Geri Dön

Kıkırdak greft ile onarılmış timpan zarın absorbans özelliklerinin incelenmesi

Investigation of absorbance characteristics of tympanic membranes repaired with cartilage graft

  1. Tez No: 642799
  2. Yazar: BEYZA ASTA
  3. Danışmanlar: DOÇ. DR. KAZIM BOZDEMİR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kulak Burun ve Boğaz, Otorhinolaryngology (Ear-Nose-Throat)
  6. Anahtar Kelimeler: Absorbans, Geniş Bant Timpanometri, Kıkırdak Greft, Kronik Otitis Media, Timpanoplasti, Akustik impedans testleri, Kulak hastalıkları, Kıkırdak, Otitis media, Timpanik membran, Transplantlar, Absorbance, Cartilage Graft, Chronic Otitis Media, Tympanoplasty, Wideband Tympanometry, Absorbans, Acoustic impedance tests, Ear diseases, Cartilage, Otitis media, Tympanic membrane, Transplants
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: Ankara Yıldırım Beyazıt Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Odyoloji ve Konuşma Bozuklukları Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı, kıkırdak greft ile onarılmış TM'nın preop, postop 1. ve 3. ayda absorbans bulgularını GBT ile değerlendirmek ve elde edilen absorbans değerlerini kendi aralarında ve kontrol grubu ile karşılaştırmaktır. Prospektif olarak tasarlanan bu çalışmaya inaktif KOM tanısı almış Tip 1 timpanoplasti yapılması planlanan 20 birey ve herhangi bir kulak patolojisi olmayan 20 sağlıklı birey olmak üzere 40 birey dahil edilmiştir. Kontrol grubuna 1 kez, çalışma grubuna preop, postop 1. ve 3. aylarda olacak şekilde 3 kez saf ses odyometri ve GBT yapılmıştır. Saf ses odyometri sonuçları incelendiğinde, hastaların postop işitme eşiklerinde kayda değer iyileşme olduğu fakat normal değerlere ulaşamadığı görülmüştür. Geniş bant timpanometri sonuçlarına göre postop 3. ayda düşük frekanslarda (226 ile 500 Hz arası) benzer absorbans elde edilirken, orta ve yüksek frekanslarda (2000 ve 8000 Hz hariç) düşük absorbans elde edilmiştir. Hava kemik aralığı ile absorbans değerleri arasındaki ilişkiye bakıldığında, 1000 ve 4000 Hz'de preop ve postop dönemlerde absorbans değerlerinde negatif korelasyon bulunmuştur (p<0.05). Sonuçta, çalışma grubu ile kontrol grubu absorbans değerleri arasında istatistiksel olarak anlamlı farklılık bulunmuştur (p<0.05). Çalışma grubu kıkırdak greft materyali yönünden karşılaştırıldığında istatistiksel olarak anlamlı farklılık gözlenmemiştir. Geniş bant timpanometri, ameliyat sonrası grefte zarar vermeden absorbans bulgularının değerlendirilebilmesinde ve onarılmış TM'nın orta kulak dinamikleri üzerindeki etkilerinin araştırılmasında hızlı ve pratik bir ölçüm aracı olarak yararlı bilgiler sunmaktadır.

Özet (Çeviri)

The purpose of this study is to evaluate the absorbance findings of TM repaired with a cartilage graft, in the pre-op, and the 1st and 3rd months of the post-op through wideband tympanometry and to compare the absorbance values both between themselves and with the control group. In this prospectively-designed study, 40 individuals are included comprising 20 individuals who were diagnosed with COM and planned to undergo Type 1 tympanoplasty and 20 healthy individuals without any ear pathology. Pure tone audiometry was applied once to the control group, and 3 times to the study group (in the pre-op, and the 1st and 3rd months of the post-op.). When PTA results were examined, a significant improvement was observed in the post-op hearing thresholds, despite not reaching normal values. According to the WBT results, in the 3rd month of the post-op, while similar absorbance values were obtained at low frequencies (between 226 and 500 Hz), low absorbance values were obtained at moderate and high frequencies (except for 2000 and 8000 Hz). When the relationship between the air-bone gap (ABG) and the absorbance values was viewed, a negative correlation was found in the absorbance values at 1000 and 4000 Hz in the pre-op as well as post-op (p <0.05). A statistically significant difference was found between the absorbance values of the study and control groups (p <0.05). When a comparison was made in terms of cartilage graft material, in the study group, no statistically significant difference was observed. WBT can evaluate absorbance findings without damaging the graft in the post-op., providing useful information as a quick and practical measurement tool to explore the effects of repaired TM on middle ear dynamics.

Benzer Tezler

  1. Kartilaj ve Perikondrium greftleri kullanılan tip 1 timpanoplasti ameliyatlarında postoperatif saf ses odyometrisi ve absorbsiyon değerlerinin karşılaştırılması

    Comparison of Postoperative Pure Tone Audiometry and Absorption Values in Type 1 Tympanoplasty Surgeries Using Cartilage and Perichondrium Grafts

    NURU ALIYEV

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    Kulak Burun ve BoğazMarmara Üniversitesi

    Kulak Burun Boğaz ve Baş-Boyun Cerrahisi Ana Bilim Dalı

    YRD. DOÇ. DR. YAVUZ GÜNDOĞDU

  2. Artiküler kıkırdak lezyonlarında biyolojik onarım

    Başlık çevirisi yok

    BAYRAM GÜLASAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1991

    Ortopedi ve TravmatolojiOndokuz Mayıs Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

  3. Kıkırdak defektlerinin periost grefti ile onarımı (deneysel çalışma)

    Reconstruction of cartilage defects by periosteal grafts (an experimental study)

    KUTAY ULUTAŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2001

    Plastik ve Rekonstrüktif CerrahiDokuz Eylül Üniversitesi

    Plastik ve Rekonstrüktif Cerrahi Ana Bilim Dalı

    PROF.DR. CAN KARACA

  4. Biyo-sentetik flep prefabrikasyonu ile dairesel trakea defektlerinin onarımı (tavşan modelinde deneysel çalışma)

    Circumferential trachea reconstruction with a prefabricated axtal bio-synthetic flap; experimental study

    AYHAN OKUMUŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2002

    Plastik ve Rekonstrüktif Cerrahiİstanbul Üniversitesi

    Plastik ve Rekonstrüktif Cerrahi Ana Bilim Dalı

    PROF.DR. ORHAN ÇİZMECİ

  5. Tavşanlarda auriküler kıkırdak ile yapılan trakeal rekonstrüksiyonda hiperbarik oksijenin etkisi (deneysel çalışma)

    Effect of hyperbaric oxygen in tracheal reconstruction with auricular cartilage in rabbits

    MURAT SALİ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2002

    Kulak Burun ve BoğazGata

    Kulak Burun Boğaz Ana Bilim Dalı

    DOÇ.DR. ETHEM POYRAZOĞLU