Geri Dön

Mixed-mode HPLC aplication of a nevly developed stationary phase basen on [2-(3,4-epoksisiklohekzil)etil]trimetoksisilan

[2-(3,4-epoksisikloheksil)etil]trimetoksisilan türevi yeni bir sabit fazın sentezi ve karma mod HPLC uygulamaları

  1. Tez No: 737835
  2. Yazar: MEHMET YAŞAR MUMİN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ HAYRİYE ARAL
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kimya, Chemistry
  6. Anahtar Kelimeler: Analiz teknikleri, Fazlar, Kromatografi-yüksek basınçlı-sıvı, Ters faz kromatografisi, Analysis techniques, Phases, Chromatography-high pressure-liquid, Reverse phase chromatography
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Batman Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu tez çalışmasında, daha önce BTÜBAP-2018- FED-3 Projesi kapsamında sentezlenip HPLC kolonu haline getirilen Si-Ch-IlePBA sabit fazın HPLC ile hidrofilik etkileşimi incelendi. Bir kapling reaktifi olan [2-(3,4-epoksisikloheksil)etil]trimetoksisilandan yola çıkılarak silika tabanlı yeni bir karma- mod sabit fazı sentezlendi ve hidrofilik etkileşim/ters fazlı yüksek performanslı sıvı kromatografisi (HPLC) etkinliği incelendi. Polar amid, amin ve alkol gruplarının yanı sıra polar olmayan alifatik ve aromatik grupları taşıyan yeni sabit faz, [2-(3,4-epoksisikloheksil)etil]trimetoksisilan ve izolösin amino asitinden başlayarak sentezlendi ve yapısı elementel analiz, kızılötesi spektroskopi(FTIR), taramalı elektron mikroskobu (SEM) ve katı hal 13C nükleer manyetik rezonans (CPMAS NMR) ile karakterize edildi. Farklı polaritelere sahip bazı aromatik bileşiklerin, hidrofilik etkileşim sıvı kromatografisi (HILIC) ve ters faz (RP) koşullarında ayrımı incelendi ve başarılı bir ayırma sonucu elde edildi. Yeni sabit fazın HILIC modundaki etkinliğini incelemek için suda çözünen vitaminler ve nükleobazlar test edildi. Altı tane suda çözünen vitamin, gradient elüsyonla, beş tane nükleobaz, izokratik elüsyonla başarılı bir şekilde ayrıldı. Sabit fazın sübstitüe benzoik asitler, klorlu herbisitler, alkil benzenler gibi bir seri orta ve zayıf polarlıkta ve polar olmayan küçük bileşiklere ve polar/polar olmayan aromatik bileşiklerin bir karışımına karşı ters faz (RP) etkinliği incelendi ve başarılı ayırmalar elde edildi. İzokratik elüsyon ile ayrılan tüm analitler için alıkonma faktörü, teorik tabaka sayısı ve pik asimetri faktörü hesaplandı. Geleneksel C18 ve ticari HILIC kolonları ile kıyaslandığında, yeni sabit fazın hem HILIC hem de RPLC performansı sergilediği gözlendi ve böylece daha geniş perspektifte analit sınıflarının ayrımı incelendi.

Özet (Çeviri)

A new silica-based mixed-mode stationary phase derived from [2-(3,4-epoxycyclohexyl)ethyl]trimethoxysilane as a coupling reagent was synthesised and evaluated for hydrophilic interaction/reversed-phase high-performance liquid chromatography (HPLC). The new stationary phase bearing polar amide, amine and alcohol groups as well as nonpolar aliphatic and aromatic groups was synthesised starting from [2-(3,4-epoxycyclohexyl)ethyl]trimethoxysilane and isoleucine amino acid and characterized by elemental analysis, infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and solid-state 13C nuclear magnetic resonance (CPMAS NMR). Several aromatic compounds having different polarities were tested for hydrophilic interaction liquid chromatography (HILIC) and reversed phase (RP) condition and successful separation could be achieved. Water soluble vitamins and nucleobases were tested to investigate effectiveness of the new column on HILIC mode. The six water soluble vitamins separated successfully by a gradient elution, and five nucleobases were separated by an isocratic elution. A number of moderately and weakly polar and nonpolar small compounds such as substituted benzoic acids, chlorinated herbicides, alkyl benzenes and a mixtures of polar/nonpolar aromatic compounds were tested for the RP condition and separated successfully. The retention factor, theoretical plate number and peak asymmetry factor were calculated for all of the analytes separated by isocratic elution. Compared to traditional C18 and commercial HILIC columns, the new stationary phase exhibited both HILIC and RPLC performance, and the scope of analyte separation was thus enlarged.

Benzer Tezler

  1. Karıştırıcılar ve karıştırma kabındaki akım olaylarının incelenmesi

    Başlık çevirisi yok

    NADİR İLTEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Makine MühendisliğiUludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ.DR. ÖMER SAMİH MERTBAŞ

  2. Marmara bölgesindeki kavun ve karpuz yetiştiriciliğinin bugünkü durumu, sorunları ve öneriler

    The Status of melon and water melongrowing in Marmara region at present and its Problems and recommedations

    MEHMET GÜLER

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    ZiraatUludağ Üniversitesi

    Bahçe Bitkileri Ana Bilim Dalı

    DOÇ. DR. VEDAT ŞENİZ

  3. Üzüm sularının pastörizasyonu ve kontsantresi sırasında hidroksimetilfurfural oluşumu üzerinde bir araştırma

    Başlık çevirisi yok

    ŞERİFE ŞAHİN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gıda MühendisliğiEge Üniversitesi

    Tarım Ürünleri Teknolojisi Ana Bilim Dalı

    DOÇ. DR. AYDIN URAL

  4. Computer aided design of lumped and distributed broadband matching and filtering networks

    Başlık çevirisi yok

    ADNAN KÖKSAL

    Yüksek Lisans

    İngilizce

    İngilizce

    1987

    Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. NEVZAT YILDIRIM

  5. Pastörizasyondan sonra kültür ilavesinin ekşi kremadan yapılan tereyağlarının özelliklerine etkisi üzerine bir araştırma

    Başlık çevirisi yok

    SERAP TAMER

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gıda MühendisliğiEge Üniversitesi

    Süt Teknolojisi Ana Bilim Dalı

    YRD. DOÇ. DR. ERGİN OKTAR