Posterior üç üyeli monolitik zirkonya köprü restorasyonlarının çiğneme simülasyonu sonrası faz dönüşümünün değerlendirilmesi

Evaluation of phase transformation of posterior three-unit monolithic zirconia bridge restorations after chewing simulation

  1. Tez No: 569291
  2. Yazar: GÜLBAHAR ERDİNÇ
  3. Danışmanlar: DOÇ. DR. MEHMET BÜLBÜL
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Benzetim, Dental materyaller, Dental restorasyon, Monolit, Zirkonyum, Çiğneme, Simulation, Dental materials, Dental restoration, Monolith, Zirconium, Mastication
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Eskişehir Osmangazi Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu çalışmanın amacı çiğneme simülasyonunun posterior bölgedeki üç üyeli monolitik zirkonya köprü restorasyonları üzerindeki faz dönüşümlerine etkisini değerlendirmektir. Materyal ve Metot: Üç farklı marka monolitik zirkonya seramiğe ait her gruptan onar tane olmak üzere 30 adet üç üyeli köprü şeklinde örnekler hazırlandı. Bütün örnekler faz dönüşümünü belirlemek için yaşlandırma öncesi ve sonrasında örneklerin konnektörler ve gövde merkezi olmak üzere üç noktasından X-Ray difraksiyon analizine tabi tutuldu. Çiğneme simülasyonu işlemi termal siklus (5-55 oC) ve 240.000 mekanik yükleme (50 N) uygulanarak gerçekleştirildi. XRD verilerindeki pik yoğunlukları kullanılarak göreceli monoklinik faz miktarı değerleri termomekanik siklus öncesi ve sonrası olmak üzere Garvie-Nicholson yöntemi ile hesaplandı. Veriler ANOVA ve Post-hoc testleri ile analiz edildi (p<0.05). Bulgular: X-Ray difraksiyon analizine göre tüm marka ve bölgeler için göreceli monoklinik faz miktarı değerleri yaşlandırma sonrasında yaşlandırma öncesine göre daha yüksek sonuçlar göstermiştir (p<0.05). BruxZir markası gruplar arasında en düşük göreceli monoklinik faz miktarı değerine sahiptir. BruxZir markası hem FireZr hem de Upcera markası ile istatistiksel olarak anlamlı farklılık göstermiştir (p<0.05). FireZr ve Upcera markası arasında anlamlı bir fark görülmemiştir (p˃0.05). Marka gözetmeksizin bölgeler değerlendirildiğinde ve markalar bölgeler açısından kendi içlerinde değerlendirildiğinde konnektör ve gövde arasında istatistiksel olarak anlamlı bir fark görülmemiştir (p˃0.05). Sonuç: Yaşlandırma işlemleri göreceli monoklinik faz miktarında artışa neden olmaktadır. Ancak bu miktar klinik olarak kabul edilebilir düzeydedir. Faz miktarındaki değişimler köprü restorasyonları için konnektör bölgeleri ve gövdeden bağımsızdır.

Özet (Çeviri)

Aim: The aim of this study was to evaluate the effect of chewing simulation on phase transformations of three-unit monolithic zirconia bridge restorations in the posterior region. Material and Method: Thirty three-unit bridges shapes specimens from three different brands of monolithic zirconia ceramics were prepared and divided into three group. All samples were subjected to three-point X-Ray diffraction analysis before and after aging to determine phase transformation, including the connectors and the center of the samples. Chewing simulation was performed by applying thermal cycle (5-55 oC) and 240.000 mechanical loading (50 N). Using the peak intensities in the XRD data, the relative monoclinic phase amount values were calculated by the Garvie-Nicholson method, before and after the thermomechanical cycle. Datas were analyzed by ANOVA and Post-hoc tests (p <0.05). Results: According to X-Ray diffraction analysis, relative monoclinic phase amount values for all brands and regions showed higher results after aging than before aging (p <0.05). BruxZir brand has the lowest relative monoclinic phase quantity value among the groups. BruxZir brand showed a statistically significant difference with both FireZr and Upcera brand (p <0.05). There was no significant difference between FireZr and Upcera brand (p˃0.05). When the regions were evaluated regardless of brand and the brands were evaluated in terms of regions, no statistically significant difference was observed between connector and body. (p˃0.05). Conclusion: Aging processes cause an increase in the relative monoclinic phase amount. However, this amount is clinically acceptable. Variations in the phase quantity are independent of the connector regions and pontic for bridge restorations.

Benzer Tezler

  1. CAD-CAM sistemi ile üretilen implant üstü köprü restorasyonlarda bükülme ve kırılma dayanımına konnektör tasarımının etkisi

    The effect of connector design on flexural and fracturestrength in implant-supported bridge restorationsmanufactured with CAd-CAM system

    BESTE ÇETİN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiGaziantep Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. ÖZGE PARLAR ÖZ

  2. Bilgisayar ile tasarlanarak üretilen translüsent monolitik zirkonya ve çift tabakalı zirkonya restorasyonların klinik başarılarının değerlendirilmesi

    Clinical evaluation of CAD-CAM made translucent monolithic restorations and double-layered restorations

    FİRUZAN TAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2016

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. MUHARREM ERHAN ÇÖMLEKOĞLU

  3. Bruksizmi olan hastalarda implant üstü sabit protezler için farklı üst yapı materyalleri ve implant sayısının implant ve çevre dokuda oluşturduğu stresin sonlu elemanlar analizi yöntemi ile değerlendirilmesi

    Evaluation of stress caused by different superstructure materials and number of implants for implant-supported fixed prosthesis in patients with bruxism by finite element analysis method

    DERYA ASLAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiAtatürk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. NURAN YANIKOĞLU

  4. Zirkonya kalınlığının dual polimerize simanların polimerizasyon derecesi üzerine etkisinin değerlendirilmesi

    Evaluation of zirconia thickness on the degree of conversion of dual-cure resin cements

    BANU ÇUKURLUÖZ BAYINDIR

    Doktora

    Türkçe

    Türkçe

    2014

    Diş HekimliğiGazi Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. SEÇİL KARAKOCA NEMLİ

  5. Kısa ve ekstra kısa dental implant destekli kantilever ve pontik dizaynına sahip sabit protezlerin farklı altyapı materyallerine göre sonlu elemanlar stres analizi ile incelenmesi

    Finite element analysis of stress on short and extra short dental implant supported fixed prosthesis with cantilever and pontic design according to different superstructure materials

    NURCAN KAYA

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiKocaeli Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ SERDAR KILIÇ