of the metal and metal-ceramic samples at various distances were de termined using ion chamber and densitometric methods whereas the absorption and backscatter measurements of the thin samples were performed using ion chamber method. The results and the differences between the measurement values were statistically analysed. The highest backscatter radia tion value for the metals was determined in Degudent U alloy, in direct correlation with the atomic number. On the other hand the highest absorption was observed in Bond-on 4 alloy. Another find ing of our study was that the thickness and the width of the metal alloy had no effect on the backscatter radiation but there was an increase in the absorption dose as the metal thickness increased. Scanning electron microscope evaluation of the samples re vealed that the radiation rays had no effect on the metal struc ture. [90
Benzer Tezler
- Ağız içinde uygulanan kuron ve köprülerde kullanılan çeşitli maddelerin karşılıklı olarak mukayesesi
Başlık çevirisi yok
EMİNE ÖZTAN
Yüksek Lisans
Türkçe
1986
Diş HekimliğiMarmara ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. İLHAN ÇUHADAROĞLU
- Döküm dolgularda kullanılan değişik metal alaşımlarının mekanik ve elektrokimyasal özellikleri yönünden birbirleriyle karşılaştırılması
Başlık çevirisi yok
YAVUZ GÖMEÇ
Doktora
Türkçe
1990
Diş Hekimliğiİstanbul ÜniversitesiDiş Hastalıkları ve Tedavisi Ana Bilim Dalı
PROF.DR. HİKMET ÇAMLI
- Kron-köprü protezlerinde kullanılan akrilik ve kompozit resinlerle soy olmayan metal altyapı arasında oluşan mikrosızıntının değerlendirilmesi
Başlık çevirisi yok
ENGİN KOCABALKAN
Doktora
Türkçe
1993
Diş HekimliğiGazi ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. YAVUZ BURGAZ
- Prefabrike porselen diş kullanılan protezlerde ajuste edilen ve aşındırılan kısımların normal ve alüminus porselenlerle tamamlanması ve bitirilmesi üzerine araştırmalar
Başlık çevirisi yok
FÜGEN KESKİN
Doktora
Türkçe
1985
Diş Hekimliğiİstanbul ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. ERHAN AKIN
- Kron-köprü protezlerinde kıymetsiz metal alaşımı alt yapının rezin materyali ile bağlantısında elektrokimyasal dağlama ve silanla kaplama yöntemlerinin karşılaştırılması
Başlık çevirisi yok
PERVİN İMİRZALIOĞLU
Doktora
Türkçe
1991
Diş HekimliğiGazi ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. EROL DEMİREL