Volümetrik ark tedavisi (VMAT) kullanarak tüm vücut ışınlaması ve tüm kemik iliği ışınlamasının dozimetrik karşılaştırılması
Dosimetric comparison of total body irradiation and total marrowirradiation using volumetric arc therapy (VMAT)
- Tez No: 755940
- Danışmanlar: DOÇ. DR. CANDAN DEMİRÖZ ABAKAY
- Tez Türü: Yüksek Lisans
- Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
- Anahtar Kelimeler: Kemik iliği, Lenfoma, Lösemi, Neoplazmlar, Radyasyon onkolojisi, Radyometri, Radyoterapi, Tüm vücut ışınlaması, Bone marrow, Lymphoma, Leukemia, Neoplasms, Radiation oncology, Radiometry, Radiotherapy, Whole body irradiation
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Bursa Uludağ Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Radyasyon Onkolojisi Ana Bilim Dalı
- Bilim Dalı: Sağlık Fiziği Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Tüm vücut ışınlaması (TVI), lösemi, lenfoma, otoimmün hastalıkları ve multipl miyelom hastalarını tedavi etmek için, kemik iliği transplantasyonunun bir parçası olan özel bir radyoterapi tekniğidir. Nakilden sonra hastanın bağışıklık sistemini baskılamak, donör kemik iliğinin reddedilmesini önlemek ve sağlıklı hücrelerin bölünmesine uygun ortam hazırlanması için kullanılmaktadır. Bu çalışmasının amacı, volümetrik ark tedavisi (VMAT) kullanarak, tüm vücut ışınlaması (TVI) ve tüm kemik iliği ışınlaması (TKI) doz dağılımını araştırmaktır. Bunun için insan doku eşdeğerine benzer malzemelerden yapılmış rando fantomu kullanılmıştır. Rando fantomun BT görüntüleri 2 mm kesitler halinde çekilmiş ve BT görüntüleri, Monte Carlo doz hesaplama algoritması kullanılarak konturlama ve tedavi planlama için, Monaco sürüm 5.1'e aktarılmıştır. TVI için, akciğer ve lensleri koruyarak tedavi planı hazırlanırken TKI için, beyin, gözler, ağız boşluğu, akciğerler, kalp, böbrekler, karaciğer, dalak, mide, mesane, rektum ve bağırsaklar korunarak plan hazırlanmış ve hazırlanan planlar dozimetrik olarak karşılaştırılmıştır. VMAT-TVI ve VMAT-TKI planları için tedavi öncesi kalite kontrolü, Octavius 4D fantom kullanılarak gerçekleştirilmiştir. Planlanan ve verilen doz arasındaki doz doğruluğu, her 3 düzlemde de 3 mm ve %3 kriterleri ile gama indeksi analizi kullanılarak değerlendirilmiştir. İzomerkezlerin birleşimleri arasındaki doz hesaplaması ve dağılımı doğrulanmıştır. Çalışmada, her iki plan için tedavi öncesi ölçüm sonuçları ve tedavi planlama sisteminde elde edilen sonuçlar, TKI TVI'si ile karşılaştırıldığında, risk altındaki organ (RAO) dozlarında belirgin azalma olduğu gözlemlenmiştir. Özellikle sağ ile sol akciğer dozları sırasıyla yaklaşık olarak %20 ve %28 oranında azalmıştır. TVI'da ise Akciğer toksisitesi ana sınırlayıcı faktör olduğundan, bu azalmanın yaşam kalitesini daha da iyileştirebileceği ve klinik gereklilik olduğunda daha yüksek dozlara izin verebileceği görüşüne varılmıştır. İki tekniğin karşılaştırılması sonucunda %3-3 mm analiz için ortalama PTV γ indeksi %1'den az olduğu gözlenmiş, planlanan ve uygulanan dozlar arasında oldukça hassas doz dağılımları gözlenmiştir. Kritik organları korumada, TKI'nin üstünlüğü gözlemlenmiştir.
