Geri Dön

Üniversite yerleşkesinde bulunan binalara ait su depolarının uygunluğu ve içme suyunun mıkrobiyolojik kalitesinin değerlendirilmesi

Adequacy of water depots and drinking water quality used in the university building

  1. Tez No: 569021
  2. Yazar: MEDİNE ÇİÇEK GİRGİN
  3. Danışmanlar: PROF. DR. ALİ CEYLAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Halk Sağlığı, Public Health
  6. Anahtar Kelimeler: Dezenfeksiyon, Dezenfektanlar, Su depolama, Su depoları, Su kalitesi, Üniversite binaları, Üniversite yerleşkeleri, İçme suyu, İçme suyu kirliliği, İçme suyu şebekeleri, Disinfection, Disinfectants, Water storage, Water tanks, Water quality, University buildings, University campuses, Drinking water, Drinking water pollution, Drinking water networks
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Dicle Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Halk Sağlığı Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu çalışmada Dicle Üniversitesi yerleşkesindeki su depolarının giriş ve çıkışlarından bakiye klor ölçümü yapmak, bakteriyolojik su örneği alıp mikrobiyolojik kirlilik düzeyini saptamak, aynı zamanda depoların fiziki durumlarının, periyodik bakımlarını değerlendirmek ve bunu mikrobiyolojik kirliliğe etkisinin saptayarak iyileştirme çalışmalarına katkıda bulunmak amaçlanmıştır. Yöntem: Bu çalışma tanımlayıcı bir çalışmadır. Üniversite yerleşkesindeki 30 binada bulunan 23 depo araştırma kapsamına alınmıştır. Depoların fiziksel özelliklerini değerlendirmek amacı ile Depo Değerlendirme Formu hazırlanarak uygulanmıştır. Depo girişi, depo ile uç noktadaki çıkışlardan (musluk) ve 8 kuyudan bakiye klor ve PH ölçümü yapılmıştır. Devamında ise usulüne uygun bakteriyolojik analiz için steril su numune şişelerine örnek alınmış ve 4,5 mikronluk filtrelerden süzülerek uygun besiyerlerine ekimleri yapılmıştır. Bulgular: Depoların % 36,0'ısı betonarme, % 6,0'sı galvaniz ve % 8,0'i sac/metal yapıdadır. Betonarme depoların % 37,5 inde, Galvaniz depoların % 62,0'sinde, Sac/ metal depoların %50,0'sinde mikroorganizma üremiştir. Depo girişinden alınan 5 numuneden %60'ında Depolardan alınan 23 numuneden %52'sinde depo çıkışından alınan 33 numunenin %57'sinde mikroorganizma üremiştir. 54 numunede tespit edilen 26 farklı mikro organizmalar; Cupriavidus gilardii %82,0, Bacillus cereus, %4,0, Delfita acidovorans %2,0, Stapphylococcus spp. %48,0, Enterobakter spp %8,0, Aeromanas spp %13,0, Acinetobacter baumanni %2,0, Klebsiella pneumoniae %2,0, Enterococcus spp %4,0, Pseudomonas stutzeri %4,0, Rhizobium Radiobacter %2,0, E. Coli %12,0 dir. Sonuç ve öneriler: Üniversite yerleşkesinde bulunan su depoları 'İnsani Tüketim Amaçlı Sular Hakkındaki yönetmelik'' ve diğer ilgi mevzuat hükümlerine uygun olmadığı, periyodik olarak temizlenmediği ve su analizlerinin yapılmadığı görülmüştür. Suyun temin edildiği kuyularda mikro organizma ürediğinden su koruma önlemlerinin ivedilikle alınması, su analizlerinin mevzuata uygun şekilde yapılması gerekmektedir. Su depolarının düzenli olarak temizlenmesi, dezenfekte edilmesi, güvenli içme ve kullanma suyu temininde en önemli basamaklardan birisidir. Anahtar Kelimeler; İçme Suyu Şebekesi, Bakteriyolojik Kirlilik, Su Depoları, Su Dezenfeksiyonu.

