Koklear implant ve işitme cihazı kullanıcılarında serbest alan işitme eşikleri ile işitsel uyarılmış kortikal potansiyellerin karşılaştırılması
Comparison of free field hearing thresholds and cortical auditory evoked potentials in cochlear implant and hearing aid users
- Tez No: 685682
- Danışmanlar: PROF. DR. AYŞE AYÇA ÇİPRUT
- Tez Türü: Yüksek Lisans
- Konular: Kulak Burun ve Boğaz, Otorhinolaryngology (Ear-Nose-Throat)
- Anahtar Kelimeler: Koklear implant, işitme cihazı, işitsel uyarılmış kortikal potansiyeller, serbest alan odyometri, Koklear implantlar, Odyoloji, Uyarılmış potansiyeller-işitsel, İşitme cihazları, İşitme eşiği, İşitme kaybı, Cochlear implant, hearing aid, cortical auditory evoked potentials, free field audiometry, Cochlear implants, Audiology, Evoked potentials-auditory, Hearing aids, Auditory threshold, Hearing loss
- Yıl: 2021
- Dil: Türkçe
- Üniversite: Marmara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Kulak Burun Boğaz Ana Bilim Dalı
- Bilim Dalı: Odyoloji ve Konuşma Bozuklukları Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışma ile, bireylerin koklear implanttan veya işitme cihazından gördükleri faydayı ölçmek ve odyoloğun yaptığı programlamaların değerlendirilebilmesi için serbest alan odyometri testine alternatif olarak İşitsel Uyarılmış Kortikal Potansiyeller (İUKP) testi ile frekansa özgü eşik bulmak ve her iki test arasındaki ilişkiyi incelemek amaçlanmaktadır. Gereç ve Yöntem: Araştırmanın örneklemini; Kİ kullanan yetişkin bireyler, İC kullanan yetişkin bireyler ve normal işiten yetişkin bireyler oluşturmaktadır. Her bir grup 20 katılımcıdan oluşacak şekilde 80 ayrı ölçüm yapılmıştır. İlk aşamada sessiz kabinde hoparlör aracılığıyla tüm grupların serbest alan işitme eşikleri ve konuşmayı fark etme eşikleri belirlenmiştir. İkinci aşamada, 500-1000-2000-4000 Hz'de tone burst uyaran ve /da/ konuşma uyaranı sunularak İUKP testi uygulanmıştır. Bulgular: İUKP test bataryasının normal işiten bireylerin oluşturduğu grup hariç tüm gruplarda serbest alan odyometri testi ile aralarında istatistiksel olarak anlamlı farklılık bulunmazken (p>0,05), normal işitenler de dahil tüm gruplarda anlamlı ilişki elde edilmiştir (p<0.05). Bland-Altman analizine göre serbest alan odyometri ile İUKP ölçümleri arasında tüm çalışma gruplarında uyum olduğu hesaplanmıştır. Sonuçlar: Kooperasyon zayıflığı sebebiyle davranışsal eşiği belirlenemeyen bireylerin koklear implant ve işitme cihazı performanslarını değerlendirebilmek için frekansa spesifik İUKP testi tutarlı ve güvenilirliği yüksek bir alternatiftir.
Özet (Çeviri)
Purpose: It is aimed to find frequency-specific threshold with Cortical Auditory Evoked Potentials test as an alternative to free field audiometry test and to examine the relationship between both tests to measure the benefit of individuals from the cochlear implant or hearing aid and evaluate the programming methods. Method: The sample of the study consists of adults with cochlear implant, adults with hearing aid and adults with normal hearing. 80 separate measurements were made, with each group consisting of 20 participants. In the first stage, the free-field hearing thresholds and speech recognition thresholds of all groups were determined by loudspeaker in the silent cabin. In the second stage, tone burst stimulus and /da/ speech stimulus were presented at 500-1000-2000-4000 Hz and the CAEP test was applied. Findings: While there was no statistically significant difference between the free field audiometry test in all groups except the group consisting of individuals with normal hearing (p>0.05), a significant correlation was obtained in all groups, including those with normal hearing (p<0.05). According to the Bland-Altman analysis, it was calculated that there was an agreement between free field audiometry and CAEP measurements in all study groups. Conclusion: Frequency-specific CAEP test is a consistent and highly reliable alternative to evaluate the cochlear implant and hearing aid performance of individuals whose behavioral threshold cannot be determined due to poor cooperation.
Benzer Tezler
- İşitme cihazı ve koklear implant kullanan okul çağı çocuklarında 'İAÜ gürültüde konuşmayı ayırt etme testi' sonuçları
Hearing aid and using cochlear implants in school-age children 'IAU noise speech discrimination test' results
ŞEYDA ŞAHİN
Yüksek Lisans
Türkçe
2021
Kulak Burun ve Boğazİstanbul Aydın ÜniversitesiOdyoloji Ana Bilim Dalı
PROF. DR. BAHRİYE ÖZLEM KONUKSEVEN
- Bimodal koklear implant kullanıcılarında, sinyal işleme zaman senkronizasyonunun gürültüde konuşmayı ayırt etmeye etkisi
The effect of signal processing time synchronization on speech discrimination in noise for bimodal cochlear implant users
ESAT ALKAYA
Yüksek Lisans
Türkçe
2022
Sağlık Eğitimiİstanbul Gelişim ÜniversitesiOdyoloji Ana Bilim Dalı
DR. ÖĞR. ÜYESİ NEBİ MUSTAFA GÜMÜŞ
- Koklear implant kullanıcılarında kulak arkasına takılan ve takılmayan konuşma işlemcilerinin konuşmayı anlama performansı üzerine etkisi
The effects on speech understanding performance of behind the ear and off the ear speech processors in cochlear implant users
MERVE BAYRİ
Yüksek Lisans
Türkçe
2018
Kulak Burun ve BoğazMarmara ÜniversitesiKulak Burun Boğaz Ana Bilim Dalı
DOÇ. DR. AYŞE AYÇA ÇİPRUT
- İşitme cihazı ve koklear implant kullanıcılarında beden algısı
Body i̇mage of hearing aid and cochlear i̇mplant users
SEDA ÖZTÜRK
Yüksek Lisans
Türkçe
2017
Kulak Burun ve BoğazMarmara ÜniversitesiOdyoloji ve Konuşma Bozuklukları Bilim Dalı
DOÇ. DR. AYŞE AYÇA ÇİPRUT
- İşitme cihazı ve koklear implant kullanıcılarında benlik saygısının değerlendirilmesi
Assessment of self-esteem in hearing aid and cochlear implant users
SEMA SATICI
Yüksek Lisans
Türkçe
2019
Kulak Burun ve BoğazMarmara ÜniversitesiKulak Burun Boğaz Hastalıkları Ana Bilim Dalı
DOÇ. DR. EMİNE UFUK DERİNSU