EMG filter design for high power high frequency sups
Yüksek güç ve yüksek frekanslı anahtarlamalı güç kaynağı için EMG filtresi tasarımı
- Tez No: 75769
- Danışmanlar: DR. IŞIK ÇADIRCI
- Tez Türü: Yüksek Lisans
- Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
- Anahtar Kelimeler: EMG (Elektromanyetik Girişim), Yüksek Güçlü AGK, OM (Ortak Mod) Girişim, FM (Farksal Mod) Girişim. iv, Elektromiyografi, Filtreler, Güç kaynakları, EMI (Electromagnetic Interference) Filter, High Power SMPS, CM (Common Mode) Interference, DM (Differential Mode) Interference. in, Electromyography, Filters, Power sources
- Yıl: 1998
- Dil: İngilizce
- Üniversite: Orta Doğu Teknik Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
öz YÜKSEK GÜÇ VE YÜKSEK FREKANSLI ANAHTARLAMALI GÜÇ KAYNAĞI İÇİN EMG FİLTRESİ TASARIMI ERİŞTİREN Yalım Yüksek Lisans, Elektrik ve Elektronik Mühendisliği Bölümü Tez Yöneticisi: Dr. Işık ÇADIRCI Haziran 1998, 134 sayfe Bu çalışmada, anahtarlama frekansı 20 KHz ve çıkış gücü 4 KW, güç faktörü bir olan, yükseltici tipte bir AGK ( Anahtarlamalı Güç Kaynağı) için EMG (Elektromanyetik Girişim) filtresi tasarlanmıştır. EMG filtresi tasarımı için kolay uygulanabilir bir yöntem sunulmuştur. Bu yöntem, gürültü kaynağının filtresizken ilettiği gürültü seviyesini ve bu gürültünün OM (Ortak Mode) ve FM (Farksal Mod) bileşenlerine ayrılmasını taban almıştır. İletilen gürültüyü, bileşenlerine ayırmak için CISPR'm OM ve FM gürültülerini ölçmekte uyguladığı bir frekans ayrımı göz önünde bulundurulmuştur. Bu ayrım, OM gürültülerinin 1.605 MHz'den büyük frekanslarda ölçülmesini öngörmektedir. Bu ayrım esas alınarak yapılan filtre tasarımından sonra, değerleri saptanmış devre elemanları İle bir numune filtre imal edilmiş, kıyıcıya bağlanmış ve test edilmiştir. Test sonuçlan ve bilgisayarda yapılmış simulasyon sonuçlan devre tasarımını doğrulamıştır. Tasarlanmış bir EMG filtresinden istenilen sonuçların alınamamasının sebepleri, filtre içi yerleşim, kablo bağlantıları, empedans uyumsuzluğu ve kullanılan devre elemanlarının özellikleri bakımından incelenmiştir.
Özet (Çeviri)
ABSTRACT EMI FILTER DESIGN FOR HIGH POWER HIGH FREQUENCY SMPS ERİŞTİREN Yalım M.S., Department of Electrical and Electronics Engineering Supervisor: Dr. Işık ÇADIRCI June 1998, 134 pages In this study, an EMI (Electromagnetic Interference) filter is designed for a unity power factor boost converter, having a switching frequency of 20 KHz and operating at 4 KW output power. A very practical EMI filter design procedure is presented. This procedure is based on base-line (i.e. without filter) conducted EMI measurements and separation of these measured conducted EMI to CM (Common Mode) and DM (Differential Mode) parts. In order to separate the measured conducted EMI into CM and DM parts, the recommendation stated in CISPR 16 is taken as basis, which states that CM conducted EMI should be measured above 1.605 MHz. Following the design of the filter, a prototype EMI filter is implemented and tested on the actual system Both the simulation of the designed EMI filter and the test results verified the design. The possible reasons for a designed filter not to work as desired are discussed in terms of filter layout, impedance mismatch and components used.
Benzer Tezler
- A clinical system for acquisition of averaged and single trial evoked potentials
Averajlanmış ve tek kayıtlık uyarılmış potansiyellerin kayıt ve ölçümü için klinik amaçlı bir sistem tasarımı ve gerçeklenmesi
HAKKI SARP ORAL
Yüksek Lisans
İngilizce
1996
Elektrik ve Elektronik MühendisliğiÇukurova ÜniversitesiDOÇ. DR. SALİU SOKOL
- Biyolojik işaretler için adaptif gürültü azaltma sistemi
Adaptive noise canceller for biological signals
AYDIN AKAN
Yüksek Lisans
Türkçe
1991
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiPROF.DR. ERTUĞRUL YAZGAN
- EMG işaretlerinden motor birim aksiyon potansiyellerinin ayrıştırılması
Decomposition of motor unit action potantials from EMG signals
İBRAHİM MUSTAFA EKİN
Yüksek Lisans
Türkçe
1997
Elektrik ve Elektronik MühendisliğiKaradeniz Teknik ÜniversitesiElektrik-Elektronik Mühendisliği Ana Bilim Dalı
YRD. DOÇ. DR. TEMEL KAYIKÇIOĞLU
- EKG ve EMG sinyallerinin yüksek duyarlıklı olarak ölçülmesi
High sensitive measurement of ECG and EMG signals
METİN YILDIZ
Yüksek Lisans
Türkçe
2000
Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolGazi ÜniversitesiElektronik ve Bilgisayar Eğitimi Ana Bilim Dalı
DOÇ. DR. F. NİHAL GÜLER
- General purpose PC-based biopotential data acquisition system
Genel amaçlı PC-tabanlı biyo-potansiyel veri toplama
MUSTAFA MİHMANLI
Yüksek Lisans
İngilizce
2000
Tıbbi BiyolojiBoğaziçi ÜniversitesiBiyomedikal Mühendisliği Ana Bilim Dalı
DOÇ. DR. HALİL ÖZCAN GÜLÇÜR