Özet (Çeviri)

Aim: In this study, it is aimed to measure the balance chlorine from the inputs and outputs of water tanks in Dicle University campus, to take bacteriological water samples and to determine the microbiological pollution level, at the same time to evaluate the physical conditions and periodic maintenance of the water tanks and to contribute to the improvement studies by determining the effect of this Material and Method: This work is a defining work. 23 warehouses located in 30 buildings in the university campus are covered by research. In order to evaluate the physical properties of the warehouses, The Warehouse evaluation form was prepared and applied. The balance chlorine and PH measurement was made from the tank entrance, the outlet (tap) at the end point with the tank, and the 8 wells. Afterwards, sterile water sample bottles were sampled for the appropriate Bacteriological Analysis and they were filtered through 4.5 micron filters and planted into the appropriate media. Results: Of the warehouses, 36.0% are reinforced concrete, 6.0% are galvanised and 8.0% are of sheet/metal construction. Microorganisms were produced in 37.5% of reinforced concrete stores, 62.0% of galvanised stores, and 50.0% of sheet/ metal stores. Of the 5 samples taken from the warehouse entrance, 60% of the 23 samples taken from the warehouses, 52% of the 33 samples taken from the warehouse exit produced microorganisms in 57%. 26 different micro-organisms detected in 54 samples; Cupriavidus gilardii %82,0, Bacillus cereus, %4,0, Delfita acidovorans %2,0, Stapphylococcus spp. %48,0, Enterobakter spp %8,0, Aeromanas spp %13,0, Acinetobacter baumanni %2,0, Klebsiella pneumoniae %2,0, Enterococcus spp %4,0, Pseudomonas stutzeri %4,0, Rhizobium Radiobacter %2,0, E. Coli %12,0. Conclusions and recommendations: The water tanks in the campus were found to be not in compliance with the provisions of the ' regulation on Waters for human consumption' and other relevant legislation, were not cleaned periodically and water analyses were not carried out. Since micro-organisms are produced in Wells where water is supplied, water protection measures must be taken immediately and water analyses must be carried out in accordance with the legislation. Regular cleaning, disinfecting, safe drinking and using water supply is one of the most important steps. Project Title; Adequacy of Water Depots and Drinking Water Quality Used in the University Building

Benzer Tezler

  1. Yağmur suyu yönetim uygulamalarının değerlendirilmesi Dokuz Eylül Üniversitesi Tınaztepe yerleşkesi örneği

    Evaluation of the rainwater management practices: Dokuz Eylul University Tınaztepe Campus case study

    EKİN ÇAĞLAR GÖKBAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ALPASLAN EKDAL

  2. Sakarya Üniversitesi kampüs bölgesinde bina içi radon konsantrasyonunun belirlenmesi

    Determination of radon concentration in building in Sakarya University campus region

    KÜBRA GÜNERMELİKOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Fizik ve Fizik MühendisliğiSakarya Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. FİLİZ ERTUĞRAL YAMAÇ

  3. Enerji verimliliği bakımından Bitlis Eren Üniversitesi kampüs binalarının enerji etüdü

    In terms of energy efficiency energy audit for campus buildings of Bitlis Eren University

    ALİ ELHUVEYDİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Makine MühendisliğiBitlis Eren Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ FARUK ORAL

  4. Seismic monitoring of ITU Triga Mark II research reactor building

    İTÜ Triga Mark II araştırma reaktörü binasının sismik yöntemler ile izlenmesi

    ŞİNASİ MERT ÇAKMAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2017

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    Jeofizik Mühendisliği Ana Bilim Dalı

    PROF. DR. AYŞE KAŞLILAR ŞİŞMAN

  5. Jeotermal kaynaklı ısı pompasının mevcut hidronik sistemlere entegresi

    Integrating the geothermal heat pumps existing hydronic systems

    MUSTAFA TOLGA BALTA

    Yüksek Lisans

    Türkçe

    Türkçe

    2005

    Makine MühendisliğiNiğde Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Y.DOÇ.DR. DOĞAN DEMİRAL