Farklı apeks bulucu sistemlerin farklı irrigasyon solüsyonları varlığında kök perforasyonlarını belirlemedeki doğruluğunun değerlendirilmesi
Evaluation of different apex finder systems for determination of root perforations in presence of different i̇rrigation solutions
- Tez No: 547679
- Danışmanlar: DOÇ. UĞUR AYDIN
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Diş apeksi, Kök kanal tedavisi, Kök kanalı irrigantları, İrrigasyon, İrrigasyon-yara, Tooth apex, Root canal therapy, Root canal irrigants, Irrigation, Irrigation-wound
- Yıl: 2019
- Dil: Türkçe
- Üniversite: Gaziantep Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Endodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Geçmişten günümüze elektronik apeks bulucular (EAB) ile ilgili en çok çalışma yapılan konulardan bir tanesi; elektro iletkenlerin EAB'lerin doğruluğuna olan etkisinin araştırılmasıdır. Modern EAB üreticileri, bu yeni cihazların elektro iletkenlerden olumsuz etkilenmediklerini iddia etseler de bu konu tam olarak kesinlik kazanmamıştır. Bu çalışmada 3 farklı modern EAB (Root ZX mini, Raypex 6, Apex ID) kullanıldı; elektro iletken irrigasyon solüsyonların (%5'lik NaOCl, %0,9'luk Sodyum Klorür (NaCl) çözeltisi ve %17'lik EDTA) varlığında ve kuru kanal koşullarındaki doğruluk oranları değerlendirildi. Çalışmada kullanılmak üzere 64 adet insan maksiller 1. molar dişin meziobukkal kökü seçildi ve rezorbsiyona uğramış, kırık ve açık apeksli kökler çalışmaya dahil edilmedi. Çalışmada 25-35 derece eğime sahip olan kökler kullanıldı ve bu eğim oranlarına sahip olmayan kökler de çalışma dışı bırakıldı. Kök kanal içerikleri boşaltılıp kanallar sırasıyla 25 ve 40 numaralı Reciproc (VDW, Münih, Almanya) döner alet eğeleri ile genişletildikten sonra kökler 40 numara boyterlok kullanılarak lateral yüzeylerinden perfore edildi. Perforasyon noktasına kadar olan gerçek uzunlukların ve elektronik uzunlukların belirlenmesi X4 büyütme (Carl Zeiss Gmbh., Jena, Almanya) altında görsel olarak yapıldı. İstatistiksel analizler sonucunda gerçek uzunluklar ile elektronik ölçümler arasında 0,05 düzeyinde anlamlılık dereceleri bulunan gruplar belirtildi. Kuru kanal koşullarında ve Serum Fizyolojik (SF) ile yıkanan kanallarda, Root ZX cihazı ile yapılan elektronik ölçümlerle gerçek uzunluklar arasında 0,05 düzeyinde anlamlılık dereceleri bulundu. Yine %5'lik NaOCl, %0,9'luk Sodyum Klorür (NaCl) çözeltisi (SF) ve %17'lik EDTA ile yıkanan kanallarda, Raypex 6 ve Apex ID cihazı ile yapılan elektronik ölçümlerle gerçek uzunluklar arasında 0,05 düzeyinde anlamlılık dereceleri bulundu.
Özet (Çeviri)
One of the most studied subjects about electronic apex locators (EAL) from past to present; the effect of electroconductors on the accuracy of EALs. Although modern EAL manufacturers claim that these new devices are not adversely affected by electroconductors, this issue has not been fully clarified. Three different modern EAB (Root ZX mini, Raypex 6, Apex ID) were used in this study. In the presence of electroconductive irrigation solutions (5% NaOCl, 0.9% Sodium Chloride (NaCl) solution and 17% EDTA) and in dry canal conditions, the accuracy of EALs were evaluated. The mesiobuccal root of 64 human maxillary 1st molar teeth free of any resorbtion, cracks and open apices were included. Roots with a curve of radius of 25-35 degrees were used in the study and the roots without these slope ratios were also excluded. Root canal contents were evacuated and canals were prepared with Reciproc (VDW, Munich, Germany) instruments. Determination of actual lengths and electronic measurement to the point of perforation were performed visually under X4 magnification (Carl Zeiss GmbH, Jena, Germany). As a result of the statistical analysis, groups between the actual lengths and the electronic measurementswere defined with significance levels of 0.05. In the dry root channel conditions and Serum Physiological (SP) washed channels, the level of significance was found to be 0.05 between the electronic measurements made with the root ZX device. Also, electronic measurements made with Raypex 6 and Apex ID were found to be significant at the 0.05 level in the channels which was washed 5% NaOCl, 0.9% Sodium Chloride (NaCl), solution (SP) and 17% EDTA.
Benzer Tezler
- Farklı irrigasyon solüsyonlarının elektronik apeks bulucu ile tespit edilen elektronik ölçümlere etkilerinin karşılaştırılması
Comparison of the effects of different irrigation solutions on the measurements by electronic apex locator
FATMA BEGÜM PEKER
Diş Hekimliği Uzmanlık
Türkçe
2020
Diş Hekimliğiİstanbul Medipol ÜniversitesiEndodonti Ana Bilim Dalı
DR. ÖĞR. ÜYESİ YELDA ERDEM HEPŞENOĞLU
DR. ÖĞR. ÜYESİ TAN FIRAT EYÜBOĞLU
- Üç farklı elektronik apeks bulucu, radyovizyografi ve konik ışınlı bilgisayarlı tomografinin süt dişi kök kanal tedavisinde çalışma boyu belirlenmesinde doğruluğunun değerlendirilmesi
The accuracy of three different electronic apex locators, radiovisiography and cone-beam computed tomography in determination of the working lenght measurement on primary teeth root canal treatment
MEVLÜT KAYABAŞI
Diş Hekimliği Uzmanlık
Türkçe
2019
Diş HekimliğiSivas Cumhuriyet ÜniversitesiÇocuk Diş Hekimliği Ana Bilim Dalı
DOÇ. DR. FATİH ÖZNURHAN
- Mandibular mesial kanallarda, iki farklı elektronik apeks bulucu doğruluğunun, mikro bilgisayarlı tomografi kullanılarak değerlendirilmesi
Evaluation of TWO different electronic APEX locator accuracy in mandibular mesial canals using micro computed tomography
ZÜBEYDE GÖKÇE TURHAN
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş HekimliğiGazi ÜniversitesiEndodonti Ana Bilim Dalı
PROF. DR. ALİ CEMAL TINAZ
- Farklı elektronik apeks bulucuların kök perforasyonlarının tespitinde etkili olabildikleri minimum perforasyon çapının belirlenmesi
Accuracy of different electronic apex locators in determination of minimum root perforation diameter
SİMAY KOÇ DEVECİ
Diş Hekimliği Uzmanlık
Türkçe
2021
Diş HekimliğiAkdeniz ÜniversitesiEndodonti Ana Bilim Dalı
PROF. DR. ALPER KUŞTARCI
- Farklı intrakanal medikaman uygulamalarının dört farklı apeks bulucunun ölçüm doğruluğuna etkisi
The effect of different intracanal medications on the accuracy of four different apex finders in measurement
HAMZA CUDAL
Diş Hekimliği Uzmanlık
Türkçe
2021
Diş HekimliğiErciyes ÜniversitesiEndodonti Ana Bilim Dalı
DOÇ. DR. TUĞRUL ASLAN