Geri Dön

Sabit protez ölçülerinde ölçü kaşığına uygulanan kuvvet miktarının ve akıcı kıvamlı ölçü maddesi kalınlığının ölçü doğruluğuna etkisi

The effect of the amount of force applied to the impression tray and the thickness of the light body on the impression accuracy in fixed prosthesis impression

  1. Tez No: 754182
  2. Yazar: EKİN BENGİSU ERGÜL
  3. Danışmanlar: PROF. DR. OSMAN CUMHUR SİPAHİ
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: CAD/CAM, Dental materyaller, Dental protezler, Diş protezi tasarımı, Protezler ve implantlar, Ölçü, CAD/CAM, Dental materials, Dental prosthesis, Dental prosthesis design, Prostheses and implants, Measure
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Sağlık Bilimleri Üniversitesi
  10. Enstitü: Gülhane Diş Hekimliği Fakültesi (ankara)
  11. Ana Bilim Dalı: Protez Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı, prepare edilmiş dişlerden A Tipi ve C Tipi Silikon ölçü materyalleri ile ölçü alımı esnasında ölçü kaşığına uygulanan ve kişiden kişiye değişkenlik gösteren parmak basıncı miktarının ölçü doğruluğuna olan etkisini değerlendirmek ve ölçü alımı aşamasında uygulanacak optimal kuvveti belirlemektir. Çalışmanın bir diğer amacı da çift karıştırma tekniğinde son aşamada kullanılan akıcı kıvamlı ölçü maddesi kalınlığının ölçü doğruluğuna olan etkisini belirlemek ve optimal kalınlık miktarını saptamaktır. Çalışmada kullanılan başlangıç ana modeli CAD/CAM yöntemiyle tasarlandı ve üretildi. Akıcı kıvamlı ölçü materyali için yer sağlayacak farklı kalınlıklarda plastik yer tutucular üretildi. Ana model laboratuvar tipi tarayıcıda taranarak dijital referans model elde edildi. Elde edilen ana model tarama verileri tersine mühendislik programı kullanılarak çakıştırıldı. Ölçü materyali (A tipi ve C tipi silikon), boşluk ve kuvvet kombinasyonu dahilinde grupların oluşturularak (24 grup) ana modelden her bir grup için 8'er adet ölçü alındı. Elde edilen 196 adet ölçüye Tip IV dental alçı dökülmesi ve model elde edildi. Modellerin laboratuvar tipi tarayıcı ile tarandı ve elde edilen verilerin aralıklı, bitişik ve tam ark olacak şekilde üç farklı şekilde hazırlandı. Ana model STL dosyaları ile bire bir çakıştırma yaparak Sapma miktarlarının hesaplandı ve edilen veriler istatistiksel olarak incelendi. Çalışmanın sonuçlarına göre çalışma modellerinin tümü, başlangıç ana modeline göre boyutsal anlamda farklılık gösterdi (p<0.05). Materyalin A Tipi Silikon veya C Tipi Silikon olmasının akıcı kıvamlı ölçü materyali için bırakılan boşluk miktarının ve ölçü alımı esnasında uygulanan kuvvet büyüklüğünün ölçülerin ve çalışma modellerinin doğruluğunu etkilediği görüldü. Tam ark dişli restorasyonların veya kısa dişsiz boşlukların ölçüleri alınırken akıcı kıvamlı ölçü materyali için yer bırakılmaksızın 35N kuvvet uygulanmasının ölçü ve model doğruluğunu anlamlı derecede arttırdığı saptandı. C Tipi silikon ile alınan ölçülerde düşük kuvvet uygulanmasının ve akıcı kıvamlı ölçü materyali için 1.5 mm boşluk bırakılmasının ölçü ve model doğruluğunu arttırdığı belirlendi. Aralıklı dişsiz boşlukların ölçüsünde A Tipi silikonların anlamlı olarak daha doğru ölçüler ve alçı modeller elde edilmesini sağladığı görüldü. Aralıklı dişsiz boşluklarda C Tipi silikon ile ölçü alırken akıcı kıvamlı ölçü materyali için 1.5 mm kadar yer bırakılmasının ve düşük kuvvetler uygulanmasının doğruluğu daha yüksek ölçü ve modellerin elde edilmesini sağladığı tespit edildi.

