Çocuklarda laringeal maske airway (LMA) yerleşirilmesinin doğrulanmasında ultrasonografi kullanımının yeri

Ultrasound evaluation of laryngeal mask airway verification in children

  1. Tez No: 503968
  2. Yazar: OSMAN MÜCAHİT TOSUN
  3. Danışmanlar: DOÇ. DR. ALPER KILIÇASLAN
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Anestezi ve Reanimasyon, Anesthesiology and Reanimation
  6. Anahtar Kelimeler: Laringeal mask airway, Pediyatrik anestezi, Ultrasonografi, Pediatrik havayolu, Laryngeal mask airway, Pediatric anesthesia, Ultrasonography, Pediatric airway
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: Necmettin Erbakan Üniversitesi
  10. Enstitü: Meram Tıp Fakültesi
  11. Ana Bilim Dalı: Anesteziyoloji ve Reanimasyon Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET ÇOCUKLARDA LARİNGEAL MASKE AİRWAY (LMA) YERLEŞİRİLMESİNİN DOĞRULANMASINDA ULTRASONOGRAFİ KULLANIMININ YERİ, OSMAN MÜCAHİT TOSUN, UZMANLIK TEZİ, KONYA, 2017 Amaç: Laringeal Maske Airway (LMA) yerinin Ultrasonografi (USG) kullanılarak doğrulanması amaçlanmıştır. Yöntem: Necmettin Erbakan Üniversitesi Meram Tıp Fakültesi Yerel Etik Kurul onayı ve ebeveynlerden bilgilendirilmiş rıza alınarak; 1-12 yaş arası ASA 1-3 fiziki statüdeki 50 çocuk hasta çalışmaya dahil edildi. Anestezi indüksiyonu %8 sevoflorane + O2 6 l/dk akım inhalasyonu ile yapıldı. LMA yerleştirmeden önce ve sonra hastanın üst havayolu USG ile değerlendirildi. Dil ve aritenoid kıkırdak hizasında simetri derecesi, LMA ucunda katlanma olup olmaması ve özefagusta kaf ucunun olup olmaması değerlendirilerek görüntüler alındı. LMA içinden FOB ile laringeal yapıların görünürlük dereceleri ve larinkse göre sağa veya sola yer değiştirmesi ölçülerek, doğru veya yanlış yerleşim belirlendi. Klinik testler, USG ve FOB ile elde edilen veriler, Pearson'ın χ2 testine göre korelasyon açısından değerlendirildi. Bulgular: Klinik olarak LMA yerinin değerlendirilmesinde kullanılan havayolu basınçları ile USG ile elde edilen aritenoid kıkırdak simetri/asimetri derecesi arasında istatistiksel olarak orta düzeyde bir ilişki bulundu (R=0,59, p<0,05). FOB ile elde edilen rotasyon dereceleri ile havayolu basınçları arasındaki ilişki de aynı şekilde orta düzeydedir (R=0,596, p<0,05). Aritenoid kıkırdaklar arasındaki simetri/asimetri derecesi ile FOB rotasyon dereceleri arasında yüksek düzeyde ilişki tespit edildi (R=0,797, p<0,005). Aynı şekilde FOB ile elde edilen laringeal açıklık dereceleri ile arasındaki ilişki de yüksek düzeydedir. (R=0,672, p<0,005) Dil hizasında USG ile simetri/asimetri tespit edilmesi ve FOB rotasyon dereceleri arasında yüksek düzeyde ilişki bulunurken (R=0,710, p<0,05); FOB görüntü dereceleri arasında orta düzeyde ilişki bulunmuştur (R=0,478, p<0,05). Sonuç: LMA yerleşiminin ameliyat öncesi doğrulanması önemlidir. Ultrasonografik olarak LMA yeri, non-invaziv, hızlı, gerçek zamanlı olarak belirlenebilir. USG ile dil hizasında simetri/asimetri ve aritenoid kıkırdak asimetri derecesi belirlenerek, LMA'nın doğru yerleşip yerleşmediği, FOB'a göre daha kolay yöntemle tespit edilebilir.

