quantitative Imaging with Y-90 Bremsstrahlung SPECT/CT (Single Positron Emission Computed Tomography)

Kantitatif Y-90 Bremsstrahlung SPECT/BT (Tek Foton Emisyon Tomografisi/Bilgisayarlı Tomografi) Görüntülemesi

  1. Tez No: 754706
  2. Yazar: SEVAL BEYKAN
  3. Danışmanlar: PROF. DR. MİCHAEL LASSMAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2014
  8. Dil: İngilizce
  9. Üniversite: Ruprecht-Karls-Unıversıtat-Heıdelberg
  10. Enstitü: Yurtdışı Enstitü
  11. Ana Bilim Dalı: Sağlık Fiziği Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Amaçlar: Bu çalışmanın amacı, çeşitli parametrelerin Y-90 kantitatif SPECT/BT görüntülemesi üzerindeki etkisini araştırmaktır.Bu amaçla; kolimatörlerin (yüksek enerjili ve orta enerjili kolimatör),enerji penceresinin ve rekonstrüksiyon ayarlarının görüntü kontrastı, görüntü gürültüsü, kontrast geri kazanım katsayısı, varyasyon katsayısı ve ilgi hacimlerinin (VOls) göreceli geri kazanım katsayısı üzerindeki etkisini inceleyen bir fantom çalışması yapıldı. Yöntemler:Görüntü kalitesini ölçmek için, çapları 10 mm ile 37 mm arasında değişen 6 küre içeren NEMA NU2-2001 PET/SPECT-Phantom kullanıldı. Her küre, kalibre edilmiş bir doz kalibratörü ile ölçülen aynı aktivite konsantrasyonu (1.59 MBq/ml) ile doldurulmuştur. Kalibrasyon için yaklaşık 79 MBq Y-90 içeren 50 ml'lik bir şişe kullanılmıştır. SPECT/BT verileri birkaç farklı çekim parametresi, iki farklı rekonstrüksiyon protokolü (2D OSEM ve 3D FLASH) ve 2 farklı kolimatör seti (yüksek enerjili ve orta enerjili kolimatör) kullanılarak elde edildi. BT tabanlı atenüasyon düzeltmesi uygulanmış ve her bir enerji penceresi aralığı için kalibrasyon sabitleri hesaplanmıştır. Birleşik enerji pencereleri için uygulanan atenüasyon düzeltmesinin görüntü üzerindeki etkisi araştırılmıştır. Görüntü kalitesi parametreleri olarak; kontrast (C[%]), kontrast geri kazanım katsayısı (QH), varyasyon katsayısı (CV), görünürlük (VH) ve sinyal gürültü Oranı (SNR),Y-90 ile görüntüsü alınan küreler ve şişe için her bir enerji penceresi aralığı, her bir kolimatör ve her rekonstrüksiyon için hesaplanıp karşılaştırılmıştır.Tüm enerji penceresi aralıkları (50-86, 86-106, 106-150, 150-195, 195-300, 302-650, 50-106, 106-195, 86-195, 50- 195, 50-300 keV), kolimatörler ve yrekonstrüksiyon algoritmaları için kürelerdeki toplam sayım sayısına karşılık gelen aktivite konsantrasyon oranları (CA-Ratio) ile küreler ve kullanılan şişe için spesifik sayım değerleri karşılaştırıldı. Ayrıca küreler ve şişe arasındaki toplam sayım ve aktivite oranları arasındaki ilişki araştırıldı. Sonuçlar: CV için en iyi enerji penceresi 50-195 keV olarak belirlenirken, C[%], QH, VH ve SNR için en iyi enerji penceresi 86-106 keV olarak belirlenmiştir. Kullanılan kolimatörler ve rekonstrüksiyon yöntemleri değerlendirildiğinde, yüksek enerjili kolimatör ile 2D OSEM algoritması ile yapılan ölçümler daha iyi sonuçlar göstermiştir ( yüksek C [%], QH, VH ve SNR, düşük CV). Küre başına en iyi CA-Oranları (birden büyük olmaması gerekir) HEGP kolimatörü kullanıldığında 86-106 keV enerji penceresinde gözlenmiştir. Birleşik enerji pencereleri için uygulanan atenüasyon düzeltmesinin görüntü üzerinde herhangi bir etkisi gözlemlenmemiştir. MEGP kolimatörü için hesaplanan kalibrasyon sabiti HEGP'den daha yüksektir. Küreler ve şişe arasındaki toplam sayım ve aktivite oranları arasındaki tutarsızlık büyük olasılıkla değişken Bremsstrahlung Işınması veriminden kaynaklı olarak değerlendirilmiştir. Sonuçlar: Kullanılan kolimatör tipinin, seilen enerji penceresinin ve rekonstrüksiyon algoritmasının Y-90 Bremsstrahlung görüntü kalitesi üzerinde önemli etkileri vardır. Belirlenen parametrelere dayalı en iyi görüntü kalitesi için, yüksek enerjili bir kolimatör kullanılması, 2D OSEM rekonstrüksiyon algoritması kullanılması ve 86-106 keV enerji penceresi aralığının seçilmesi önerilmektedir.

