İntrapartum fetal distres olgularında yenidoğan kord kanında fetal asfiksi göstergesi olarak nükleuslu kırmızı kan hücreleri
Nucleated red blood cells as an indicator of fetal asphyxia in neonatal cord blood in cases of intrapartum fetal distress
- Tez No: 785347
- Danışmanlar: DOÇ. DR. ORHAN GELİŞEN, PROF. DR. FARUK SUAT DEDE
- Tez Türü: Tıpta Uzmanlık
- Konular: Kadın Hastalıkları ve Doğum, Obstetrics and Gynecology
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2004
- Dil: Türkçe
- Üniversite: Sağlık Bakanlığı
- Enstitü: Ankara Etlik Zübeyde Hanım Kadın Hastalıkları Eğitim ve Araştırma Hastanesi
- Ana Bilim Dalı: Kadın Hastalıkları ve Doğum Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Perinatal asfiksinin göstergesi olduğu kanıtlanmış umblikal kord kanında nükleuslu kırmızı kan hücrelerinin (NRBC) sayısının, asfiksi tanısı olmaksızın term ve ek obstetrik problemi olmayan yenidoğanlarda, fakat intrapartum fetal kalp hızı trasesi anormallikleri ve mekonyum varlığı ile ilişkisini değerlendirmek. Materyal ve metod: 41 term, doğum eylemi sırasında geç veya ciddi değişken deselerasyonları olan veya mekonyumlu amniotik sıvısı bulunan gebeliklerden oluşan fetal distres (FD) grubu ile 45 term gebeden oluşan kontrol grubu karşılaştırıldı. Preterm eylem, Rh-Rh uygunsuzluğu, fetal anemi, diabetik anne, intrauterin gelişme geriliği, preeklampsi ve çoğul gebelik gibi durumlar çalışma kapsamı dışında bırakıldı. Olgular doğum travayı süresince aralıklı fetal kalp atımı dinlenmesi veya eksternal elektronik fetal kalp monitorizasyonu ile takip edildi. Doğumu takiben her hastadan umblikal kord kanından kan gazı ve NRBC için örnek alındı. Yenidoğanların 1. ve 5. dakika APGAR skorları kaydedildi, boy ve ağırlık ölçümleri alındı. Doğum şekli kaydedildi. Tüm bebekler, yenidoğan yoğun bakım ünitesine kabul gerekliliği açısından takip edildi. Her iki grup SPSS for Windows 10.0 programı kullanılarak Mann-Whitney U, student t test, Pearson ve Spearman korelasyon katsayıları kullanılarak karşılaştırıldı. Bulgular:FD grubunda her 100 beyaz küreye karşılık nükleuslu kırmızı kan hücresi sayısı ortalama 6,76+5,14, kontrol grubunda ise ortalama 4,51+3,79 bulunmuştur ve aradaki fark istatistiksel olarak anlamlıdır (p<0.05). Ayrıca nükleuslu kırmızı kan hücresi sayısı ile amnion sıvısında mekonyum varlığı (p<0.05) arasında korelasyon mevcuttur. Sonuç: Sunulan çalışmada NRBC, FD grubunda belirgin yüksek bulunmuştur. Fetal hipoksinin bir göstergesi olarak bu yöntem noninvaziv ve oldukça kolaydır. Fetal hipoksinin uzun dönem sonuçlarının tespitinde bu yöntemin belirleyiciliği için daha fazla çalışmaya ihtiyaç vardır.
Özet (Çeviri)
Purpose: To evaluate the relationship between the number of nucleated red blood cells (NRBC) in the umbilical cord blood, which has proven to be an indicator of perinatal asphyxia, in term newborns without a diagnosis of asphyxia and without additional obstetric problems, but with intrapartum fetal heart rate tracing abnormalities and the presence of meconium. Material and method: The FD group consisting of 41 term, late or severe variable decelerations during labor or those with meconium amniotic fluid was compared with the control group consisting of 45 term pregnants. Conditions such as preterm labor, Rh-Rh incompatibility, fetal anemia, diabetic mother, intrauterine growth retardation, preeclampsia and multiple pregnancy were excluded from the study. The cases were followed up with intermittent fetal heartbeat listening or external electronic fetal heart monitoring during labor. After delivery, samples were taken from umbilical cord blood for blood gas and NRBC from each patient. First and fifth minute APGAR scores of newborns were recorded, height and weight measurements were taken. The mode of birth was recorded. All infants were followed up for the necessity of admission to the neonatal intensive care unit. Both groups were compared using the SPSS for Windows 10.0 program using Mann-Whitney U, student t test, Pearson and Spearman correlation coefficients. Results: The mean NRBC count per 100 white blood cells in the FD group was 6.76+5.14, and the mean was 4.51+3.79 in the control group, and the difference was statistically significant (p<0.05). In addition, there is a correlation between the number of NRBC and the presence of meconium in the amniotic fluid (p<0.05). Conclusion: In the present study, NRBC were found to be significantly higher in the FD group. As an indicator of fetal hypoxia, this method is noninvasive and fairly easy. More studies are needed to determine the long-term results of fetal hypoxia to determine this method.
Benzer Tezler
- Term gebelerde intrapartum fetal zayıflığın öngörüsünde serebroplasental oranın yeri
The importance of cerebroplacental ratio in predicting intrapartum fetal compromise at term
BURCU UÇAR
Tıpta Uzmanlık
Türkçe
2020
Kadın Hastalıkları ve DoğumEge ÜniversitesiKadın Hastalıkları ve Doğum Ana Bilim Dalı
PROF. DR. M. SAİT YÜCEBİLGİN
- Düşük riskli term tekil gebeliklerde intrapartum fetal kardiyotokografi değerlendirmesinin neonatal kötü obstetrik sonuçlarla ilişkisinin prospektif araştırılması
A prospective investigation of the association between intrapartum fetal cardiotocography evaluation and adverse neonatal outcomes in low-risk term singleton pregnancies
CANSU DAĞ
Tıpta Uzmanlık
Türkçe
2025
Kadın Hastalıkları ve DoğumSağlık Bilimleri ÜniversitesiKadın Hastalıkları ve Doğum Ana Bilim Dalı
DOÇ. DR. NERGİZ KENDER ERTÜRK
- Kategori II FHR trasesine sahip fetüslerin erken neonatal sonuçlarının incelenmesi
Investigation of early neonatal results of fetuses with category II FHR trace
FATMA BETÜL ŞAHİN
Tıpta Uzmanlık
Türkçe
2022
Kadın Hastalıkları ve DoğumSağlık Bilimleri ÜniversitesiKadın Hastalıkları ve Doğum Ana Bilim Dalı
PROF. DR. HÜSEYİN LEVENT KESKİN
- Gebelik ve hipertansiyon olgularında feto-maternal doppler analizlerinin perinatal morbidite ve mortaliteyi saptamadaki rolü
Başlık çevirisi yok
TANJU DEMİRÖREN
Tıpta Uzmanlık
Türkçe
1994
Kadın Hastalıkları ve Doğumİstanbul ÜniversitesiKadın Hastalıkları ve Doğum Ana Bilim Dalı
- Elektronik fetal kalp hızı monitörizasyonu: Normal monitör, fetal stres, fetal distres ile ilişkili erken neonatal sonuçlar
Başlık çevirisi yok
NADİR COMART
Tıpta Uzmanlık
Türkçe
2006
Çocuk Sağlığı ve HastalıklarıSağlık BakanlığıÇocuk Sağlığı ve Hastalıkları Ana Bilim Dalı
DR. H.CEMAL ARK