Geri Dön

Değişik saklama koşullarının etanol düzeyi üzerindeki etkisinin değerlendirilmesi

Ethanol level of various storage conditionsassessment of its effect on

  1. Tez No: 834935
  2. Yazar: MELTEM BOZ
  3. Danışmanlar: DOÇ. DR. CİHAN COŞKUN
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Biyokimya, Biochemistry
  6. Anahtar Kelimeler: Etil alkol, stabilite, saklama sıcaklığı, saklama süresi, instabilite denklemi, maksimum izin verilebilir fark, şahit numune, stabilite limiti, Etanol, Kan, Kan testleri, Laboratuvarlar, Saklama, Saklama işlemleri, Teşhis testleri, Ethyl alcohol, stability, storage temperature, storage time, instability equation, maximum allowable difference, blank sample, stability limit, Ethanol, Blood, Hematologic tests, Laboratories, Retention, Storage processes, Diagnostic tests
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: Sağlık Bilimleri Üniversitesi
  10. Enstitü: İstanbul Başakşehir Çam ve Sakura Şehir Hastanesi
  11. Ana Bilim Dalı: Tıbbi Biyokimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Uzun süre saklanan etanol örnekleri birçok preanalitik değişkenden etkilenebilmektedir. Bu nedenle saklama süresi, sıcaklığı gibi etkenlerin kan etanol düzeyi üzerindeki etkisinin bilinmesi sonuç güvenilirliği bakımından önem taşımaktadır. Bu çalışmada değişik konsantrasyonlarda etanol içeren kan örneklerinin değişen sürelerde ve sıcaklıklarda saklanmasının test sonuçlarına olası etkilerini değerlendirdik. Gereç Yöntem: Çalışmamıza gönüllü katılan 400 kişiden sodyum florit katkılı tüplere kan örnekleri alındı. Tüpler santrifüj edildikten sonra bir plazma havuzu oluşturuldu. Oluşturulan havuzun etanol konsantrasyonunun <10 mg/dl olduğu doğrulandıktan sonra havuza son konsantrasyonları 50, 100, 200, 400 mg/dL olacak şekilde etil alkol eklenerek 5 farklı derişim havuzu elde edildi. Plazma havuzu her biri 7'şer porsiyon olmak üzere, 0 ile 24 saat bekletilen örnekler oda sıcaklığında, 1, 3, 6 ay süreyle bekletilen örneklerse -20 ºC ile -80 ºC'de saklanmak üzere toplam 8 alt gruba ayrıldı. Her bir grup belirtilen sürelerde ve sıcaklıklarda etanol düzeyleri ölçülmek üzere saklandı. Bulgular: 0. saat ve 24. saat oda sıcaklığında bekletilen örneklerin ortalamaları arasında (her bir konsantrasyon için) istatistiksel olarak fark bulunmadı (P>0,05). 0. saat (bazal) ile (hem -20°C'de hem -80°C'de saklanan örneklerde) 1 ay, 3 ay, 6 ay bekletilen örnek gruplarının etanol konsantrasyonlarının ortalamaları arasında istatistiksel olarak anlamlı fark bulundu (P<0,05). Etil alkol konsantrasyonlarında klinik ve analitik olarak anlamlı bir değişimin olup olmadığı etil alkol için belirlenen maksimum izin verilebilir fark (MİF) değeri kullanılarak tespit edildi. Etil alkolün MIF değerinin belirlenmesine ilişkin olarak,“Royal College of Pathologist Australasia”'nin önermiş olduğu“±%10”değeri kabul edildi. Buna göre tüm gruplardan elde edilen etil alkol sonuçlarına ait yüzde değişim (%YD) değerleri (-0,64 ile -5,47 aralığında), MİF (±%10) ile karşılaştırıldığında analitik olarak anlamlı bir farkın olmadığı bulundu. Sonuç: Özellikle adli vakalarda yasal saklama süresi boyunca muhafaza edilmesi gereken şahit numunelerin -20°C'de stabilitesi bozulmadan saklanabileceği tespit edildi. Ayrıca etanol örnekleri için“instabilite denklemi”oluşturarak her laboratuvarın ix kendi performans özelliklerine dayalı olarak, klinik gereksinimlerini karşılamak amacıyla belirlenen MİF değerlerine göre stabilite limitini hesaplamaları uygun olabilir.