Özet (Çeviri)
Whole body irradiation (TVI) is a specialized radiotherapy technique that is part of the conditioning of bone marrow transplantation to treat patients with leukemia, lymphoma, autoimmune diseases, multiple myeloma. It is used to suppress the immune system of the patient after transplantation, to prevent rejection of the donor bone marrow and to prepare a suitable environment for the division of healthy cells. The aim of this study is to investigate the dose distribution of whole body irradiation (TVI) and whole bone marrow irradiation (TKI) using volumetric arc therapy (VMAT). For this, the rando phantom made of materials similar to the human tissue equivalent was used. First, CT images of the rando phantom are taken in 2 mm sections and the CT images are transferred to Monaco version 5.1 for contouring and planning using the Monte Carlo dose calculation algorithm. While the plan for TVI was prepared by preserving the lungs and lenses, the plan was prepared for TKI by preserving the brain, eyes, oral cavity, lungs, heart, kidneys, liver, spleen, stomach, bladder, rectum and intestines, and the prepared plans were compared dosimetrically. Quality assurance for VMAT-TVI and VMAT-TKI plans was performed using the Octavius 4D phantom. Dosage accuracy between the planned and delivered dose was evaluated using gamma index analysis with 3 mm and 3% criteria in all 3 planes. Dose calculation and distribution between junctions of isocenters were confirmed. As a result of this study, when the measurement results for both plans and the results obtained in the treatment planning system are compared with TKI, TVI, it is observed that there is a decrease in OAR doses, and the mean right and left lung doses are approximately 20% and 28% less, respectively. As lung toxicity is the main limiting factor for TVI, this reduction may further improve quality of life and allow higher doses when clinically necessary. As a result of these studies, the mean PTV γ index was observed to be less than 4% for the 3-3% mm analysis, and very precise dose distributions were observed between the planned and administered doses.
Benzer Tezler
- Lokalize prostat kanserinde stereotaktik vücut radyoterapi tedavi planlarının dozimetrik karşılaştırılması
Dosimetric comparison of stereotactic body radiotherapy treatment plans in localized prostate cancer
AHMET MURAT ŞENIŞIK
Yüksek Lisans
Türkçe
2020
Radyoloji ve Nükleer Tıpİstanbul ÜniversitesiTemel Onkoloji Ana Bilim Dalı
DR. ÖĞR. ÜYESİ MURAT OKUTAN
- Diyagnostik bilgisayarlı tomografi temelli palyatif radyoterapi planlamanın dozimetrik değerlendirilmesi
Başlık çevirisi yok
EMRE KARAMAN
Tıpta Uzmanlık
Türkçe
2026
Radyasyon OnkolojisiEge ÜniversitesiRadyasyon Onkolojisi Ana Bilim Dalı
PROF. DR. DENİZ YALMAN
- Akciğer stereotaktik vücut radyoterapisinde, hacimsel modüle edilmiş ark tedavisi (VMAT) ile dinamik konformal ark tedavisi (DCAT) arasında dozimetrik parametrelerin karşılaştırılması
Comparison of dosimetric parameters between volumetric modulated arc therapy (VMAT) and dynamic conformal arc therapy (DCAT) in lung stereotactic body radiotherapy
EBRAR BEZİRGANOĞLU
Yüksek Lisans
Türkçe
2025
Radyasyon Onkolojisiİstanbul Aydın ÜniversitesiSağlık Fiziği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ EYLEM GÜLCE ÇOKER
- Düşük risk prostat kanserinde yoğunluk ayarlı fraksiyone radyoterapi ile stereotaktik vücut radyoterapisinin dozimetrik karşılaştırılması
Dosimetric comparison of intensity-modulated fractional radiotherapy and stereotactic body radiotherapy in low-risk prostate cancer
ONUR SANCAR
Yüksek Lisans
Türkçe
2023
Radyasyon OnkolojisiKaradeniz Teknik ÜniversitesiSağlık Fiziği Ana Bilim Dalı
DOÇ. DR. EMEL HACIİSLAMOĞLU
- Erken evre küratif radyoterapi yapılan prostat kanserli haslarda iki farklı foton enerji kullanarak volumetrik ayarlı ark terapi tekniği ile flattening filter kullanılan ve kullanılmayan planların dozimetrik karşılaştırılması
Dosimetric comparison of plans with and without flattening filter using volumetric modulated arc therapy technique using two different photon energies in prostate cancer patients undergoing early stage curative radiotherapy
SEDAT KURT
Yüksek Lisans
Türkçe
2025
Radyasyon OnkolojisiTrakya ÜniversitesiSağlık Fiziği Ana Bilim Dalı
PROF. DR. HASAN MURAT ÇALOĞLU