Geri Dön

İmplant üstü sabit protetik restorasyonlarda kullanılan farklı kaplama materyallerinin, stres dağılımına etkisi

The Effect of stress distribution of the veneering materials on the implant supported fixed prosthetic restorations

  1. Tez No: 69941
  2. Yazar: YALÇIN ÇİFTÇİ
  3. Danışmanlar: DOÇ. DR. ŞENAY CANAY
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: kaplama materyali, stres analizi, implant, sabit protetik restorasyon III, Dental implantlar, Dental materyaller, Dental stres analizi, Takma dişler, veneering materials, stress analysis, dental implant, fixed partial denture IV, Dental implants, Dental materials, Dental stress analysis, Dentures
  7. Yıl: 1998
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Protez Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Bu çalışmada, implant üstü sabit protetik restorasyonlarda kullanılan farklı kaplama materyallerinin implant, implant çevresi dokular ve protetik yapılarda oluşturduğu streslerin dağılımı incelenmiştir. Üç boyutlu sonlu elemanlar stres analiz yöntemi için porselen, metal, kompozit rezin, güçlendirilmiş kompozit rezin ve akrilik rezin kaplama materyallerinin kullanıldığı 11 361 düğüm noktası ve 54 598 elemana sahip beş farklı matematik model hazırlanmıştır. Analizlerde MARC K7.2 / Mentat 3.2 (MARC Analysis Research Corporation, USA) stres analiz programı kullanılmıştır. Kortikal kemikte, metal alt yapı marjini ve yüzeylerinde, kaplama materyali marjini ve yüzeylerinde referans düğüm noktaları belirlenmiştir. Bu noktalara dik, oblik ve yatay yönde uygulanan kuvvetler altında oluşan stres değerleri incelenmiştir. Oblik ve yatay yönde uygulanan kuvvetlerde oluşan stres değerlerinde dikey yönde uygulanan kuvvetlere kıyasla artışın olduğu gözlenmiştir. Kemik dokusunda oluşan stresler implantın boyun bölgesindeki kortikal kemikte yoğunlaşmıştır. Bu bölgede oluşan en yüksek stres değerleri metal ve porselenin kaplama materyali olarak kullanıldığı modellerde izlenirken, akrilik rezinde % 25 daha düşük stres değerleri elde edilmiştir. Güçlendirilmiş kompozit rezin materyallinin kullanıldığı modellerde ise porselen ve metalin kaplama materyali olarak kullanıldığı modellere göre % 15 daha düşük stres değerleri izlenmiştir. Porselen ve metalde, yerleştirilen implantların lingual yüzeylerinde oluşan stres değerleri kemiğin en yüksek dayanıklılık sınırlarına çok yakındır. Protetik üst yapıda, en yüksek stres değerleri restorasyonun marjin bölgesinde yoğunlaşmaktadır. Porselen kaplama materyali olarak kullanılınca marjin bölgesinde bazı referans düğüm noktalarında en yüksek dayanıklılık değerleri aşılmaktadır. Sonuç olarak, akrilik rezin, kompozit rezin ve güçlendirilmiş kompozit rezin kaplama materyallerinde oluşan stres değerlerinde azalmanın olduğu izlenmiştir.

Özet (Çeviri)

ABSTRACT In this study, the effect of various materials used in fabricating implant retained fixed partial dentures on stress distribution around peri-implant tissues and prosthetic components superstructures were investigated. Five different mathematical models consisting of 11.361 nodes and 54.598 elements were constructed to study porcelain, metal, composite resin, reinforced composite resin and acrylic resin veneering materials using three dimensional finite element stress analysis method. MARC K7.2 / Mentat 3.2 (MARC Analysis Research Corporation, USA) stress analysis software was used for the analyses. Reference points were determined on cortical bone, metal substructure margin and on veneer material surfaces, to where perpendicular, oblique and horizontal forces were applied. Stress values created by oblique and horizontal forces appeared to be higher than those created by vertical forces. Stress seemed to concentrate at the cortical bone around the cervical region of the implant. Metal and porcelain produced the highest stress values in this region. Stress created by acrylic resin and reinforced composite resin was less compared to porcelain and metal, 25 percent and 15 percent, respectively. Porcelain and metal produced stress values at the lingual implant sites reaching to the ultimate stress values of cortical bone. Stress distribution analyses of the prosthetic superstructures showed that highest values concentrated at the marginal region. In the case of porcelain, these values exceeded the ultimate strength values at certain marginal reference nodes. Lesser stress values were observed with acrylic resin, composite resin and reinforced composite resin materials.

Benzer Tezler

  1. İmplant destekli ağız içi protezlerinin başarısında oklüzyonun önemi

    Başlık çevirisi yok

    EMİN KAZIM ÖRGEV

    Doktora

    Türkçe

    Türkçe

    1997

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. AYDIN BIÇAKÇI

  2. Osseointegre implantlar çevresindeki subgingival mikrofloranın incelenmesi

    Başlık çevirisi yok

    IRMAK ÜNVER (ÇINAR)

    Doktora

    Türkçe

    Türkçe

    1997

    Diş HekimliğiMarmara Üniversitesi

    Periodontoloji Ana Bilim Dalı

    PROF. DR. SELÇUK YILMAZ

  3. Konus kuronlarda kullanım sonucu tutuculuk ve aşınmanın in vitro olarak incelenmesi

    In-vitro evaluation of retention and wear in conus crowns by usage

    FARİBORZ SAADAT

    Doktora

    Türkçe

    Türkçe

    1997

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. M. BABÜR CANİKLİOĞLU

  4. Meme implantının tipi, implant yüzey özellikleri ve yerleştirildiği bölgenin kapsül gelişimi üzerindeki etkileri

    The Effects of implant type, surface properties and placement site on the capsular development

    MASOUD SERADJMİR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2001

    Plastik ve Rekonstrüktif Cerrahiİstanbul Üniversitesi

    Plastik ve Rekonstrüktif Cerrahi Ana Bilim Dalı

    DOÇ.DR. OSMAN AKIN YÜCEL