Nükleer tıpta PET/CT (pozitron emisyon tomografisi/ bilgisayarlı tomografi) ve sintigrafi uygulamalarında çalışan hemşirelerin radyoaktif maddelerle çalışırken maruz kaldığı radyasyon dozlarının karşılaştırılması
Comparison of radiation doses exposed when working with radioactive substances of nurses working in nuclear medicine PET/CT (Positron emission tomography/ computerized tomography) and scitigraphy applications
- Tez No: 791241
- Danışmanlar: PROF. DR. NİLÜFER YILDIRIM
- Tez Türü: Yüksek Lisans
- Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
- Anahtar Kelimeler: dozimetre, nükleer tıp, radyasyondan korunma, radyasyon doz maruziyeti, Doz-cevap ilişkisi-radyasyon, Pozitron emisyon tomografi, Radyasyon dozajı, Radyasyon etkileri, Radyometri, dosimeter, nuclear medicine, radiation dose exposure, radiation protection, Dose-response relationship-radiation, Positron-emission tomography, Radiation dosage, Radiation effects, Radiation-protection, Radiometry
- Yıl: 2023
- Dil: Türkçe
- Üniversite: Ankara Yıldırım Beyazıt Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Radyoloji Ana Bilim Dalı
- Bilim Dalı: Sağlık Fiziği Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Nükleer tıpta kullanılan radyoaktif maddeler çalışan personellerin radyasyon dozuna maruz kalmasına sebep olmaktadır. Nükleer tıpta görev yapan hemşireler radyoaktif maddeleri hastalara çoğu zaman damar yolu ile vermektedir. Bu sebeple hemşireler radyasyon dozuna direk olarak maruz kalmaktadırlar. Sintigrafi ve PET/CT çekimleri için farklı yarı ömür ve enerjiye sahip radyofarmasötikler kullanılmaktadır. Sintigrafi çekimleri için yarı ömrü 6 saat olan ve 140 keV enerjiye sahip Tc-99m olduğu bilinmektedir. PET/CT çekimleri ise yaklaşık 110 dk yarı ömre sahip F-18 ile yapılmaktadır. PET/CT cihazının pozitron yaydığı bilinirken, bu pozitronların enerjisi 511 keV olduğu bilinmektedir. Bu sebeple görev yapan personeller PET/CT uygulamaları sırasında yüksek radyasyon dozuna maruz kalacağını düşünmektedirler. Buna karşılık F-18 radyonüklidin kısa yarı ömre sahip olmasından kaynaklı hasta sayıları sintigrafi uygulamalarına göre daha az olmaktadır. Başka bir deyişle, sintigrafi uygulamalarında görev yapan hemşire daha fazla hastaya radyoaktif madde vermektedir. Bu durum da gerçekte 'Pet/ct uygulamaları için hastalara F-18 maddesi enjekte eden hemşirelerin sintigrafi uygulamaları için Tc-99m enjekte eden hemşirelere göre daha fazla radyasyon dozu alır mı?' sorusuna cevap aramamıza imkân sağlamıştır. Araştırmamızda Ankara Şehir Hastanesi Nükleer Tıp Anabilim dalındaki PET/CT kısmında çalışan iki hemşire ve sintigrafi uygulamalarında çalışan iki hemşireye ait yaka ve yüzük dozimetre sonuçları karşılaştırılmıştır. Dört hemşirenin de 2019 yılından başlayarak 2022 yılının birinci periyod dönemine kadar toplam 19 periyod dönemine ait yaka ve yüzük dozimetre sonuçları istatistiksel olarak incelenmiştir. Yaka ve yüzük dozimetre sonuçları hem PET/CT uygulamaları yapan hemşireler hem de sintigrafi uygulamaları yapan hemşireler için elimizde ayrı ayrı 78 adet olmak üzere toplam 156 adet veri elde edildi. Elde edilen bu veriler SPSS istatistiksel programı kullanılarak incelendi ve dozimetre sonuçları arasında istatistiksel olarak anlamlı fark olduğu tespit edildi. Bu farka göre görülmüştür ki, hasta sayıları az olsa da PET/CT uygulamaları sırasında görev yapan hemşirelerin radyasyon dozu maruziyeti gerçekte de fazladır.
