Geri Dön

Modifiye mekik koşusu testinin güvenirliği ve geçerliği

Reliability and validity of the modified shuttle running test

  1. Tez No: 71079
  2. Yazar: ABDÜLKADİR HIZAL
  3. Danışmanlar: PROF. DR. FETHİ HEPER
  4. Tez Türü: Yüksek Lisans
  5. Konular: Spor, Sports
  6. Anahtar Kelimeler: Güvenirlik, Geçerlik, KAH, Laktat, Anaerobik Eşik. 20 m. Mekik Koşusu, Modifiye Mekik Koşusu. vuı, Anaerobik eşik, Güvenilirlik, Kalp hızı, Koşu, Laktatlar, Testler, Reliabilty, Validity, Hearth Rate, Lactate, Anaerobic Threshold, 20 m. Shuttle Run, Modified Shuttle Run. IX, Reliability, Heart rate, Running, Lactates, Tests
  7. Yıl: 1997
  8. Dil: Türkçe
  9. Üniversite: Anadolu Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Beden Eğitimi ve Spor Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Bu çalışmanın amacı, takım sporlarında maksimal Aerobik Gücü ve Anaerobik Eşik Koşu Hızının belirlenmesi amacı ile kullanılması düşünülen Modifiye Mekik Koşusu testinin güvenirliği ve geçerliğinin çalışmasıdır. Çalışmaya, Bayanlar Türkiye 1. Hentbol Liginde oynayan Anadolu Üniversitesi Spor Kulübünde yer alan 10 bayan hentbol oyuncusu (kaleciler hariç) Yaş : x = 21. 2± 1.9, boy uzunluğu: x = 167.7 ±9.5, vücut ağırlığı : x = 65.3 ±7.1 gönüllü olarak katılmışlardır. Bu çalışmada güvenirlik ve geçerlik ölçümü yapabilmek için denekler 1 hafta arayla 3 kez teste katılmışlardır. 1. teste tesadüfi yöntemle seçilen 5 denek' e Eurofit 20 m mekik koşusu (20 m MK) protokolü, 5 denek' e ise, 20 m MK testi protokulundaki hız değerlerine uygun modifiye mekik koşusu (MMK) testi uygulanmıştır. 2. testde denekler değişerek aynı testlere girmişlerdir. 3. testde ise yine tesadüfi yöntemle seçilen 7 deneğe MMK testi uygulanmıştır. Deneklerin dinlenik laktik asit (LA) ve kalp atım hızı (KAH) değerleri kaydedildikten sonra 8 km İr1, 10 km h"1, 11 km h_1 ve 12 km İr1 hızlarda 3'er dakika koşturulup aralarda 1 dk. dinlenme yapıldığı sırada kulak memesinden kan örneği alınarak Accusport laktat analizörü ve boehringer mannheim laktat kitlen ile LA ölçümleri yapılmıştır. Verilerin analizi SPSS paket programında değerlendirilmiş, tamamlayıcı istatistikler yapıldıktan sonra ölçümler arasındaki farklar Wilcoxon, eşleşmiş iki örnek testi ve bağımlı gruplarla T testi, ilişkiler pearson product moment kat sayısı ile araştırılmıştır. 0.05 anlamlılık düzeyi kullanılmıştır. Sonuç olarak, MMK testi geçerliği ve güvenirliği yüksek bir test olduğu bulunmuş hentbol gibi takım sporlarında aerobik gücü ve anaerobik eşik koşu hızını belirlemesinde kullanılabilecek bir testtir. (P<0,05).

Özet (Çeviri)

ABSTRACT This study aimed at investigating the reliability and the validity of the Modified Shuttle Running Test (MSR) which was thought to be used in measuring the maximal anaerobic strenght and anaerobic threshold running speed in team sports. 10 female professional handball players (excluding the goal-keepers) of the Anadolu University Sports Club participated in the study. (Age: x = 21.2 ± 1.9, height: x = 167.7+ 9.5, weight: x = 65.3 ±7.1) For measuring the reliability and the validity, subjects were taken into a set of three tests in a three weeks time. In the first test, randomly chosen 5 subjects were asked to carry aut a Eurofit 20 meters Shuttle Run (20 m SR) test which was appropriate to the speed values in 20 m SR test protocols. In the second test same tests were done by changing the two subject groups. Finally in the third test, among the 10 subjects, randomly choosen 7 were taken into a Modified Shuttle Running test. After the subjects' standard lactic asit (LA) and hear-rate speed values were recorded, they were asked to run four three-minute periods at the speeds of 8 km h*1, 10 km h_1, 11 km h_1, 12 km h_1. In every one-minute break after each period, Accusport lactate analyzer, Bochringer Mannheim lactate kits and LA measurements were done through the blood taken from subjects' earlobes. The results of the tests were analyzed by the SPSS computer programme and the complementary statistics were done. As the final step the differences and the relations between the results were analyzed by Wilcoxon's paired two subject tests and T tests for related groups, and Pearson Product Moment Coefficient respectively. As a result, MSR test is found to be a highly reliable and valid test to be used in measuring the anaerobic strenght and anaerobic threshold running speed in team sports (p < 0.05).

Benzer Tezler

  1. Dayanıklılığın değerlendirilmesinde mekik koşusunun güvenirliği ve geçerliği

    Reliability and validity of modified shuttle running test in the evaluation of aerobic endurance

    TAHİR HAZIR

    Doktora

    Türkçe

    Türkçe

    2000

    SporHacettepe Üniversitesi

    Spor Bilimleri ve Teknolojisi Bilim Dalı

    PROF. DR. CANER AÇIKADA

  2. Zihinsel özürlü çocuk ve gençlerin fiziksel durumlarını tesbit etmek amacıyla kullanılan motor testlerin kaçıncı tekrardan sonra öğrenilmiş, tam ve doğru olarak uygulanıyor kabul edilebileceği üzerine bir araştırma

    A Study on motor tests that are used to identify physical fitness on mentally retarded children and adults, can be acceptable after which repetition as to be learned, applied completely and accurately

    HATİCE OSUNLUK

    Yüksek Lisans

    Türkçe

    Türkçe

    1996

    Çocuk Sağlığı ve HastalıklarıHacettepe Üniversitesi

    PROF.DR. EMİN ERGEN

  3. Hepatik ensefalopatide parenteral amino asit infüzyon tedavisinin etkinliğinin araştırılması

    Başlık çevirisi yok

    MAHMUT ÖZTÜRK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1992

    GastroenterolojiUludağ Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    PROF. DR. FARUK MEMİK

  4. Modifiye michel-trombe duvarı uygulamasında çift amaçlı (konut ısıtması+sıcak su üretimi) yeni bir sistemin teorik ve deneysel incelenmesi

    Başlık çevirisi yok

    EKREM GÖKGÖZ

    Doktora

    Türkçe

    Türkçe

    1990

    EnerjiEge Üniversitesi

    Enerji Teknolojisi Ana Bilim Dalı

    PROF. DR. GÜRBÜZ ATAGÜNDÜZ