Geri Dön

Farklı siman aralıklarında hazırlanan cad/cam monolitik kuronların kırılma direncinin değerlendirilmesi

Evaluation of the fracture resistance of cad/cam monolithic crowns prepared in different cement thicknesses

  1. Tez No: 379370
  2. Yazar: NURDAN POLAT SAĞSÖZ
  3. Danışmanlar: PROF. DR. NURAN YANIKOĞLU
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Kırılma direnci, monolitik CAD-CAM kuronlar, siman aralığı, Bilgisayar destekli tasarım, CAD/CAM, Dental cementum, Dental stres analizi, Dental çimentolar, Kronlar, Cement thickness, fracture resistance, monolithic CAD/CAM crowns, Computer aided design, CAD/CAM, Dental cementum, Dental stress analysis, Dental cements, Crowns
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Atatürk Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Farklı Siman Aralıklarında Hazırlanan CAD/CAM Monolitik Kuronların Kırılma Direncinin Değerlendirilmesi Amaç: Bu çalışmada farklı siman aralıklarında hazırlanan CAD/CAM monolitik kuronların kırılma direnci değerlendirildi. Materyal ve metod: Üzerinde kuronların kırılacağı güdüklerin standardizasyonu için üst insan 1. küçük azı dişi uygun boyutlarda kesildi. Bu dişten ölçüler alındı ve güdükler hazırlandı. Güdük materyalini belirlemek için yapılan pilot çalışmada üç farklı materyal (Ni-Cr, epoksi rezin, dentin) değerlendirildi. Güdükler üzerinde feldspatik CAD/CAM seramik kuronlar hazırlandı, kırılma kuvveti uygulandı. Dentine yakın kırılma değeri gösteren epoksi rezin materyalinden güdükler hazırlandı. CEREC 4 CAD/CAM sisteminde 4 farklı monolitik bloktan (feldspatik cam seramik 1, rezin nano seramik 2, lityum disilikat 1 ve lösit içerikli seramik 1 çeşit), 3 farklı siman aralığında (30, 90, 150 µm) kuronlar freze edildi. Her bir siman aralığı için 7 ve bir kuron materyali için 21 olmak üzere toplam 105 örnek hazırlandı. Kuronlar tek tip self adeziv rezin siman ile simante edildikten 1 saat sonra test yapılıncaya kadar 37°C' de 1 hafta bekletildi. Prepare edilmemiş doğal dişler kontrol grubu olarak kullanıldı. Kırılma direncini belirlemek için başlık hızı 1 mm/dk olan universal test cihazı kullanıldı. Kuvvet, kuronların santral oluğuna uygulandı. Sonuçlar Newton olarak kaydedildi. Bulgular: Veriler one way ANOVA ve iki faktörlü etkileşim modelleme testi (p<0.001) ile değerlendirildi. CAD/CAM monolitik kuronların kırılma direnci arasında istatistiksel olarak önemli farklılık bulunurken (p<0.001), siman aralıklarının kırılma direnci üzerine etkisinin istatistiksel olarak önemli olmadığı görüldü. (p>0.001) Sonuç: En yüksek kırılma direnci değeri IPS e.max CAD'de (1390.327 N), en düşük değer IPS Empres CAD'de (787.988 N) bulundu. 30, 90 ve 150 µm olarak belirlenen siman aralıklarında ise kırılma direnci değerlerinin benzer olduğu görüldü.

Özet (Çeviri)

Evaluation of the Fracture Resistance of CAD/CAM Monolithic Crowns Prepared In Different Cement Thicknesses Aim:In this study, the fracture resistance of CAD/CAM monolithic crowns prepared in different cement thicknesses was evaluated. Material and method: A human maxillary first premolar tooth was prepared in proper sizes for the standardization of dies on which crowns would be fractured. Impressions were taken from this tooth and dies were prepared. In the pilot study that was conducted to specify the die material, three different materials (Ni-Cr, epoxy resin, dentin) were evaluated. Feldspathic CAD/CAM ceramic crowns were prepared on the dies and fracture force was applied. Dies were prepared from epoxy resin that showed a similar fracture value to dentin. Crowns were milled from 4 different monolithic blocs (feldspathic glass ceramic 1, resin nano ceramic 2, lithium disilicate 1, and ceramic including leucite 1 type) in 3 different cement thicknesses (30, 90, 150 µm) in the CEREC 4 CAD/CAM system. For each cement thickness 7 and for one crown material 21, in total 105 samples were prepared. Crowns were cemented with a monotype self-adhesive resin cement, and after 1 hour, they were storedat 37 ° C for 1 week until the test was done. Natural teeth that were not prepared were used as the control group. A universal test machine with a cross-head speed of 1 mm/min was used to determine the fracture resistance. Force was applied on the central groove of the crowns. Results were recorded as Newton. Results: The data were evaluated with one way ANOVA and interaction modelling test with two factors (p<0.001). There was a statistically significant difference among the fracture resistance of CAD/CAM monolithic crowns (p<0.001); however, it was observed that the effect of cement thickness on the fracture resistance was not statistically significant. (p>0.001) Conclusion:The highest fracture resistance value was recorded for IPS e.max CAD (1390.327 N), and the lowest value was recorded for IPS Empres CAD (787.988 N). It was also observed that fracture resistance values were similar in cement thicknesses determined as 30, 90, and 150 µm.

Benzer Tezler

  1. Lityum disilikat kronlarda siman kalınlığı ve siman renginin restorasyonun rengine etkisi

    The effects of cement thickness and cement color on the color of lithium disilicate crowns

    ABDULLAH YİĞİT YAMALI

    Doktora

    Türkçe

    Türkçe

    2022

    Diş HekimliğiGazi Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. BİLGE TURHAN BAL

  2. CAD-CAM materyalleri ile üretilen implant üstü restorasyonların farklı siman aralıklarındaki stres dağılımlarının karşılaştırılması

    Comparison of stress distributions in different cement thicknesses of implant- retained fixed restorations produced with current CAD-CAM materials

    RAZİYE YILDIZ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. AYŞE GÖZDE TÜRK

  3. Farklı kalınlıktaki monolitik seramiklerin farklı ışık kaynakları altında rezin simanların polimerizasyon oranına etkisi

    The effect of the monolithic ceramics at different thickness under the different light sources to the resin based luting cements' degree of polymerization

    AYDAN BOZTUNA

    Doktora

    Türkçe

    Türkçe

    2017

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. İBRAHİM BÜLENT ŞERMET

  4. Farklı içerikli CAD/CAM freze lamine venerlerin iki siman aralığında kırılma dayanımlarının karşılaştırılması

    Comparison of fracture resistance of CAD/CAD laminee veners had different contents in TWO cement thicknesses

    ORHAN RIDVAN VURGEÇ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2016

    Diş HekimliğiAtatürk Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    PROF. DR. NİLGÜN SEVEN

  5. Farklı restorasyon materyallerinin iki farklı preperasyon şekli ile hazırlanmış onley restorasyonlarının adaptasyonuna ve kırılma dayanıklılığına etkisinin in vitro olarak incelenmesi

    In vitro investigation of the effect of different restoration materials on the adaptation and fracture strength of onley restorations prepared with two different techniques

    ŞÜKRÜ CAN AKMANSOY

    Doktora

    Türkçe

    Türkçe

    2023

    Diş HekimliğiMarmara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. ERKUT KAHRAMANOĞLU