Özet (Çeviri)
Radioactive materials used in nuclear medicine cause the personnel to be exposed to radiation dose. Nurses working in nuclear medicine often give radioactive materials to patients intravenously. For this reason, nurses are directly exposed to the radiation dose. Radiopharmaceuticals with different half-lives and energies are used for scintigraphy and PET/CT imaging. It is known that Tc-99m has a half-life of 6 hours and an energy of 140 keV for scintigraphy shots. PET/CT scans are made with F-18, which has a half-life of approximately 110 minutes. While it is known that the PET/CT device emits positrons, the energy of these positrons is known to be 511 keV. For this reason, the personnel on duty think that they will be exposed to high radiation dose during PET/CT applications. On the other hand, due to the short half-life of the F-18 radionuclide, the number of patients is less than in scintigraphy applications. In other words, nurses working in scintigraphy applications give radioactive substances to more patients. This situation has enabled us to seek an answer to the question,“Do nurses who inject F-18 substance to patients for Pet/CT applications receive more radiation dose than nurses who inject Tc-99m for scintigraphy applications?”. In our study, collar and ring dosimetry results of two nurses working in the PET/CT department of Ankara City Hospital Nuclear Medicine Department and two nurses working in scintigraphy applications were compared. The collar and ring dosimetry results of four nurses for a total of 19 periods, starting from 2019 to the first period of 2022, were statistically analyzed. Collar and ring dosimetry results were obtained for both nurses performing PET/CT applications and nurses performing scintigraphy applications, a total of 156 data, 78 of which were separately available. These obtained data were analyzed using the SPSS statistical program and it was determined that there was a statistically significant difference between the dosimetry results. According to this difference, it has been seen that although the number of patients is low, the radiation dose exposure of the nurses working during PET/CT applications is actually high.
Benzer Tezler
- Synthesis of folate receptor 1 targeted dye-conjugated peptides for use in positron emission tomography imaging systems
Pozitron emisyon tomografi görüntüleme sistemlerinde kullanılacak folate receptör 1 hedefli boya takılı peptitlerin sentezi
DERYA CİN
Yüksek Lisans
İngilizce
2022
Bilim ve Teknolojiİstanbul Teknik ÜniversitesiNanobilim ve Nanomühendislik Ana Bilim Dalı
DR. ÖĞR. ÜYESİ ONUR ALPTÜRK
DR. ÖZGÜR YILMAZ
- Effective dose estimation with IDAC and OLINDA programs for oncological PET/CT procedures
Onkolojik PET/BT taramalarında IDAC ve OLINDA programları ile etkin doz değerlendirmesi
FATMA HİLAL BİKİRLİ
Yüksek Lisans
İngilizce
2024
Radyoloji ve Nükleer Tıpİstanbul Teknik ÜniversitesiNükleer Araştırmalar Ana Bilim Dalı
PROF. DR. NESRİN ALTINSOY
- Kanserli olguların metastaz taramasında tüm vücut manyetik rezonans görüntülemenin önemi
Metastases screening with whole-body magnetic resonance imaging in patient with known malignant tumors
KADER ŞEBNEM BAĞCIER
Tıpta Uzmanlık
Türkçe
2006
Radyoloji ve Nükleer TıpKırıkkale ÜniversitesiRadyoloji Ana Bilim Dalı
DOÇ.DR. SİMAY KARA
- Non-Hodgkin lenfomada FDG PET/BT görüntülemenin hasta evrelemesinde, tedaviye yanıtın değerlendirilmesinde ve yeniden evrelemede rolü
The role of FDG PET/CT scan in staging, evaluation of treatment response and restaging in patients with non-Hodgkin?s lymphoma
GÜLİZ DURAK
Tıpta Uzmanlık
Türkçe
2009
Radyoloji ve Nükleer TıpGaziantep ÜniversitesiNükleer Tıp Ana Bilim Dalı
DOÇ. DR. MUSTAFA YILMAZ
- Plevral kitlelerin benign/malign yönünden ayirici tanisinda FDG PET-BT görüntülemenin rolü
The role of FDG PET-CT imaging in differantial diagnosis of malignant and benign pleural masses evaluation
UMUT ELBOĞA
Tıpta Uzmanlık
Türkçe
2009
Radyoloji ve Nükleer TıpGaziantep ÜniversitesiNükleer Tıp Ana Bilim Dalı
DOÇ. DR. MUSTAFA YILMAZ