Özet (Çeviri)

ABSTRACT ULTRASOUND EVALUATION OF LARYNGEAL MASK AIRWAY VERIFICATION IN CHILDREN, OSMAN MÜCAHİT TOSUN, SPECIAL PROJECT, KONYA, 2017 Objectives: In our study, we aimed to confirm the Laryngeal mask airway (LMA) placement via using Ultrasonography (USG). Methods: After approval Local Ethics Committee and informed consult of the parents of patients, we included 50 patients who were 1-12 years old and ASA 1-3 physical status. Anaesthesia induction was performed with sevoflurane 8% in oxygen with a flow rate of 6 l/min. Before and after placement of LMA, an USG specialist evaulated upper airway of the patients. The symetry/asymetry grade of the arytenoid cartilages and the asymetry degree of the LMA cuff at the tongue level were determined and noted. We also evaluated whether the LMA cuff is in the oesophagus inlet or folding of the LMA cuff. A physician who is not involved in the study evaluate the LMA position by Fiberoptic Bronchoscopy (FOB) when a T tube was placed at the tip of the LMA. The degree of rotation and laryngeal visibility were assessed and noted. Findings: There was a statistically moderate correlation between airway pressures for the clinical assessment of LMA location, and the arytenoid cartilage symmetry / asymmetry grade obtained with USG (R=0,59, p<0,05). The relationship between rotation degrees obtained with FOB and the airway pressures is moderate, too (R=0,596, p<0,05). There was a high correlation between the symmetry / asymmetry degree of the arytenoid cartilages and the rotation grades assessed via FOB examination (R=0,797, p<0,05). Likewise, the relationship between the visibility degrees of larynx and the arytenoid cartilage symetry/asymetry degree is also high (R=0,672, p<0,05). Conclusion: Preoperative confirmation of the location of the laryngeal mask airway (LMA) is important. Ultrasound is widely available, quick, portable, repeatable, relatively inexpensive and tolerable because it can provide real-time dynamic images without interrupting machine ventilation during general anesthesia. Evaluation of the degree of the symmetry/asymmetry degree of LMA suff at the tongue level and arytenoid cartilages may be useful for verifying the LMA placement.

Benzer Tezler

  1. Çocukların havayolu yönetiminde endotrakeal entübasyon tüpü ve larengeal maske kullanımının karşılaştırılması

    Başlık çevirisi yok

    ÖZLEM DELİGÖZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    Anestezi ve ReanimasyonSağlık Bakanlığı

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    UZMAN FERAY GÜLER

  2. Şaşılık cerrahisinde gelişebilen okülokardiyak refleks ile laringospazm ve uyanma ajitasyonu arasındaki ilişkinin değerlendirilmesi

    Evaluation of correlation between laryngospasm, emergence agitation and oculocardiac reflex in strabismus surgery

    AHMET ÇAKIR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    Anestezi ve ReanimasyonErciyes Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    PROF. DR. ADNAN BAYRAM

  3. Çocuklarda sevofluran fentanyl anestezisine eklenen düşük doz süksinilkolinin LMA yerleştirilmesi üzerine etkisi

    The effect of low dose succynilecholine added to sevoflurane fentanyl anesthesia on LMA insertion

    YUSUF AKDOĞAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2008

    Anestezi ve ReanimasyonDicle Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. MUSTAFA CENGİZ

  4. Hastanemizde 2019-2022 yılları arasında yanık nedeniyle tekrarlayan anestezi uygulanan çocuk hastaların hastanede kalış süresini etkileyen faktörlerin retrospektif analizi

    A retrospective analysis of the factors affecting the length of hospital stay of pediatric patients who underwent recurrent anesthesia for burns between 2019 and 2022 in our hospital

    İBRAHİM EMRE ERMAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Anestezi ve ReanimasyonSağlık Bilimleri Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. SERDAR DEMİRGAN

  5. Farklı yaş gruplarındaki pediatrik hastalarda laparoskopik inguinal herni operasyonlarında laringeal maske (LMA) ve endotrakeal entübasyonun intraoperatif ve postoperatif solunum parametrelerine etkilerinin karşılaştırılması

    The effects of laryngeal mask (LMA) and endotracheal intubation on intraoperative and postoperative respiratory parameters in laparoscopic inguinal herni operations in pediatric patients in different age groups

    DAMLA UYSAL

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    Anestezi ve ReanimasyonAnkara Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. ÖZLEM CAN