Asetabulum anterior kolon kırıklarında perkutan retrograd kolon vidası planlanan hastalarda kullanılan vida boyu ve vida kalınlığının üç boyutlu BT yardımı ile preoperatif belirlenmesi
Preoperative determination of screw length and screw thickness with three-dimensional CT assistance in patients which are planning percutan retrograd column screw in acetabulum anterior column fractures
- Tez No: 829197
- Danışmanlar: DR. ÖĞR. ÜYESİ FATİH DURGUT
- Tez Türü: Tıpta Uzmanlık
- Konular: Ortopedi ve Travmatoloji, Orthopedics and Traumatology
- Anahtar Kelimeler: Asetabulum, anterior kolon, ramus pubis superior, retrograd, sagital açı, koronal açı, perkutan, fiksasyon, minimal invaziv, Kemik vidaları, Kırık fiksasyonu, Kırıklar-kemik, Ortopedi, Ortopedik aygıtlar, Acetabulum, anterior column, ramus pubis superior, retrograde, sagittal angle, coronal angle, percutaneous, fixation, minimally invasive, Bone screws, Fracture fixation, Fractures-bone, Orthopedics, Orthopedic equipment
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Dicle Üniversitesi
- Enstitü: Tıp Fakültesi
- Ana Bilim Dalı: Ortopedi ve Travmatoloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç:Bu çalışmamızda asetabulum anterior kolon kırıklarında perkutan retrograd fiksasyon için uygun hastalarda yerleştirilecek vidaların boy ve kalınlıklarını üç boyutlu bilgisayarlı tomografiler ile ölçmek, bu ölçümlerin cinsiyetler arasındaki farklılığını ortaya koymak amaçlandı. Ayrıca anterior kolon ramus pubik superior arasındaki açının vida kalınlığı üzerine etkisini değerlendirme amaçlandı. Gereç ve yöntem: 2016–2021 tarihleri arasında Dicle Üniversitesi tıp fakültesi Hastanesi'nde pelvis bilgisayarlı tomografisi çekilen 384 pelvik patolojisi olmayan hasta geriye dönük (retrospektif) olarak incelendi. Radyolojik verileri uygun görülen 384 hasta çalışmaya dahil edildi. Hastaların radyolojik değerlendirmesi yapılıp ramus pubik superior ve anterior kolonda uygun seviyede kesiler yapıldı. Bu kesilerden vida boyu, vida kalınlığı ölçüldü. Asetabulum anterior kolon ramus pubis superior birleşim yerindeki açılar ölçüldü. Vida gönderilme esnasında vida aksının sagital ve koronal düzlem ile yaptığı açıları ölçüldü. Bulgular: Çalışmamızda 384 hemipelvis incelendi.Çalışmaya dahil edilen hastaların 174(%45.3)'u kadın, 210(%54.7)'u erkektir. Yaş ortalaması 48.18. Kadınlarda yaş ortalaması 46.4, erkeklerde yaş ortalaması ise 49.5'ti. Kullanılacak vida çapı erkeklerde ortalama 4.38mm, kadınlarda 4 mm ölçüldü. Vida uzunluğu erkeklerde 116,5 kadınlarda 103.6 olarak bulduk.Yerleştirilecek vidanın koronal düzlem ile yaptığı açı 61 derece sagital düzlemle yaptığı açı ise 31 derece olarak değerlendirildi.Asetabulum anterior kolon ile ramus pubis superior arsasındaki açı erkeklerde ve kadınlarda benzer olup 157 olarak ölçüldü.Vida çapının erkek ve kadınlar arsındaki farklar istatistiksel olarak anlamlıydı(p<0.05). Asetabulum anterior kolon ile ramus pubis superior arsasındaki açı ile vida çapı arasında anlamlı ilişki mevcuttur. Ancak bu açı erkek ve kadınlar arasında istatistiksel olarak farklılık göstermemektedir. Sonuçlar:Yerleştirilecek vida çapı değerlendirilirken erkek ve kadın cinsiyet arasındaki fark gözetilmelidir. Ayrıca yerleştirilecek vida çapı, asetabulum anterior kolon ile ramus pubis superior birleşim yerindeki açı artıkça artmaktadır. yerleştirilecek vidanın koronal ve sagital düzlem ile yaptığı açı preoperatif çekilen bilgisayarlı tomografi ile belirlenmelidir.