Özet (Çeviri)

Aim: Ethanol samples stored for a long time can be affected by many preanalytical variables. Therefore, knowing the effect of factors such as storage time and temperature on blood ethanol level is important for the reliability of the results. In this study, we evaluated the possible effects of storing blood samples containing different concentrations of ethanol at varying times and temperatures on test results. Materials and Methods: Blood samples were taken from 400 people who voluntarily participated in our study, in tubes containing sodium fluoride. After the tubes were centrifuged, a plasma pool was created. After confirming that the ethanol concentration of the created pool was <10 mg/dl, ethyl alcohol was added to the pool with final concentrations of 50, 100, 200, 400 mg/dL to obtain 5 different concentration pools. The plasma pool was divided into a total of 8 subgroups, each with 7 portions, the samples kept for 0 to 24 hours were stored at room temperature, and the samples kept for 1, 3, 6 months were stored at -20 ºC and -80 ºC. Each group was stored for the specified periods and temperatures to measure ethanol levels. Results: There was no statistical difference (P>0.05) between the means of the samples kept at room temperature for the 0th hour and the 24th hour (for each concentration). A statistically significant difference was found between the means of ethanol concentrations at hour 0 (basal) and sample groups stored for 1 month, 3 months, 6 months (in samples stored at both -20°C and -80°C) (P<0, 05). Whether there was a clinically and analytically significant change in ethyl alcohol concentrations was determined by using the maximum allowable difference (MIF) value determined for ethyl alcohol. As for determining of the MIF value of ethyl alcohol, the value of“±10%”recommended by the“Royal College of Pathologist Australasia”was accepted. Accordingly, when the percentage change (%PD) values of ethyl alcohol results obtained from all groups (range -0.64 to -5.47) were compared with MIF (±10%), it was found that there was no analytically significant difference. Conclusion: It has been determined that witness samples, which must be kept during the legal storage period, especially in forensic cases, can be stored at -20°C without deteriorating their stability. In addition, it may be appropriate for each laboratory to xi create an“instability equation”for ethanol samples and calculate the stability limit according to the MIF values determined to meet clinical requirements, based on their own performance characteristics.

Benzer Tezler

  1. Drying and storage of immobilized microbial cells

    Başlık çevirisi yok

    NÜZHET ERTUĞAY

    Yüksek Lisans

    İngilizce

    İngilizce

    1989

    Gıda MühendisliğiOrta Doğu Teknik Üniversitesi

    DOÇ. DR. HALUK HAMAMCI

  2. Elektrodöndürme yöntemiyle elde edilen jelatin nanoliflerinin emülsiyonlarda stabilize edici olarak kullanılması

    Using electrospun gelatin nanofibers as stabilizers in emulsions

    NAGİHAN OKUTAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Gıda Mühendisliğiİstanbul Teknik Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. FİLİZ ALTAY

  3. Determination of archeal populations in anaerobic reactors using molecular techniques

    Anaerobik reaktörlerde arkeal toplulukların moleküler teknikler kullanılarak belirlenmesi

    ALPER TUNGA AKARSUBAŞI

    Doktora

    İngilizce

    İngilizce

    2003

    BiyolojiBoğaziçi Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. BAHAR KASAPGİL İNCE

    PROF. DR. BETÜL KIRDAR

  4. Çimentonun sertleşmesi üzerinde kimyasal komponentlerin etkisi

    Başlık çevirisi yok

    NACİYE TÜRKEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Kimya MühendisliğiUludağ Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA CEBE

  5. Antakya tarihi ticaret merkezi mekansal yapı değişim ve gelişim sürecinin kent ticaret merkezi planlamasına etkinliği

    The Effectiveness of spatial structural chance and development period of the historical trade center of Antakya in the urban trade planning

    NEVİN TURGUT

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Şehircilik ve Bölge PlanlamaGazi Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    YRD. DOÇ. DR. NURCAN UYDAŞ