Geri Dön

Plaka üzeri boru tipi buharlaştırıcı boru çapı değişikliğinin soğutma sistem performansı üzerine etkisinin deneysel çalışması

The experimental study of different plate on tube type evaporator diameters effect on the cooling system performance

  1. Tez No: 519581
  2. Yazar: TAYFUN ERSÖZ
  3. Danışmanlar: DOÇ. DR. NİHAL UĞURLUBİLEK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Buharlaştırarak soğutma, Evaporative cooling
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Eskişehir Osmangazi Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Enerji Termodinamik Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Soğutucu akışkanın soğutulmak istenen ortamdan ısı çekmesini sağlayan buharlaştırıcı, soğutma sisteminde bulunan en önemli komponenttir. Enerji verimli ürünlerin önemli olduğu bir dönemde sistemin performansını en çok etkileyen komponent olan buharlaştırıcı üzerine çalışmalar yapılmaktadır. Bu çalışma, ev tipi buzdolaplarındaki soğutma sistemi elemanlarından olan buharlaştırıcının performansının optimize edilmesi ve enerji tüketiminin azaltılması için boru çapının ve buharlaştırıcı performansını etkileyen kapileri boru uzunluğu ve gaz şarjının deneysel olarak geliştirilmesi amacıyla hazırlanmıştır. Çalışma sadece bir model üzerinde yapılmış olmakla beraber diğer tüm ürünlere yaygınlaştırılarak kullanılabilecektir. Yapılan optimizasyon çalışması ile enerji tüketiminde meydana gelecek iyileşme, ürün gamının düşük enerjili ürünlerle genişletilmesinde faydalı olacaktır. Sonuç olarak, ev tipi buzdolabında karşılaştırılan parametreler arasında buharlaştırıcı performansını etkileyen en önemli parametrelerin gaz şarjı ve boru çapı olduğu belirlenmiştir. En düşük enerji tüketimini veren 6 mm boru ve 16 gr gaz şarjı miktarı olduğu tespit edilmiştir. Mevcut 7 mm boru ve 18 gr gaz şarjından 6 mm boru ve 16 gr gaz şarjı kullanılan sisteme geçildiğinde buzdolabının enerji tüketiminde %16,6 iyileşme sağlandığı görülmüştür. Çalışmada kullanılan buharlaştırıcının bir ürüne uygulanarak seri üretime geçilmesi ve diğer ürünlere de yaygınlaştırılarak kullanılması planlanmaktadır.

Özet (Çeviri)

The evaporator, which enables the refrigerant to draw heat from the desired environment, is the most important component in the refrigeration system. In a period when energy efficient products are important, studies are being made on the evaporator which is the component that effects the performance of the system most. This study was designed to optimize the performance of the evaporator from the refrigeration system components in domestic refrigerators and to experimentally improve the capillary tube length and gas charge effecting pipe diameter and evaporator performance to reduce energy consumption. The study can be used only on one model and spread to all other products. With the optimization work done, the improvement in energy consumption will be beneficial in expanding the product range with low-energy products. As a result, it has been determined that the most important parameters effecting the evaporator performance among the comparative parameters in the domestic refrigerator are gas charge and pipe diameter. It has been determined that the minimum energy consumption is 6 mm pipe and 16 gr gas charge amount. It has been observed that the energy consumption of the refrigerator has improved by 16,6 % when the existing 7 mm pipe and 18 gr gas charge to 6 mm pipe and 16 gr gas charge system are used. The evaporator used in the study is planned to be applied to a product and to be used in series production and spreading to other products.

Benzer Tezler

  1. Hastanelerde acil servis hizmetleri

    Başlık çevirisi yok

    CİHAN SEVİM

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    HastanelerGazi Üniversitesi

    Kazaların Çevresel ve Teknik Araştırması Ana Bilim Dalı (disiplinlerarası)

    DOÇ. DR. MEHMET ALİ BUMİN

  2. Çekirdeksiz kuru üzümlerde aflatoksin B1, B2, G1, G2 tayini için mevcut bazı metotların karşılaştırılması üzerinde bir çalışma

    Başlık çevirisi yok

    DİLEK BOYACIOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gıda MühendisliğiEge Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. MERAL GÖNÜL

  3. Femur boyun bölgesi kırıklarının kompresyonlu ve kayıcı kalça çivileri ile tedavisi

    Başlık çevirisi yok

    OSMAN UĞUR ÇALPUR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1985

    Ortopedi ve Travmatolojiİstanbul Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF. DR. FAHRİ SEYHAN

  4. Mimari çevrede değişme sürecinin analizi Ulus-Çankaya aksi (Ankara) üzerinde bir deneme

    Başlık çevirisi yok

    MUSTAFA KANDİL

    Doktora

    Türkçe

    Türkçe

    1987

    MimarlıkKaradeniz Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    DOÇ.DR. D. ZAFER ERTÜRK