Absorbsiyonlu soğutma yapılan bir mini buzdolabının hesaplamalı akışkan dinamiği destekli ekserji analizi
Computational fluid dynamics assisted exergy analysis of a mini refrigerator with absorption cooling
- Tez No: 779752
- Danışmanlar: DR. ÖĞR. ÜYESİ ANIL BAŞARAN
- Tez Türü: Yüksek Lisans
- Konular: Makine Mühendisliği, Mechanical Engineering
- Anahtar Kelimeler: Ekserji, Enerji verimliliği, Hesaplamalı akışkanlar dinamiği (HAD), Soğutma sistemleri, Exergy, Energy efficiency, Computational fluid dynamics (HAD), Cooling systems
- Yıl: 2023
- Dil: Türkçe
- Üniversite: Manisa Celal Bayar Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Termodinamik Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Enerjinin öneminin giderek arttığı bu günlerde, soğutma sistemlerinin performanslarının geliştirilmesi büyük önem arz etmektedir. 2021 yılı itibari ile Avrupa Birliği (AB) tarafından yayımlanan yeni enerji regülasyonu kapsamında, üretici firmaları enerji verimlilikleri bakımından iyileştirme yapmaya teşvik etmektedir. Absorbsiyonlu soğutma sistemlerin enerji tüketim değerleri çok iyi olmamasına rağmen kompresörlü ürünlere göre sessiz çalışmaları ve çevre dostu akışkanlar kullanılması sebebi ile özellikle turizm sektöründe öncelikli soğutma sistemlerinden biri olarak görülmektedir. Bu kapsamda, tek kademeli difüzyonlu absorbsiyonlu minibar buzdolabının termodinamik analizi gerçekleştirilmiştir. Ele alınan minibar buzdolabında soğutucu akışkan olarak amonyak, soğurucu akışkan olarak su, basınç dengeleyici olarak helyum gazı ve güç kaynağı olarak elektrikli rezistans kullanılmıştır. Çalışmada termodinamik analiz için minibar buzdolabı bir deney düzeneği olarak düzenlenmiş ve minibar buzdolabının farklı noktalarından sıcaklık ve basınç ölçümleri gerçekleştirilmiştir. Deneysel ölçümler hem minibar soğutma kabininde hem de absorbsiyonlu soğutma çevriminde gerçekleştirilmiştir. Ele alınan minibarın ekserji analizi Hesaplamalı Akışkanlar Dinamiği (HAD) analizi ile desteklenmiştir. Deneysel ölçümlerle gerçekleştirilen enerji ve ekserji analizine ek olarak HAD analizi ile soğutulan kabinin entropi üretimi hesaplanmıştır. Bu tez çalışmasında uygulanan HAD yöntemleri sıcaklık ölçümleri ile doğrulanmıştır. Soğutulan kabinin deneysel sıcaklık ölçümleri ile HAD simülasyon sıcaklıkları arasındaki ortalama mutlak hata yüzdesi (MAE) %3,4 olarak bulunmuştur. Analiz sonucuna göre en yüksek ısı transfer hızının 27,2 W ile ayırıcıda meydana geldiği tespit edilmiştir. Bu tez çalışmasında absorbe minibardaki en yüksek ekserji yıkımı 9,02 W ile ısı değiştiricide olduğu sonucuna varılmıştır. Absorbe minibarın ekserji verimliliği 0,719; Etkinlik Tesir Katsayısı (COP) 0,13 olarak bulunmuştur.
Özet (Çeviri)
In these days when the importance of energy is increasing, it is of great importance to improve the performance of cooling systems. As of 2021, within the scope of the new energy regulation published by the European Union (EU), manufacturers are encouraged to make improvements in terms of energy efficiency. Although the energy consumption values of absorption cooling systems are not very good, they are seen as one of the priority cooling systems, especially in the tourism sector, due to their quiet operation and the use of environmentally friendly fluids compared to compressor products. In this context, thermodynamic analysis of a single-stage diffusion-absorption minibar refrigerator was carried out. Ammonia was used as the refrigerant fluid, water as the absorbent fluid, helium gas as the pressure balancer and electrical resistance as the power source in the minibar refrigerator considered. In the study, the minibar refrigerator was arranged as an experimental setup for thermodynamic analysis and temperature and pressure measurements were made from different points of the minibar refrigerator. Experimental measurements were carried out both in the minibar cooling cabinet and in the absorption cooling cycle. The exergy analysis of the considered minibar was supported by the Computational Fluid Dynamics (CFD) analysis. In addition to the energy and exergy analysis performed with experimental measurements, the entropy production of the cooled cabin was calculated by CFD analysis. CFD methods applied in this thesis study were verified by temperature measurements. The mean absolute percent error (MAE) between the experimental temperature measurements of the cooled cabinet and the CFD simulation temperatures was found to be 3.4%. According to the results of the analysis, it was determined that the highest heat transfer rate occurred in the separator with 27.2 W. In this thesis study, it was concluded that the highest exergy destruction in the absorbed minibar was in the heat exchanger with 9.02 W. The exergy efficiency of the absorb minibar is 0.719; The Efficiency Effect Coefficient (COP) was found to be 0.13.
Benzer Tezler
- Purification of bacteriorhodopsin from halobacterium halobium and reconstitution studies in liposomes
Başlık çevirisi yok
M.BAKER ZABUT
Yüksek Lisans
İngilizce
1987
BiyokimyaOrta Doğu Teknik ÜniversitesiBiyokimya Ana Bilim Dalı
YRD. DOÇ. DR. MERAL YÜCEL
- ŞAl2 Cr (HC00)3 (OH)3 Cl3Ö kompleksinin yapısı ve tabakalama“Tanning”kapasitesinin araştırılması
Başlık çevirisi yok
AYSUN AÇU
- Laktat dehidrogenaz tayini için klinik kullanıma uygun yöntem araştırması
The investigation of a suitable method for the determination of lactate dehidrogenase in routine analysis
SEVTAP BAKIR ÇETİNTARAKÇI
Yüksek Lisans
Türkçe
1984
BiyokimyaCumhuriyet ÜniversitesiBiyokimya Ana Bilim Dalı
YRD. DOÇ. DR. AHMET AKER
- Patates çeşitlerinin dondurulmasında ön işleme teknikleri ve kaliteye etkileri
Başlık çevirisi yok
Y.BİROL SAYGI
Yüksek Lisans
Türkçe
1984
Gıda MühendisliğiEge ÜniversitesiGıda Teknolojisi Ana Bilim Dalı
YRD. DOÇ. DR. SUZAN KINCAL
- Effect of metal surface coating on the moisture absorption characteristics of cfrp
Başlık çevirisi yok
SELMA ŞİMŞEK