Geri Dön

Koklear implant kullanıcılarında kulak arkasına takılan ve takılmayan konuşma işlemcilerinin konuşmayı anlama performansı üzerine etkisi

The effects on speech understanding performance of behind the ear and off the ear speech processors in cochlear implant users

  1. Tez No: 506950
  2. Yazar: MERVE BAYRİ
  3. Danışmanlar: DOÇ. DR. AYŞE AYÇA ÇİPRUT
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kulak Burun ve Boğaz, Otorhinolaryngology (Ear-Nose-Throat)
  6. Anahtar Kelimeler: Koklear İmplant, Konuşmayı Anlama, Türkçe Matriks Test, Nucleus 6, Kanso, Koklea hastalıkları, Koklear implantlar, Kulak hastalıkları, İşitme, İşitme algısı, İşitme cihazları, Cochlear Implant, Speech Perception, Turkish Matrix Test, Nucleus 6, Kanso, Cochlear diseases, Cochlear implants, Ear diseases, Hearing, Auditory perception, Hearing aids
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kulak Burun Boğaz Ana Bilim Dalı
  12. Bilim Dalı: Odyoloji Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Çalışmamızın amacı, kulak arkasına takılan ve takılmayan konuşma işlemcisi kullanan yetişkin koklear implant kullanıcılarında sessizlikte ve gürültüde konuşmayı anlama performanslarını karşılaştırmaktır. Materyal ve Metot: Kulak arkasına takılan (Nucleus 6) veya takılmayan (Kanso) konuşma işlemcisi kullanan, yaş aralığı 16-70 arasında değişen 27 koklear implant kullanıcısı çalışmamıza dahil edilmiştir. Katılımcıların her iki işlemciyle serbest alanda 5 Hz modülasyonlu uyaranlar kullanılarak cihazlı işitme eşikleri tespit edilmiş ve daha sonra sessiz ortamda konuşmayı ayırt etme skorları elde edilmiştir. Türkçe Matriks Test (TMT), beş farklı hoparlör yerleşiminde gürültüde konuşmayı anlama performansını değerlendirmek için kullanılmıştır. Her iki konuşma işlemcisiyle elde edilen sonuçlar karşılaştırılmıştır. Sonuçlar: Nucleus 6 konuşma işlemcisiyle serbest alanda elde edilen cihazlı işitme eşikleri Kanso konuşma işlemcisiyle karşılaştırıldığında daha iyi bulunmuştur. Ortalama farklılık 3.3 dB HL'dir. Sessiz ortamda yapılan konuşmayı ayırt etme skorları arasında istatistiksel olarak anlamlı bir farklılık bulunmamıştır (p>0,05). TMT'de beş farklı koşulda konuşmayı anlama performansları arasında istatistiksel olarak farklılık elde edilmemiştir (p>0,05). Tartışma: Nucleus 6 ve Kanso konuşma işlemcilerinin mikrofon pozisyonları farklı olmasına rağmen sessizlikte ve gürültüde konuşmayı anlama performansları benzer şekilde elde edilmiştir. Bu sonuçlar yetişkin Kanso kullanıcılarıyla ilgili yapılan önceki çalışmayla uyumlu bulunmuştur.

Özet (Çeviri)

Objective: The aim of the study was to compare speech understanding in quite and in noise in adult cochlear implant recipients using behind the ear and off the ear speech processors. Materials and Method: Twenty-seven cochlear implant recipients between 16-70 years of age using behind the ear or off the ear sound processor were included in the study. Participants were tested with both speech processors in the free field with warble tones and then speech discrimination scores in quiet were obtained. Turkish Matrix test was used to measure speech understanding in noise with five different loudspeaker settings. The results obtained with two speech processors were compared. Results: Aided free field thresholds were significiantly lower/better for Nucleus 6 vs Kanso. Mean difference was 3.3 dB HL. There was no significant difference in speech discrimination scores in quite between Nucleus 6 and Kanso (p>0,05). We did not obtain statistically significant differences of the speech intelligibility in five spatial settings in Turkish Matrix test (p>0,05). Discussion: Although Nucleus 6 and Kanso speech processors had different microphone locations the outcomes were found to be consistent with previous results in adult Kanso users, demonstrating equivalent speech understanding in quiet and in noise.

Benzer Tezler

  1. Kulak arkasına takılan ve kulak arkasına takılmayan, adölesan grubu koklear implant kullanıcılarının cihaz memnuniyet durumunun ve yaşam kalitelerinin değerlendirilmesi

    Evaluation of device satisfaction and quality of life of adolescent group cochlear implant users wearing behind the EAR and not behind the EAR

    MUKADDER TAFLI

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Kulak Burun ve BoğazKapadokya Üniversitesi

    Odyoloji Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MEHMET CELALETTİN CİHAN

  2. Yetişkin koklear implant (Biyonik kulak) kullanıcılarında sinyal gürültü oranının işitsel kortikal yanıtlara etkisinin araştırılması

    Adults cochlear implant (Bionic ear) users, effect on signal to noise ratio in investigation of the auditory cortical responses

    HALİDE ÇETİN KARA

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    Kulak Burun ve Boğazİstanbul Üniversitesi

    Odyoloji Ana Bilim Dalı

    PROF. DR. AHMET ATAŞ

  3. İç kulak anomalisi olan koklear implant kullanıcılarında objektif test yöntemlerinin karşılaştırılması

    Evaluation of objective test techniques in cochlear implant users with inner ear malformations

    BETÜL ÇİÇEK ÇINAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2009

    Kulak Burun ve BoğazHacettepe Üniversitesi

    Kulak Burun Boğaz Ana Bilim Dalı

    DOÇ. DR. AHMET ATAŞ

  4. İç kulak anomalisi olan koklear implant kullanıcılarında koklear implant sonuçları

    The results of cochlear implantation in the inner ear malformations

    ELVAN ONAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2015

    Kulak Burun ve BoğazÇukurova Üniversitesi

    Kulak Burun Boğaz Ana Bilim Dalı

    PROF. DR. ÜLKÜ TUNCER

  5. İç kulak anomalisi olan pediatrik koklear implant kullanıcılarında duyusal işlemlemenin değerlendirilmesi

    Evaluation of sensory processing in pediatric cochlear implant users with inner ear malformation

    MERVE ÖZBAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    Kulak Burun ve BoğazHacettepe Üniversitesi

    Odyoloji ve Konuşma Bozuklukları Ana Bilim Dalı

    DOÇ. DR. SONGÜL AKSOY