Geri Dön

Prepatrion of the patentiometric immobilizied urease electrode anf urea determination

Başlık çevirisi mevcut değil.

  1. Tez No: 50825
  2. Yazar: AHMET ŞEHİTOĞULLARI
  3. Danışmanlar: PROF.DR. ARİF H. USLAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyomühendislik, Bioengineering
  6. Anahtar Kelimeler: Üreaz, Üre Tayini, Enzim Elektrodu, Biyosensörler, Üre, Urease, Urea Determination, Enzyme Electrodes, Biosensors, Urea
  7. Yıl: 1996
  8. Dil: İngilizce
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Belirtilmemiş.
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

11 ÖZET POTANSÎYOMETRÎK ESASLI IMMOBÎLÎZE UREAZ ELEKTRODU HAZIRLANMASI VE ÜRE TAYÎNÎ ŞEHlTO?ULLARI, Ahmet Yüksek Lisans Tezi, Biyokimya Bölümü Tez Yöneticisi : Prof.Dr. Arif H.USLAN Kasım 1996, 47 sayfa Bu tezde, PVA(polyvinilalkol), FMP(2-Floro-l-metilpiridinium tolien-4-sülfonat) ile aktifleştirilmiş ve üreaz (EC 3.5.1.5) kovalent olarak bağlanmıştır. PVA-Üreaz gluteraldehit yardımıyla jelatin ile çapraz bağlanarak bir pH cam elektrodu üzerinde immobilize edilerek üreye duyarlı bir enzim elektrodu geliştirilmiştir. Ölçümler enzimatik reaksiyon uyarınca, üre konsantrasyonuyla orantılı olarak değişen ortam potansiyelinin belirlenmesi yoluyla ve çizilen standart grafikler yardımıyla yapılmıştır. Hazırlanan biyosensörün optimiasyon çalışmalarında en uygun üreaz, jelatin ve gluteraldehit miktarları sırasıyla, 8 mg/ml, 54 mg/ml ve 0.5% ile 5.0 dak. olarak bulundu. Optimum çalışma ortamı olarak 10 mM'lık pH:8.0 olan fosfat tamponunun kullanılması ve ölçümlerin 25°C yapılması gerektiği sonucuna varıldı. Geliştirilen biyosensörün karakterizasyonu amacıyla yapılan çalışmalar sonucunda 8.9xl0~5-l"lxl0~3 M üre konsantrasyon aralığında doğrusal sonuçların alınabildiği tesbit edildi. Ayrıca tampon konsantrasyonunu, 10 mM-100 mM arasında değiştirerek 10-2-10-5 yi jjre konsantrasyonu aralığında çalışılabileceği tesbit edildi. Tekrarlanabilirlik denemesi (n=20), aynı bir serum örneği için üreaz enzim elektrodu ve fotometrik metod ile yapılmıştır. Her iki metod için sırasıyla ortalama değerler (X)ı=5.96 mM ve (X)2=5.86 mM, standart sapmalar (S.S)ı=±0.149 ve (S.S)2=±0.206, varyasyon katsayıları (V.K)ı=%2.5 ve (V.K)2=%3.51 olarak bulunmuştur. Bu sonuçlara göre üreaz enzim elektrodunun daha hassas ve duyarlı olduğu görülmektedir. Elektrod için depo kararlılığı araştırılmıştır.

Özet (Çeviri)

İÜ ABSTRACT PREPARATION OF THE POTENTIOMETRIC IMMOBILIZED UREASE ELECTRODE AND UREA DETERMINATION ŞEHÎTO?ULLARI, Ahmet MSc in Biochemistry Supervisor : Prof.Dr. Arif H.USLAN November 1996, 47 page In this thesis, PVA (polyvinylalcohol) was activated with FMP (2-Fluoro-l-methylpyridiumtoluene-4-sulphonate) and urease (EC.3.5.1.5) was linked to the activated substance covalently. PVA-Urease was cross-linked with gelatine by using gluteraldehyde and was immobilized on a surface of pH-glass electrode, therefore, enzyme electrode which was sensitive for urea was developed. Measurements were carriede out by standard curves which were determined by the changing medium potential related to urea concentration in the enzymatic reaction. In the optimization studies of biosensors prepared, the most suitable urease, gelatine and gluteraldehyde amounts were determined as 8 mg/ml, 54 mg/ml and for 5 min. 0.5 % respectively. The phosphate buffer (pH:8.0, 10 mM) and 25°C were established as providing the optimum conditions. The characterization of the developed biosensor studies proved a linearity in the urea concentration range 8.9x10“^- 1.1x10”3 M. Also, by changing the buffer concentration (10 mM-100 mM range), it was stablied that can be studied at the urea concentration range of 10“^-10”5 M. Reproducibilty experiments (n=20) were done with urease enzyme electrode and photometric method for the same serum sample. Average valves [(X)ı,(X)2İ for each two methods were 5.96 mM and 5.86 mM, standard deviations [(S.D)j,(S.D)2] were ± 0.149 and ±0.206 and variation coefficients [(C.V)i,(C.V)2] were 2.50% and 3.51%, respectively. According to these results, it was observed that urease electrode was more sensitive. Storage stability were investigated for the urease enzyme electrode.

Benzer Tezler

  1. Ethyle alfa-hydroxymethylacrylate: functionalization, Homo and copolymerizatrion and prepation of wood polymer composites

    Başlık çevirisi yok

    DUYGU AVCI

    Doktora

    İngilizce

    İngilizce

    1993

    KimyaBoğaziçi Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. SELİM KÜFEOĞLU

  2. Ferritik-ostenitik paslanmaz çelik çiftinin nokta kaynağında kaynak parametrelerinin çekme-makaslama mukavemetine ve tanelerarası korozyona etkisi

    The effect of welding parameters to the tensile-shear strength and intercrystalline corrosion in the spot welding of ferritic-austenitic stainless stell

    ERDİNÇ KALUÇ

    Doktora

    Türkçe

    Türkçe

    1988

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    PROF. SELAHADDİN ANIK

  3. Tetratiya-makrohalkaları içeren yeni tip ftalosiyaninler

    Başlık çevirisi yok

    AYŞE GÜL GÜREK

    Doktora

    Türkçe

    Türkçe

    1996

    Kimyaİstanbul Teknik Üniversitesi

    PROF.DR. BEKAROĞLU ÖZER

  4. PCR based, isolation, cloning on expression of streptokinase gene from a group c streptococcus equisimilis in e.coli

    Bir grup c (Streptocossus equisimilis)'e ait olan streptokinaz genin pcr-aracılığı ile izolasyonu, klonlaması ve e.coli'de ifade edilmesi

    FARZİN ROOHVAND

    Doktora

    İngilizce

    İngilizce

    1998

    BiyoteknolojiOrta Doğu Teknik Üniversitesi

    Biyoteknoloji Ana Bilim Dalı

    PROF. DR. UFUK GÜNDÜZ

  5. Üst düzey basketbolcuların hazırlık dönemi süresince bazı fiziksel ve fizyolojik parametrelerinin incelenmesi

    Assessment of some physical and physiological parameters of elite baskettball players during preparatory season

    CENGİZ KURU

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    SporGazi Üniversitesi

    Beden Eğitimi ve Spor Ana Bilim Dalı

    DOÇ. DR. YAŞAR SEVİM