Özet (Çeviri)

The aim of the present study was to evaluate the effect of finger pressure magnitude applied on impression trays while making impressions with type A and type C silicone impression materials, and to determine the optimal force in order to obtain highly accurate and precise impressions. The second aim was to determine the effect of light body impression material's thickness used in double mixing technique on the accuracy of impressions and to determine the optimal thickness amount. The master model used in the study was designed and produced using CAD/CAM technology. Plastic spacers with different thicknesses were produced to provide space for the light body material. The digital reference model was obtained by scanning the master model with a laboratory scanner. The master model scan data was superimposed using reverse engineering program. Twenty four groups (n=8) were defined with the combination of 4 spacer thickness and 3 different force magnitudes for 2 different impression materials. Type IV plaster was cast and 196 stone models were obtained. The models were scanned with an extraoral scanner and recorded as STL file. STL files were transformed to 3D Design program (Meshmixer) and modified according to measurement regions; full arch (all abutments on the master model), long (4 abutments representing tooth prepared for long span fixed prostheses) and short (representing 3 adjacent abutments). Deviations were calculated by superpositioning the master model's STL files and 192 experimental models' STL files. Obtained data were statistically analyzed. All models showed significantly different dimensions compared to the initial master model (p<0.05). The amount of space left for the light body material and the magnitude of force applied during impression procedure significantly affected the accuracy of impressions and experimental models for both type A and type C silicones (p<0.05). Highest accuracy and precision values were obtained with 35N force and 0 mm (zero) space left for light body material for the impression of full-mouth fixed restorations (or short-span fixed prosthesis). Significantly highest accuracy and precision values were obtained with lower force (15N) and 1.5 mm space left for light body for type C silicone (p<0.007). Type A silicone provided significantly more accurate plaster models for long span (multi pontic) fixed prostheses (p<0.00). While making impression with C type silicone for long span fixed prosthesis, leaving a space of 1.5 mm for the light body material and applying lower forces (15N) enabled significantly highly accurate models (p<0.005).

Benzer Tezler

  1. İmplant destekli sabit bölümlü protezlerde dijital ve konvansiyonel ölçü yöntemlerinin karşılaştırılması

    Comparison of digital and conventional impression methods in implant supported fixed partial dentures

    İSMAİL KILIÇ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2018

    Diş HekimliğiSelçuk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. OĞUZ ERASLAN

  2. Üst tam protez yapımında geleneksel ve dijital ölçü alınarak hazırlanan kaide plaklarının doku uyumunun karşılaştırılması

    Comparison of tissue surface adaptation of maxillary denture bases fabricated using conventional and digital impression techniques

    SALİHA ŞENOL TEKDEMİR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiHacettepe Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. NESRİN ANIL

  3. İmplant destekli tam ark tek parça üst yapı üretiminde ağıziçi dijital ölçü yönteminin değerlendirilmesi

    Evaluation of intraoral scanning technique in fabrication of implant supported full arch fixed screw retained superstructure

    MERVE VAROL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiHacettepe Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. KIVANÇ AKÇA

  4. Değişik şekillerde tasarımlanan mandibular serbest sonlanan bölümlü protezlerde kuvvet iletiminin holografik interferometri ile değerlendirilmesi

    Evaluation of load transmission by holographic interferometry in mandibular distal-extension removable partial dentures with various designs

    MURAT SABANCI

    Doktora

    Türkçe

    Türkçe

    2000

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. A. KEVSER AYDIN

  5. Sabit protez ölçülerinde yöntem ve zamana bağlı boyutsal değişkenlerin incelenmesi

    Başlık çevirisi yok

    BÜLENT SARIOĞLU

    Doktora

    Türkçe

    Türkçe

    1985

    Diş HekimliğiHacettepe Üniversitesi

    Protez Ana Bilim Dalı

    DOÇ. DR. OKTAY KURAL