Geri Dön

Ortodontik metal ve seramik braketlerin yapıştırılmasında kullanılan primersiz tek adımlık sistemin mikrosızıntı ve bağlanma dayanımlarının farklı adeziv sistemleri ile in vitro olarak karşılaştırılması

In vitro comparison of microleakage and bond strength of one-step sysyem without primer used in bonding of orthodontic metal and ceramic brackets with different adhesive systems

  1. Tez No: 536837
  2. Yazar: HANDAN BAYAR BİLEN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ SERPİL ÇOKAKOĞLU
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental bonding, Dental sızma, Dental çimentolar, Ortodonti, Ortodonti-düzeltici, Ortodontik aygıtlar, Ortodontik braketler, Dental bonding, Dental leakage, Dental cements, Orthodontics, Orthodontics-corrective, Orthodontic appliances, Orthodontic brackets
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Pamukkale Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Çalışmamızın amacı farklı tip braketlerin yapıştırılmasında kullanılan primersiz tek adımlık adeziv sistemin etkinliğini mikrosızıntı ve bağlanma dayanımı açısından in vitro koşullar altında farklı adeziv sistemler ile karşılaştırmaktır. Çalışmamızda mikrosızıntı ve bağlanma dayanımının değerlendirileceği örnekler metal ve seramik braketlerin uygulandığı 2 ana gruba, ardından da farklı adeziv sistemlerin kullanıldığı 3 alt gruba ayrılarak, 6 grup oluşturulmuştur (n=12). Braket yapıştırılmış tüm dişler termal siklus işlemine tabi tutulmuştur. Mikrosızıntı örneklerine boyama işlemleri uygulanıp, her dişten 2 kesit alınmıştır. Bağlanma dayanımı örneklerine ise sıyırma testleri uygulanıp, bağlanma dayanıklılıkları ölçülmüştür. Mikrosızıntı ve kopma bölgeleri stereomikroskop altında incelenerek, mikrosızıntı ve AAE skorlamaları yapılmıştır. Elde edilen veriler istatistiksel olarak değerlendirilmiştir. Asitlenen-yıkanan ve primersiz tek adımlık sistemlerin mikrosızıntı skorları arasında anlamlı bir fark bulunmamıştır. Ancak kendinden asitli primer gruplarında diğer adeziv sistemlere göre oklüzal yönde anlamlı olarak daha fazla mikrosızıntı izlenmiştir (p<0.05). Farklı braket tiplerinin mikrosızıntı üzerine etkisi olmamıştır. Primersiz tek adımlık sistem ile diğer sistemlerin bağlanma dayanımı değerleri benzerdir. Metal braketler kullanıldığında primersiz tek adımlık sistemin AAE skorları, diğer adezivlerden anlamlı olarak farklı bulunmuştur. Kopma bölgeleri bu grupta daha çok braket-adeziv ara yüzeyinde ve adezivin kendi yapısı içindedir. Seramik braketlerde ise primersiz ve asitlenen-yıkanan sistemlerde AAE skorları benzerdir. Farklı braket tipinin kullanımı sadece asitlenen-yıkanan sistemde anlamlı farklılığa sebep olmuştur (p<0.05). Primersiz tek adımlık GC Ortho Connect yapıştırıcının mikrosızıntı ve bağlanma dayanımı değerleri açısından genel olarak konvansiyonel asitlenen-yıkanan sistemler ile benzerlik gösterdiği ve klinik kullanım için yeterli olduğu söylenebilir.

Özet (Çeviri)

The purpose of this study was to compare the efficacy of the one step adhesive system without primer used for bonding different types of brackets with different adhesive system under in vitro conditions in terms of microleakage and shear bond strength. In this study, the microleakage and shear bond strength samples were divided into 2 groups including metal and ceramic brackets and then divided into 3 subgroups used different adhesive systems and finally 6 groups were formed (n=12). Thermocycling was performed to all teeth. Microleakage samples were applied to dye penetration and two parallel longitudinal sections were taken from each sample. The shear bond strength tests were performed and SBS values were measured. The microleakage and failure sites were assessed with microleakage scores and ARI using a stereomicroscope. Data were analyzed statistically. When microleakage scores were considered, there was no statistical difference between conventional acid-etching system and one step adhesive system without primer. However, in self-acid primer groups, more microleakage was observed in the occlusal direction than the other adhesive systems (p<0.05). Different types of brackets had no effect on microleakage. SBS values of the one-step adhesive system were similar with other adhesive systems. When metal brackets were used, the ARI scores of the one step adhesive system without primer were significantly different than the other groups. In this group, the failure sites were mostly in the bracket-adhesive interface and inside of the adhesive. In ceramic bracket groups, ARI scores of the one step adhesive and acid-etch systems were similar. The use of different types of bracket has lead to a significant difference only acid-etch adhesive group (p<0.05). When the results of this study were considered, one step adhesive system without primer (GC Ortho Connect) was similar to conventional acid-etching adhesive system and was sufficient for clinical use.

Benzer Tezler

  1. Metal ve porselen braketlerin yapıştırılmasında farklı ışık gücü uygulandığında mine yüzeyiyle olan makaslama bağlanma dayanımlarının ve mikrosertliğinin değerlendirilmesi

    Evaluation of the shear bond strength and microhardness with the enamel surface when different light power is applied in the adhesive of metal and porcelain brackets

    CANSU ŞEYMA AĞRILI

    Doktora

    Türkçe

    Türkçe

    2024

    Diş Hekimliğiİstanbul Kent Üniversitesi

    Ortodonti Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MERVE KURNAZ

  2. Yeni ve yaşlandırılmış reçine kompozit yüzeylere yapıştırılan metal ve porselen braketlerin makaslama bağlanma dayanımlarının değerlendirilmesi

    Evaluation of shear bond strength of metal and ceramic brackets bonded to new and aged resin composite surfaces prepared with different surface treatment techniques

    MUHAMMET FURKAN VATAN

    Doktora

    Türkçe

    Türkçe

    2023

    Diş Hekimliğiİstanbul Üniversitesi

    Ortodonti Ana Bilim Dalı

    DOÇ. DR. SÜLEYMAN EVREN ÖZTAŞ

  3. Rezinle güçlendirilmiş bir cam-iyonomer simanın in vitro ve in vivo olarak araştırılması

    In vitro and in vivo evaluation of a resin reinforced glassionomer cement

    METE ÖZER

    Doktora

    Türkçe

    Türkçe

    1998

    Diş HekimliğiOndokuz Mayıs Üniversitesi

    Ortodonti Ana Bilim Dalı

    YRD. DOÇ. DR. SELİM ARICI

  4. Metal ve seramik braketlerin hibrit seramik CAD-CAM materyali üzerinde yapılan farklı yüzey pürüzlendirmelerinde makaslama dirençlerinin değerlendirilmesi

    Evaluation of shear bond strength of metal and ceramic brackets on different surface roughenings on hybrid ceramic CAD-CAMmaterial

    ÖZGÜR DEMİR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2018

    Diş HekimliğiDicle Üniversitesi

    Ortodonti Ana Bilim Dalı

    DOÇ. GÜVENÇ BAŞARAN

  5. Metal ve farklı tip seramik braketlerin sökümü sonucu mine yüzeyinde oluşan hasarın in vitro incelenmesi

    The investigation of the damage that occurs on enamel surface as a result of the removal of metal and different type ceramic brackets: An in vitro study

    HASAN GÜNDAL

    Doktora

    Türkçe

    Türkçe

    2021

    Diş HekimliğiBaşkent Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. BURÇAK KAYA