Geri Dön

Mini-implant uygulamalarında farklı maksillar uzunluğa sahip bireylerin palatinal bölgelerindeki kemik miktarının üç boyutlu değerlendirmesi

Three-dimensional evaluation of bone thickness in palatinal regions for mini screw applications at individuals with different maxillary length

  1. Tez No: 548989
  2. Yazar: HASAN TELLİ
  3. Danışmanlar: PROF. DR. ABDULVAHİT ERDEM
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Mini vida uygulaması, Palatinal bölge, Konik ışınlı bilgisayarlı tomografi, Dolphin yazılım programı, Bilgisayar yazılımları, Kemik ve kemikler, Kemik vidaları, Maksilla, Ortodonti, Radyografi-dental, Mini screw application, Palatinal zone, Dolphin 3D software, Cone-beam tomography Keywords: Mini screw application, Conebeam computed tomography, Computer softwares, Bone and bones, Bone screws, Cone-beam computed tomography, Maxilla, Orthodontics, Radiography-dental
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Atatürk Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Mini-İmplant Uygulamalarında Farklı Maksillar Uzunluğa Sahip Bireylerin Palatinal Bölgelerindeki Kemik Miktarının Üç Boyutlu Değerlendirilmesi Amaç: Bu çalışmanın amacı; Konik Işınlı Bilgisayarlı Tomografi (KIBT) görüntülerini kullanarak, palatinal üçüncü ruga bölgesindeki kemik kalınlıklarını değerlendirmek ve bu bölgeye uygun mini vida uzunluğunu belirlemektir. Materyal ve Metot: Araştırmamızda, tanı amacıyla alınmış KIBT görüntülerinde, maksillanın anteroposterior yöndeki uzunluğuna göre iki gruba ayrılan bireylerde(kısa maksilla grubu ve normal maksilla grubu) palatinal üçüncü ruga bölgesindeki kemik kalınlıkları ölçülmüştür.Yapılan ölçümler Dolphin 3D yazılımı kullanılarak değerlendirilmiştir. Elde edilen veriler SPSS 20.0 programı kullanılarak istatistiksel değerlendirmeye tabi tutulmuştur. Bulgular:İki gruptaki bireyler arasında, vertikal, oblik ve horizontal olarak yapılan kemik kalınlığı ölçümlerinde istatiksel olarak anlamlı bir farklılık görülmemiştir. (p>0.05). Sonuç: Çalışmamızın sonuçları kısa ve normal maksilla gruplarında damaktaki üçüncü ruga bölgelesinde kemik kalınlıklarının benzer olduğu ve bu bölgeye 6 mm boyundaki mini vidanın güvenle uygulanabileceğini göstermiştir.

Özet (Çeviri)

Three-Dimensional Evaluation of Bone Thickness in Palatinal Regions for Mini Screw Applications at Individuals with Different Maxillary Length Objective: The aims of this study was; to evaluate bone thickness of palatal third ruga region using the cone beam computed tomography (KIBT) images and to determine suitable mini screw length for the application in this region. Materials and Method: In this study, bone thickness in the palatal third ruga region was measured in two group individuals (short maxilla group, normal maxilla group) by using KIBT images which taken for diagnostic purposes. Measurements were done on cone beam computed tomography images by using Dolphin 3D ( 11.9 version) software. The data were statistically analyzed using the SPSS 20.0 program.Inter-group comparisons were done by using Independent Samples t test. Results: There was no statistically significant difference was found between the two groups in terms of vertical, oblique and horizontal bone thickness measurements. Conclusion: Our results indicated that individuals with short and normal maxilla have similar bone thickness in palatal third ruga region and the mini-screws in 6 mm length can be applied safely in this region.

Benzer Tezler

  1. Assessment of hard tıssue densıty around dental ımplants usıng conventıonal radıographs

    Dental implantlar çevresindeki sert doku densitesinin konvensiyonel radyograflar ile incelenmesi

    WAEL ALSHAIBANI

    Doktora

    İngilizce

    İngilizce

    2010

    Diş HekimliğiGazi Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. NUR MOLLAOĞLU

  2. Miniplakların ağız içine cerrahi yönteme başvurulmadan yerleştirilmesi için geliştirilen yeni bir uygulama: 3-boyutlu sonlu elemanlar stres analizi ile uygulamanın etkinliğinin değerlendirilmesi

    New method for the placement of miniplates in mouth without surgical applications: Evaluation of the application with 3-dimensional finite element stress analysis

    VOLKAN AYKAÇ

    Doktora

    Türkçe

    Türkçe

    2013

    Diş HekimliğiGazi Üniversitesi

    Ortodonti Ana Bilim Dalı

    DOÇ. DR. MEHMET ÇAĞRI ULUSOY

  3. 3D printed, cell carrying gelma hydrogels in corneal stroma engineering

    3B basılı hücre taşıyan gelma hidrojelleri ile kornea stroma mühendisliği

    CEMİLE BEKTAŞ

    Doktora

    İngilizce

    İngilizce

    2018

    BiyoteknolojiOrta Doğu Teknik Üniversitesi

    Biyoteknoloji Ana Bilim Dalı

    PROF. DR. VASIF NEJAT HASIRCI

    PROF. DR. AYŞE BURCU

  4. Investigation of the growth kinetics and morphology transitions during porous anodization of titanium in ethylene glycol based electrolytes

    Etilen glikol bazlı elektrolitlerde titanyumun gözenekli anodizasyonu sırasında oluşan oksidin büyüme kinetiği ve morfolojik geçişlerinin incelenmesi

    EREN SEÇKİN

    Doktora

    İngilizce

    İngilizce

    2022

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    Malzeme Bilimi ve Mühendisliği Ana Bilim Dalı

    PROF. DR. MUSTAFA KAMİL ÜRGEN

  5. Hemiartroplasti uygulanan femur boyun kırıklı hastalarda radyografik olarak femoral ofset ve bacak boyu ölçümlerinin karşılaştırılması (Retrospektif çalışma)

    Radiographically comparison of femoral offset and leg length measurements in patients with hemiarthroplasty-applied femoral neck fractures

    CENGİZ KOPUZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2017

    Ortopedi ve Travmatolojiİstanbul Bilim Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DOÇ. DR. NESLİHAN AKSU