Effects of surgical misalignment of total ankle arthroplasty with anatomical surface morphology on ankle mechanics through a three-dimensional image based dynamic model of the ankle.
3 boyutlu dinamik modelleme yoluyla ayak bileği cerrahi onarımında yanlış takilmis implant'in anatomik, yüzeysel ve morfolojik etkilerinin arastirilmasi
- Tez No: 775592
- Danışmanlar: PROF. DR. SORIN SİEGLER
- Tez Türü: Yüksek Lisans
- Konular: Makine Mühendisliği, Mechanical Engineering
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2018
- Dil: İngilizce
- Üniversite: Drexel Unıversıty
- Enstitü: Yurtdışı Enstitü
- Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Makine Mühendisliği Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Ayak bileği implantı ameliyatlarının (ABI) ana hatalardan birisi yanlış pozisyon veya düzgün takip edilmemiş prosedür sonucu yanlış yerleştirilmiş implantlardır. Bu yanlis yerleştirilmiş implant lokal basinclara ve dolayisiyla bozulmalara sebep olmaktadir. Bu calismada 3 boyutlu resim bazli modelleme ayak bileği hareketlerini simüle etmek icin kullanilmistir. Yanlis takilmis implantin etkilerini incelemek icin onceki gelişmeler ve onaylanmis calismalar sonucunda geliştirilmiş bir model kullanilmistir, Kaval ve asik kemiğinin doğal yüzeleri kemiklerin yüzeylerini gibi davranan SSCL implanti ile değiştirilmiştir. Gerrahi prosedüre göre mükemmel implant değişimi icin, implantlar birbirlerine tam bir şekilde paralel olmalidir ve tam birleşme olmalidir. Bu calismada yanlis pozisyonlar 2 mm yukari-asagi 3 mm disariya-içeriye yer değiştirme, 10 derece donme acisi ile içeri-disari ve one-arkaya olmak üzere kaval kemiği baz alinarak seçilmiştir. Simülasyonlar ADAMS programi kullanilarak oluşturulmuştur. Yer değiştirme, hareket araligi, bukulmezligi, ligamentler üzerine düşen kuvvet ve gerilimler ve kinematik birliktelik hareketin gerçek hayattaki haraket kuvvetler simule edilen bileğin üzerine uygulanarak elde edilmiştir. Hatali implant değişimi ayak bileğinin hareketlerini önemli ölçüde etkilemekte ve bükülme zorluklari ve yüzey yüzey deformasyonuna neden olmaktadir. Bu hata ligament üzerine gelen kuvvet ve gerilimleri de degistirmektedir. Bu calismadaki hatali ayak bileği implantinin etkileri ilerideki kritik hatalari çözmek ve daha verimli bir implant değişimi yapmak icin bir tahmin araci olarak kullanılabilir.
Özet (Çeviri)
One of the main reason of the failure of total ankle replacement (TAR) is misaligned implants which mean inserting implants to a wrong position, which is not determined in a surgical procedure, in the bone. The misalignment leads to increase and localize contact pressure leading to the failure of TAR. 3D-Muscuskaleton image-based model was used to simulate the ankle and ankle motion characteristic. Previously developed and validated study of ankle joint complex was adopted to investigate the effect of TAR misalignment on the ankle joint complex. The neutral surface of tibia and talus surface was replaced with the SSCL design implant to mimicking the boundary of the bones surface. For optimally aligned implants according to the surgical procedure should be parallel to each other and have full contact between contact surface. A misalignment was composed by translating, which is 2 mm upward, 2 mm downward, 3 mm anterior, 3 mm posterior, and rotating, which is 10-degree inversion-eversion, and 10-degree internal-external, tibial part of the implant. Simulations were run by ADAMSTM. The results, which are distance mapping, the range of motion (ROM), stiffness, ligament force and strain, and kinematic coupling, were derived by using the applied loads, the displacement, which was produced by motion, and the forces in ligaments. Misalignment of TAR has a significant influence on the ankle joint complex especially stiffness of the ankle and surface to surface interaction. It changes forces and strains of the surrounded ligaments, as well. Knowledge of the effects of misalignment of TAR can be used as a predictive tool to estimate the most critical misalignment type and to solve critical issues.
Benzer Tezler
- Total diz artroplastisinde komponent yerleşim hataları
Component placement failures in total knee arthroplasty
ÖZHAN ŞAKI
Tıpta Uzmanlık
Türkçe
2014
Ortopedi ve TravmatolojiAdnan Menderes ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF. DR. İLHAN ÖZKAN
- Eklem içi uzanım göstermeyen distal femur kırıklarında lateral kilitli plak ile retrograd intramedüller çivinin klinik ve radyolojik sonuçlarının karşılaştırılması
Comparison of clinical and radiological outcomes of lateral locking plate and retrograde intramedullary nail in extra-articular distal femur fractures
ADİL ALİ ÖZİHTİYAR
Tıpta Uzmanlık
Türkçe
2026
Ortopedi ve TravmatolojiSağlık BakanlığıOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF. DR. UYGAR DAŞAR
- Posterior tibial eğim ve patellar tendon oryantasyon ilişkisinin ön çapraz bağ rüptürü üzerine etkisi
The effect of the relationship of posterior tibialslope and patellar tendon orientation on ancientcross-ligate ruptureposterior tibial eğim
MEHMET DEMİRYÜREK
Tıpta Uzmanlık
Türkçe
2023
Ortopedi ve TravmatolojiNecmettin Erbakan ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF. DR. ONUR BİLGE
- Medial açık kama proksimal tibial osteotomi hastalarında düzeltme açısının osteotomi dolma oranına etkisinin bilgisayarlı tomografi ile değerlendirilmesi ve erken dönem klinik sonuçlarla ilişkisi
Evaluation of the effect of correction angle on osteotomy filling rate in medial open wedge proximal tibial osteotomy patients with computed tomography and its relationship with early clinical outcomes
MUHAMMET YILDIRIM
Tıpta Uzmanlık
Türkçe
2025
Ortopedi ve TravmatolojiGazi ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF. DR. HAKAN YUSUF SELEK