Geri Dön

Lityum disilikat kuronların Er: YAG lazer ile desimantasyonu sırasında oluşan pulpal ısı değişimlerinin ve debonding sürelerinin İn Vitro olarak incelenmesi

In Vitro investigation of debonding time of lithium disilicate crowns and pulpal heat changes during debonding with Er: YAG laser

  1. Tez No: 849538
  2. Yazar: TANSU ŞENDURUR
  3. Danışmanlar: DOÇ. DR. RİFAT GÖZNELİ
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Tam seramik, seramik kalınlığı, desimantasyon, ısı değişimi, lazer parametresi, All-ceramic, ceramic thickness, debonding, heat transmission, laser parameter
  7. Yıl: 2024
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Günümüzde estetik beklentilerin gittikçe artması ile tam seramik kuron sistemlerindeki gelişmeler de hız kazanmıştır. Tam seramik kuronların simantasyonunda adeziv simanlar kullanılmaktadır; herhangi bir sebeple sökülmesi gerektiği durumlarda yüksek bağlanma kuvvetinden dolayı desimantasyon işlemi oldukça zordur. Diş hekimliğinin birçok alanında kullanılan lazerler debonding işlemleri için de kullanılmaya başlanmıştır. Bu çalışmanın amacı, farklı kalınlıktaki lityum disilikat kuronların çıkarılma sürelerini ve lazer uygulaması sırasında pulpadaki ısı değişimini belirlemektir. Gereç ve Yöntem: 1mm, 1,5mm ve karma kalınlıkta 45 adet lityum disilikat kuron, ilgili çekilmiş insan üst birinci küçük azı dişlerine rezin siman ile yapıştırıldı. 24 saat önce simantasyonları tamamlanmış olan örneklerin desimantasyon işlemleri için Er:YAG lazer kullanıldı. Her kalınlık için lazer parametreleri sırasıyla 5W, 5,6W ve 5,9W (10 Hz) idi. Her örnek için çıkıncaya kadar geçen süre ve lazer uygulaması sırasında pulpada meydana gelen sıcaklık değişim değerleri kaydedildi. İstatistiksel değerlendirmeler One-way ANOVA varyans, Duncan ve Tamhane's T2 testleri (p<0,05) kullanılarak yapıldı ve anlamlılığın her grup içinde ve grup ayrımı yapılmadan incelenmesi için Pearson korelasyon katsayısı kullanıldı. Bulgular: Her kuron kalınlığı için uygun parametrelerde çıkarılma süreleri (dak:sn) şu şekilde bulunmuştur: 1mm kalınlığındaki kuronlar için 5W güçte 2:30 ile 4:45 arasında; 1,5mm kalınlığındaki kuronlar için 5,9W güçte 5:00 ile 11:15 arasında; karma kalınlıktaki kuronlar için 5,9W güçte 8:45 ile 15:00. Ayrıca pulpa odasındaki sıcaklık değişimlerinin hiçbir örnek için kritik değer olan 5,5°C'yi aşmadığı gözlemlenmiştir. Sonuç: Er:YAG lazer ışınlaması, kalınlığa göre uygun lazer parametreleri kullanıldığında tam seramik kuronların çıkarılmasında etkili ve güvenli bir yöntemdir.

Özet (Çeviri)

Objective: Since the removal of resin-luted all-ceramic restorations is a challenge, the use of Er: YAG lasers has become popular. The aim of this study was to determine the removal time of monolithic lithium disilicate crowns in different thicknesses and heat transmission to pulp using Er: YAG laser. Materials and Methods: Forty-five full-coverage monolithic lithium disilicate crowns in 1mm, 1.5mm, and mixed thickness were resin luted on relevant extracted human maxillary first premolars and subjected to Er:YAG laser irradiation for crown removal after 24h. Laser parameters for each thickness, respectively, were 5W, 5,6W, and 5,9W (10 Hz). The removal time and temperature change values were recorded for each sample. The statistical evaluations were performed using One-way ANOVA variance and post hoc Duncan and Tamhane's T2 tests (p<0.05),and the Pearson correlation coefficient was used to examine the significance within each group and without group discrimination. Results: All crowns were laser-debonded successfully. Removal time (min:sec) at the succeeding laser parameter for each group: between 2:30 and 4:45 at 5W power for 1 mm samples; between 5:00 and 11:15 at 5.9W power for 1.5 mm samples; between 8:45 and 15:00 at 5,9W power for samples in mixed thickness. Moreover, it was observed that the temperature changes in the pulp chamber did not exceed the critical value of 5,5°C for any sample. Conclusion: Er:YAG laser irradiation is an effective and safe method for removal of all-ceramic crowns when the laser parameters are appropriate to thickness.

Benzer Tezler

  1. Evaluation of wear characteristics and volumetric change in bi-layered hybrid PEEK/PEKK CAD-CAM implant supported fixed dental prostheses

    İki katmanlı hibrit PEEK/PEKK CAD-CAM implant destekli sabit protezlerde aşınma karakterleri ve hacimsel değişimlerinin değerlendirilmesi

    HUSAM HAJI BAKR

    Doktora

    İngilizce

    İngilizce

    2025

    Diş HekimliğiYeditepe Üniversitesi

    Sağlık Bilimleri Ana Bilim Dalı

    PROF. DR. ENDER KAZAZOĞLU

  2. Dijital ölçü yöntemlerinin protetik restorasyonların marjinal ve internal uyumlarına etkisinin değerlendirilmesi

    Dijital ölçü yöntemlerinin protetik restorasyonların marjinal ve internal uyumlarına etkisinin değerlendirilmesi

    MERVE BENLİ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. BİLGE GÖKÇEN RÖHLİG

  3. Preslenebilir zirkonya ile güçlendirilmiş lithium silikat kuronların marjinal uyum ve kırılma dayanımının İn Vitro karşılaştırılması

    In Vitro comparison of marginal fit and fracture strengt of pressable zirconia reinforced lithium silicate crowns

    FULYA GÜLENER

    Doktora

    Türkçe

    Türkçe

    2024

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. DEĞER ÖNGÜL

  4. Farklı materyallerden hazırlanan monolitik kuronların marjinal uyum ve kırılma dayanımlarının incelenmesi

    Investigation of the marginal fit and fracture strength of monolithic crowns made from different materials

    CANSU AYSER ALOSMAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiRecep Tayyip Erdoğan Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. ZEYNEP YEŞİL DUYMUŞ

  5. Farklı siman aralıklarında hazırlanan cad/cam monolitik kuronların kırılma direncinin değerlendirilmesi

    Evaluation of the fracture resistance of cad/cam monolithic crowns prepared in different cement thicknesses

    NURDAN POLAT SAĞSÖZ

    Doktora

    Türkçe

    Türkçe

    2015

    Diş HekimliğiAtatürk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. NURAN YANIKOĞLU