Geri Dön

Tekrarlanan fırınlama işlemlerinin, IPS Empress Sistem ile hazırlanan kronların kenar uyumuna etkisi

The Effects of repeated firing on marginal fit of crown by prepared IPS Empress System

  1. Tez No: 48676
  2. Yazar: GÜLSEN YÜKSEL
  3. Danışmanlar: DOÇ.DR. CİHAT ÇEKİÇ
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: IPS Empress Sistem, tekrarlanan fırınlama aşamaları, kenar uyumu. iv, Dental porselen, Diş-yapay, Kronlar, IPS Empress System, repeated firing, marjinal fit, Dental porcelain, Tooth-artifical, Crowns
  7. Yıl: 1996
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Belirtilmemiş.
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Fırınlamalar esnasında, metal desteksiz porselen kronlarda da, diğer sabit restorasyonlarda olduğu gibi şekil değişikliği olabilir. Bu değişim sonunda kronun, prepare edilen dişle uyumu bozulur ve plak birikimi ile birlikte gelişecek olan çürük, restorasyonun ömrünü kısaltarak, klinik başarıyı etkiler. Çalışmamızda, IPS Empress Sistem ile hazırlanan kronların kenar uyumu üzerine tekrarlanan fırınlama işlemlerinin etkisi incelenmiştir. Bu amaçla, prepare edilmiş üst santral diş şeklinde, krom nikel alaşımından, 30 adet die hazırlanmıştır. Bu die'lar üzerinde, IPS Empress Sistemi ile yine 30 adet porselen kron hazırlanmıştır. Bu örneklerin 15'ine mine porseleni uygulanıp deney grubu olarak alınırken, diğer 15'i mine porseleni uygulanmaksızın kontrol grubu olarak alınmıştır. Her iki gruba bağlantı, boyama, düzeltme, mine porseleni uygulama, glaze 1 ve glaze 2 olmak üzere 6 fırınlama aşaması uygulanmıştır. Başlangıç aşaması ile birlikte tüm fırınlamalardan sonra, örneklerin kenarlarındaki rehber noktalar arası mesafe, stereoptik mikroskopta ölçülmüştür. Çalışmamızda, bu sistemle hazırlanan kronların, kenar uyumlarının tekrarlanan fırınlama işlemlerinden etkilendikleri ve bu nedenle son derece dikkatli hazırlanmaları gerektiği sonucuna ulaşılmıştır.

Özet (Çeviri)

ABSTRACT During the firing procedures, there may be marginal discrepencies in the porcelain fused to metal restorations just like the conventional fixed partial dentures. This marginal gap may lead to a carious due to accumulation of plaque and compromise the success of the materials. This study evaluates, the relation between the marginal fit with the repeating firings of the crowns that were constructed by IPS Empress System. For this purpose, 30 Ni-Cr dies were used to built 30 porcelain crowns by using IPS Empress System. These dies were divided into 2 groups as experimental and control. In the experimental group which was formed with 15 dies, incisal porcelains were applied on the crowns. In the control group, all crowns were built without incisal porcelain. The crowns in both groups were fired 6 times for wash firing, characterization firing, incisal firing, corrective firing, glaze I firing and glaze II firing. The marginal gap of the crowns, were measured between the reference points by steroptic microscope. From the starting phase and after each firing procedures, measurements were repeated to evaluate the marginal gap of the crowns. As a conclusion, the marginal adaptation of the crowns in the experimental groups, were affected by repeating firings. So care must be taken in the laboratory procedures, for the marginal fit of the IPS Empress System crowns.

Benzer Tezler

  1. Farklı fırınlamaların metal porselen bağlantısı üzerindeki rolü

    Başlık çevirisi yok

    MEHMET DALKIZ

    Doktora

    Türkçe

    Türkçe

    1992

    Diş HekimliğiGata

    Protetik Diş Tedavisi Ana Bilim Dalı

  2. Düşük ısı porselenlerinin temel metal alaşımları ile kullanılmasında bazı fiziksel özelliklerinin değerlendirilmesi

    The Evaluation of physical properties of low fusing porcelains used with base alloys

    EMRE KARAAĞAÇ

    Doktora

    Türkçe

    Türkçe

    2001

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF.DR. ALİ ZAİMOĞLU

  3. Türkiye'de alçı bazlı ürünlerin kullanımı ve anhidrit alçısının özelliklerinin tayin edilmesi, üretim prosesi ve kullanım yerlerinin incelenmesi

    Investigation of the usage of the different kinds of gypsum based products in Turkey and determination of the specifications of anhydrous gypsum, production process and usage

    BATUHAN ALİ AKKAYA

    Yüksek Lisans

    Türkçe

    Türkçe

    1999

    Kimya MühendisliğiHacettepe Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    PROF.DR. AHMET ÖZDURAL

  4. Titanyum, Vi-comp ve remanium-CS destekli porselen kronlarının pişirme aşamalarının sonundaki marjinal uyumlarının karşılaştırılması

    Marginal distortion of titanyum, Vi-comp and remanium-CS metal ceramic restorations during the porcelain firing procedure

    ARSUN ÇULHA

    Doktora

    Türkçe

    Türkçe

    1997

    Diş HekimliğiHacettepe Üniversitesi

    Protez Ana Bilim Dalı

    PROF. DR. YAVUZ ASLAN