Özet (Çeviri)
Aim: In this study, measuring the length and thickness of the screws for percutaneous retrograde fixation in acetabulum anterior column fractures with three-dimensional computed tomography,It was aimed to reveal the difference of these measurements between the genders.In addition, it was aimed to evaluate the effect of the angle between the anterior column and ramus pubic superior on the screw thickness. Material and Method:A retrospective study of 384 patients without pelvic pathology, who underwent pelvic computed tomography at Dicle University Hospital between 2016–2021, was retrospectively analyzed.384 patients with appropriate radiological data were included in the study.After radiological evaluation of the patients, appropriate level incisions were made in the ramus pubic superior and anterior column.. Screw length and screw thickness were measured from these incisions.Angles between the acetabulum anterior column and ramus pubis superior were measured.We measured the angles of the screw axis with the sagittal and coronal planes during screw delivery. Results:In our study, 384 hemipelvis were examined.Of the patients included in the study, 174 (45.3%) were female and 210 (54.7%) were male.The average age is 48.18. The mean age for women was 46.4, and the mean age for men was 49.5.The screw diameter to be used was measured as 4.38mm in men and 4mm in women.We found the screw length to be 116.5 for males and 103.6 for females.The angle of the screw to be sent with the coronal plane was 61 degrees, and the angle with the sagittal plane was 31 degrees.The angle between the anterior column of the acetabulum and the superior ramus pubis was similar in men and women and was measured as 157.The differences in screw diameter between men and women were statistically significant (p<0.05).There is a significant relationship between the angle of the acetabulum anterior column and the ramus pubis superior plot and the screw diameter.However, this angle does not differ statistically between men and women. Conclusion:When evaluating the screw diameter to be sent, the difference between male and female gender should be considered.In addition, the diameter of the screw to be sent increases as the angle between the anterior column of the acetabulum and the superior ramus pubis increases.The angle of the screw to be sent with the coronal and sagittal plane should be determined by preoperative computed tomography.
Benzer Tezler
- Modifiye ucu eğilmiş tel tekniği ile perkütan vida uygulanan asetabulum anterior kolon kırıklarının klinik sonuçları
Clinical outcomes of anterior column fractures treated with percutaneous screws using the modified bent wire technique
FIRAT AL
Tıpta Uzmanlık
Türkçe
2025
Ortopedi ve Travmatolojiİnönü ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
DOÇ. DR. OKAN ASLANTÜRK
- Cerrahi tedavi yapılan pelvis ve asetabulum kırıklarında kan yönetimi
Blood management in surgically treated pelvis and acetabulum fractures
EMRE SÖNMEZ
Tıpta Uzmanlık
Türkçe
2023
Ortopedi ve TravmatolojiSağlık Bilimleri ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
DOÇ. DR. ÖZHAN PAZARCI
- Anterior kolon – posterior hemitransvers tip asetabulum kırıklarında modifiye stoppa yaklaşımı kullanılarak uygulanan farklı fiksasyonların biyomekanik özelliklerinin araştırılması
Different fixation techniques for anterior column posterior hemitransverse type acetabular fractures by using modified stoppa approach – A biomechanical experiment
OĞUZHAN TANOĞLU
Tıpta Uzmanlık
Türkçe
2017
Ortopedi ve TravmatolojiSağlık Bilimleri ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF. DR. KADİR BAHADIR ALEMDAROĞLU
- Anterior kolon kırıklarında suprapektineal plağın pelvik brime uzaklığı stabiliteyi etkiliyor mu? Biyomekanik çalışma
Does the pelvic brime distance of the suprapectineal plate affect stability in anterior column fractures? Biomechanical study
MEHMET BURAK GÖKGÖZ
Tıpta Uzmanlık
Türkçe
2019
Ortopedi ve TravmatolojiSağlık Bilimleri ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF. DR. KADİR BAHADIR ALEMDAROĞLU
- Finite element modelinde asetabulum anterior kolon kırığının kilitli, kilitsiz ve kombine plaklar ile intrapelvik veya suprapubik fiksasyonunun stabilite ve gerinim açısından karşılaştırılması
Comparison of stability and tension against the locked, unlocked and combined plates and intrapelvic or suprapubic fixation of the acetabulum anterior column fracture in the finite element model
MEHMET YÜCENS
Tıpta Uzmanlık
Türkçe
2014
Ortopedi ve TravmatolojiSağlık BakanlığıOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF. DR. KADİR BAHADIR ALEMDAROĞLU