Özet (Çeviri)

Objectives: The aim of this study is to investigate the influence of various parameters on the reliability of quantitative Bremsstrahlung SPECT/CT. For this purpose; a phantom study was performed studying the influence of collimators (high-energy and medium-energy collimator), energy window and reconstruction settings on image contrast, image noise, the contrast recovery coefficient, the coefficient of variation, and the relative recovery coefficient of volumes of interests (VOIs). Methods: For measuring the image quality the NEMA NU2-2001 PET/SPECT-Phantom was used containing 6 spheres with diameters between 10 mm and 37 mm. Each sphere was filled with the same activity concentration (1.59 MBq/ml) measured by a calibrated dose calibrator. A 50 ml bottle with approximately 79 MBq of Y-90 was used for calibration. SPECT/CT data were acquired by using several different acquisition parameters, two different reconstruction protocols (2D OSEM and 3D FLASH) and 2 different collimator sets (high-energy and medium-energy collimator). CT-based attenuation corrections were applied and calibration constants were measured for each energy window. The influence when changing the order of attenuation correction for the combined energy windows was investigated. As image quality parameters; the results of contrast (C[%]), the contrast recovery coefficient (QH), coefficient of variation (CV), the visibility (VH) and the signal noise ratio SNR of the different spheres and the bottle in Y-90 SPECT-CT images were calculated and compared for both collimators and reconstruction algorithms in each energy window settings. For all energy window ranges (50-86, 86-106, 106-150, 150-195, 195-300, 302-650, 50-106, 106-195, 86-195, 50-195, 50-300 keV), collimators and reconstruction algorithms, the total number of counts-to-activity concentration ratios (CA-Ratio) per spheres and specific numbers of counts for both spheres and the bottle were compared. In addition the relationship between spheres and the bottle related to total count ratios and activity ratios were investigated. Results: The best energy window for CV was determined as 50-195 keV while the best energy window for C [%], QH, VH and SNR was established as the window 86-106 keV. As for the comparison of the collimators and reconstruction methods, the measurements with 2D OSEM algorithm with the high-energy collimator showed better results (smaller CV with higher C [%], QH, VH, and SNR). The best results of CA-Ratios per spheres (which shouldn't be larger than one) were observed in the energy window 86-106 keV for the HEGP collimator. Changing the order of processing for the combined energy windows has no influence on the image quality parameters. Calibration constants in MEGP collimator were higher than HEGP. The relationship between Spheres and the Bottle related to Total Count Ratios and Activity Ratios were inconsistent mostly likely caused by varying Bremsstrahlung yields. Conclusions: The collimator type used, the applied energy window range and the reconstruction algorithm have substantial effects on Y-90 Bremsstrahlung image quality. For the best image quality based on determined parameters, the 86-106 keV energy windows in conjunction with the 2D OSEM reconstruction algorithm using a high energy collimator are suggested.

Benzer Tezler

  1. Tekstil boyamacılığında atık flottede boyama imkanları üzerine araştırma

    Başlık çevirisi yok

    MEHMET YAKARTEPE

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Tekstil ve Tekstil MühendisliğiEge Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. KERİM DURAN

  2. Çiğit ve ayçiçek yağlarının doğal antioksidan içerikleri ile bu yağların stabilitelerinin arttırılmaları üzerinde araştırmalar

    Başlık çevirisi yok

    ALİ KEMAL YALNIZ

    Doktora

    Türkçe

    Türkçe

    1985

    Gıda MühendisliğiEge Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    PROF. DR. MAHİR ÇOLAKO¦LU

  3. Çekirdeksiz kuru üzümlerde aflatoksin B1, B2, G1, G2 tayini için mevcut bazı metotların karşılaştırılması üzerinde bir çalışma

    Başlık çevirisi yok

    DİLEK BOYACIOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gıda MühendisliğiEge Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. MERAL GÖNÜL

  4. Bornova (İzmir) koşullarında çeşitli kültür bitkilerinde zarar yapan Dolycoris baccarum (L.) (Heteroptera: Pentatomidae)'un biyolojisi ve ekolojisi üzerinde araştırmalar

    Investigations on the biology and ecology of Dolycoris baccarum (L.) (Heteroptera: Pentatomidae) which attacks to various plants of economic importance at Bornova (İzmir)

    YUSUF KARSAVURAN

    Doktora

    Türkçe

    Türkçe

    1986

    ZoolojiEge Üniversitesi

    Bitki Koruma Ana Bilim Dalı

    PROF. DR. FEYZİ ÖNDER

  5. Mevcut kaplıca yerleşmelerinin iyileştirilmesini etkileyen faktörler ve Yeni Kaplıca örneği

    Adjustment principles of spas in Turkey, Yeni Kaplıca being the sample

    DOĞAN ÜMİT YÜCEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İşletmeGazi Üniversitesi

    Mimarlık Ana Bilim Dalı

    DOÇ. DR. YÜKSEL ERDEMİR