Geri Dön

Prefabrike porselen diş kullanılan protezlerde ajuste edilen ve aşındırılan kısımların normal ve alüminus porselenlerle tamamlanması ve bitirilmesi üzerine araştırmalar

Başlık çevirisi mevcut değil.

  1. Tez No: 80540
  2. Yazar: FÜGEN KESKİN
  3. Danışmanlar: PROF. DR. ERHAN AKIN
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental porselen, Reçine, Takma dişler, Dental porcelain, Resin, Dentures
  7. Yıl: 1985
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

40 ÖZET Total ve parsiyel protezlerde kullanılan prefabrike seramik dişlerin yanında kuron köprü protezlerinde faset olarak kullanılan seramik dişle - rin, gerekli durumlarda yapılan aşındırma ve kırılma sebebiyle eksik olan kısımların daha dirençli alüminus porselenlerle ilaveler yaparak, prefab rike dişler istenilen form ve renkte elde etmek için yapılan bu araştır - mada: Materyal olarak piyasada bulunan 3 ayrı firma tarafından yapılmış 24 adet prefabrike seramik diş kullanıldı. Prefabrike bu dişlere 2 ayrı alüminus porselen ilâve edildi. Elde edilen numuneler bu dişleri yapan firmalara göre 3 gruba ayrıldı. Elde. edilen miks fasetler üstünde histolojik ve mekanik deneyler ya pıldı. Preperatlar ışık ve elektron mikroskopları ile ayrı ayrı tetkik edildi. Mekanik deneylerde kırılma değerleri üç eksenli test presinde be lirlendi. Sonuç olarak piyasada bulunan prefabrike seramik dişlere alü - minus seramiklerden ilâveler yapılabileceği ortaya konuldu. Prefabrike diş alüminus porselenden ise; kaynaşma çok daha homojen olmakta kırılma değerleri ise çok yüksek değerler göstermektedir. Prefab rike diş feldispatik porselenden ise: alüminus seramik ilavesinden sonra histolojik kontrolde kaynaşma homojen olmamakta, birleşme hududunda ka - piller boşluklar meydana gelmektedir, kırılma değeri ölçülmesinde ise elde edilen değerler çok düşük olmaktadır. Feldispatik seramik dişlere yapılan alüminus seramik ilaveden sonra elde edilen kırılma değerleri gene de saf feldispatik dişlerdeki kırılma değerlerinden daha yüksek değerler göstermektedir. Normal atmosfer basıncında hazırlanmış feldispatik prefabrike dişle re vakumda pişirilen alüminus seramik ilave edilebileceği ortaya konulmuş tur.

Özet (Çeviri)

41 SUMMARY The prefabricated ceramic teeth used in the construction of total or partial dentures and prefabricated porcelain faceds used in crown and bridge restorations are usually eroded by the dentist to establish a good occlusal relationship or esthetics. These teeth can also be broken by several ways. In order to establish a desired form and colour for these broken or eroded teeth, we have added more resistant aluminous porcelain for the missing parts. In this investigation 24 teeth of three different types fabricated by several companies were utilized as samples. These prefabricated teeth were repaired by two different kinds of aluminous parcelain. The specimens were divided into three groups according to the different companies, histolojical and mechanical tests were made on these mixed faceds. The preperations were examined by day light microscope and electron micros - cope. The mechanical breakage values were evaluated by three axial testing press. It is estimated that the prefabricated porcelain teeth can be resto red by aluminous porcelain. When felspathic prefabricated porcelain teeth were restored with aluminous porcelain; the histologic examinations revealed that the bonding was not homogenous and the breakage values were found lower. If the prefabricated teeth were aluminous porcelain; the bonding with aluminous porcelain was homogenous and the breakage values were found higher. The breakage values of aluminous porcelain bonding to prefabricated felspat hic porcelain were found higher, than the breakage of pure felspathic non - bonded teeth. In this research it is estimated that air-fired prefabricated felspat hic porcelain teeth can be used together with vacuum-fired aluminous ceramics.

Benzer Tezler

  1. Prefabrike inşaatta uygulanan bazı birleşim detaylarının teorik ve deneysel olarak incelenmesi

    Başlık çevirisi yok

    İDRİS TEZCAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1989

    İnşaat MühendisliğiAnadolu Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. M. RUHİ AYDIN

  2. Prefabrike beton bileşenlerle yapımda hata, boyutsal sapma ve toleranslar

    Faults, dimensional deviations and tolerances in construction with prefabricated concrete components

    ATIF FATİH SAYAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1990

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    PROF.DR. EROL KULAKSIZOĞLU

  3. Prefabrike betonarme panellerin birleşim yeri sorunları

    The Problems of joints in precast concrete panels

    EMİNE ERCAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1992

    MimarlıkGazi Üniversitesi

    Mimarlık Ana Bilim Dalı

    DOÇ. DR. GÖNÜL UTKUTUĞ

  4. Prefabrike beton cephe elemanlarında yüzey oluşturma yöntemleri ve uygulama sorunları

    The Methods of surface formation and their aplication matters in the prefabricated concrete facade members

    MUSTAFA TOSUN

    Yüksek Lisans

    Türkçe

    Türkçe

    1992

    İnşaat MühendisliğiSelçuk Üniversitesi

    Mimarlık Ana Bilim Dalı

    PROF.DR. REŞAT ÖNGEN

  5. Prefabrike betonarme taşıyıcı sistemlerde birleşim noktalarınadaki deprem sorununun incelenmesi

    Başlık çevirisi yok

    ŞÜKRÜ PAKSOY

    Yüksek Lisans

    Türkçe

    Türkçe

    1993

    MimarlıkYıldız Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    DOÇ. DR. E. GÖRÜN ÖZŞEN