Geri Dön

İmplant simanlarının farklı abutment ve CAD/CAM materyalleri arasındaki bağlantı dayanımı üzerine etkilerinin incelenmesi

Investigation of the effects of implant cements on bond strength between different abutment and CAD/CAM materials

  1. Tez No: 581875
  2. Yazar: NESLİHAN YENİCE
  3. Danışmanlar: YRD. DOÇ. DR. AYŞE KOÇAK BÜYÜKDERE
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: CAD/CAM, Dental implantasyon, Dental implantlar, Dental materyaller, Dental stres analizi, Dental çimentolar, CAD/CAM, Dental implantation, Dental implants, Dental materials, Dental stress analysis, Dental cements
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Kocaeli Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu tez çalışmasının amacı, zirkonya ve titanyum abutmentlar ile farklı CAD/CAM materyallerinin 2 farklı implant simanı ile simantasyonun, makaslama bağlanma dayanımı üzerindeki etkilerinin değerlendirilmesidir. Çalışmada monolitik zirkonya ve titanyum bloklardan her biri 60 adet olacak şekilde (toplam 120) 16x9x2 mm boyutlarında dikdörtgen prizma şeklinde örnekler hazırlandı. Rezin nanoseramik, zirkonyayla desteklenmiş lityum disilikatla güçlendirilmiş seramik (ZLS) ve zirkonyadan oluşan 3 farklı tip CAD/CAM bloğundan 40'ar adet örnek üretildi. Rezin nanoseramik (Lava Ultimate) ve zirkonya (Katana) blokların simantasyon yüzeyi 110 μm partikül büyüklüğüne sahip Al2O3 partikülleri ile kumlandı. Zirkonyayla desteklenmiş lityum disilikatla güçlendirilmiş seramik (Vita Suprinity) yüzeylere ise %9'luk hidroflorik asit uygulaması yapıldı. Üretilen CAD/CAM örnekler, 2 farklı implant simanı (Multilink Speed ve Premier İmplant Simanı) kullanılarak titanyum ve zirkonya örnekler üzerine simante edildi. Simantasyonu takiben örnekler 24 saat boyunca 37 °C'de damıtılmış su içinde depolandı ve sonra universal test cihazında 0,5 mm/dk hızla makaslama testi uygulandı. Elde edilen değerleri Student t-testi, Mann Whitney U, Kruskal Wallis ve All Pairwise testleri kullanılarak istatistiksel olarak değerlendirildi (p<0,05). Tüm Multilink Speed simanlarındaki bağlanma dayanımları [17,15 (±5,75)], Premier İmplant simanlarının bağlanma dayanımlarından [10,66 (±3,85)] anlamlı derecede yüksek bulundu. Titanyum [13,77 (±4,64)] ve zirkonya [14,04 (±6,91)] abutment materyalleri arasında bağlanma dayanımları bakımından anlamlı bir farklılık bulunmadı. Üst yapı seramikleri arasında bağlanma dayanımı bakımından anlamlı bir farklılık vardı (p=0,001). Bu çalışmanın sonuçlarına göre abutment materyal tipinin bağlantı dayanımına etkisinin olmadığı ancak seçilen siman ve üst yapı restorasyonunun bağlantı dayanımı anlamlı olarak etkilediği görülmüştür.

Özet (Çeviri)

The aim of this study is to evaluate the effect of cementation of zirconia and titanium abutments and different CAD / CAM materials with 2 different implant cement on shear bond strength. In this study, each of 60 monolithic zirconia and titanium blocks (total 120) 16x9x2 mm in the form of rectangular prism samples were prepared. 40 samples were produced from 3 different CAD / CAM blocks consisting of resin nanoseramic, zirconia-supported lithium disilicate-reinforced ceramic (ZLS) and zirconia. The cementation surface of the resin nanoceramic (Lava Ultimate) and zirconia (Katana) blocks was blasted with Al2O3 particles having a particle size of 110 μm. Zirconia-reinforced lithium disilicate-reinforced ceramic (Vita Suprinity) surfaces were treated with 9% hydrofluoric acid. The produced CAD/CAM specimens were cemented onto titanium and zirconia specimens using 2 different implant cement (Multilink Speed and Premier Implant Cement). Following cementation, the samples were stored in distilled water at 37 °C for 24 hours, and then shear test was performed on the universal tester at a rate of 0.5 mm/ min. The obtained values were statistically evaluated by using Student t-test, Mann Whitney U, Kruskal Wallis and All Pairwise tests (p <0.05). The binding strengths of all Multilink Speed cements [17,15 (± 5,75)] were found to be significantly higher than those of Premier Implant cements [10,66 (± 3,85)]. There was no significant difference between titanium [13.77 (± 4.64)] and zirconia [14.04 (± 6.91)] abutment materials in terms of bond strength. There was a significant difference in bond strength between the superstructure ceramics (p = 0.001). According to the results of this study, it was observed that abutment material type had no effect on the bond strength, but the selected cement and superstructure restoration significantly affected the bond strength.

Benzer Tezler

  1. The effect of different surface treatments and bonding agent combinations on the shear bond strength of titanium alloy to lithium disilicate glass-ceramics

    Farklı yüzey işlemlerinin ve farklı simanların titanyum tam seramik bağlanma dayanımına etkisi

    AFAF EMHAMED MILAD ALKHADASHI

    Yüksek Lisans

    İngilizce

    İngilizce

    2017

    Diş Hekimliğiİstanbul Yeni Yüzyıl Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. MELAHAT ÇELİK GÜVEN

  2. Farklı dental implant abutment materyallerine değişik simanların bağlanma dayanımının incelenmesi

    Evaluation of the bonding strengths of different cements for different dental implant abutment materials

    BURAK KARAMAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2018

    Diş HekimliğiGaziosmanpaşa Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    YRD. DOÇ. DR. BİLAL HOLOĞLU

  3. İmplant destek preparasyon tasarımı ve yapıştırma simanlarının farklı restorasyon alt yapılarında adezyona etkisinin in vitro olarak incelenmesi

    Evaluation of implant support preparation design and luting cements on different restoration substructures due to adhesion

    ZEYNEP UZGUR

    Doktora

    Türkçe

    Türkçe

    2014

    Diş HekimliğiKırıkkale Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    YRD. DOÇ. DR. NİHAL ÖZCAN

    PROF. DR. SADULLAH ÜÇTAŞLI

  4. Zirkonyum kor yapıların kısa implant dayanakları üzerine simantasyonunda kullanılan farklı yapıştırma simanlarının ve yüzey işleminin tutuculuğa etkisinin incelenmesi

    Effect of different luting cements and surface treatments on the bond strength of zirconia core materials cemented to short implant abutments

    MEHMET MUSTAFA ÖZARSLAN

    Doktora

    Türkçe

    Türkçe

    2010

    Diş HekimliğiSüleyman Demirel Üniversitesi

    Diş Hekimliği Bölümü

    PROF. MUSA ÜSTÜN GÜLDAĞ

  5. Comparative evaluation of casting retention between different fixed prosthesis using the iti solid abutments with seven cements

    Itı solid abutmentler ve yedi siman kullanarak yapılan farklı sabit protezlerde döküm retansiyonunun karşılaştırılmalı değerlendirilmesi

    AİMAN POURAHMARİ

    Yüksek Lisans

    İngilizce

    İngilizce

    2006

    Diş HekimliğiMarmara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. YASEMİN KULAK ÖZKAN