Geri Dön

Farklı boyun tasarımına sahip iki implant sisteminin tam dişsiz alt çenelerde marjinal kemik kaybına ve kemik içi stabiliteye etkisinin incelenmesi

Comparison of two different implant crest module designs from the standpoint of effects on marginal bone loss and implant stabilization in mandibular overdentures

  1. Tez No: 482880
  2. Yazar: ÖZGE ERDOĞAN YILMAZ
  3. Danışmanlar: PROF. DR. TAYFUN BİLGİN
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental implantasyon, Dental implantlar, Frekans analizi, Kemik defektleri, Rezonans, Takma diş-tam, Takma dişler, Dental implantation, Dental implants, Frequency analysis, Bone defects, Resonance, Denture complete, Dentures
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Dental implantlarda odaklanılan çalışmalar implantların başarı ve sağkalım oranlarından implantların başarı ve sağkalımlarının kalitesine doğru yönelmektedir. İmplant boyun bölgesi tasarımlarını diğer komponentlerden farklı kılan, fonksiyon altında oluşan streslerin en yoğun şekilde implant boynu etrafındaki krestal kemik çevresinde gözlenmesidir. Bu çalışmanın amacı boyun bölgesi kemik seviyesinde (Dentis® s-Clean) ve dişeti seviyesinde (Dentis® i-Clean) sonlanan farklı boyun bölge dizaynına sahip iki tür dental implant sisteminin kemik içi stabilite değerlerinin ve marjinal kemik kayıplarının karşılaştırmalı olarak incelenmesidir. Çalışmada yer alan 26 tam dişsiz hastaya 33 numaralı bölgeye 26 adet Dentis® i-Clean implant, 43 numaralı bölgeye de aynı boy ve çapta 26 adet Dentis® s-Clean implant uygulanmıştır. Tüm hastalar Locator tutucu destekli overdenture protezlerle rehabilite edilmiştir. İmplant stabilizasyon değerlerinin belirlenmesinde rezonans frekans analizinden yararlanılmış ve her bir implant için cerrahi operasyon sırasında, 1., 4. ve 6. haftada, 6. ve 12. ayda elde edilen veriler değerlendirilmiştir. Marjinal kemik kaybı miktarı cerrahi işlemi takiben, 6. haftada, 6. ayda ve 12. ayda olmak üzere 4 kez alınan dijital panoramik röntgenler aracılığı ile hesaplanmıştır. s-Clean ve i-Clean implantların ISQ değerleri ortalamaları arasında anlamlı bir farklılık bulunmamıştır (p>0.05). Tüm ölçümlerde marjinal kemik kaybı miktarlarında implantlar arasında istatistiksel olarak anlamlı bir farklılık gözlenmemiştir (p>0.05). Sonuçlarda primer stabilizasyon ISQ değeri ile genişletilmiş platform özelliği gösteren s-Clean implantların 6. ay MKK düzeyleri arasında istatistiksel olarak anlamlı bir korelasyon tespit edilmiştir (p:0.018; p<0.05) ancak bu durum 12. ayda dengelenmiş ve iki implant grubu arasındaki istatistiksel fark ortadan kalkmıştır

Özet (Çeviri)

The main focus of studies regarding dental implants has begun shifting towards the quality of implant success and survival rates rather than merely success and survival rates. Implant crest module differs from other components by being in the most critical position where initial breakdown of periimplant bone takes place. The aim of this study is to compare bone level (Dentis® s-Clean) and tissue level (Dentis® i-Clean) implants from the standpoint of effects on marginal bone loss and implant stabilization in mandibular overdentures with Locator attachments. 26 completely edentulous patients received 2 implants which are number 33 being tissue level i-Clean and number 43 being bone level s-Clean in the canine area of mandible. RFA method was used to measure implant stability values during the surgery and 1st, 4th, 6th weeks, 6th and 12th months after implant placement. Marginal bone loss around implants were monitored via panoramic radiographs obtained immediately after surgery and during the 6th week, 6th and 12th month control sessions after implant placement. No significant differences were detected between the ISQ values of s-Clean and i-Clean implants (p>0.05). The results were also insignificant between marginal bone losses of s-Clean and i-Clean implants for all of the measurements (p>0.05). Though no significant differences were found between the ISQ values and marginal bone loss for both implant groups at end of the follow-up time of 1 year; the statistical analysis revealed a significant correlation between primary stabilization values of s-Clean implants and 6th month marginal bone loss levels (p:0.018; p<0.05).

Benzer Tezler

  1. İşitme engelliler için homojen alan dağılımlı gişe tipi ses frekansı indüksiyon döngü sistemi tasarımı

    Uniform field distribution audio frequency counter induction loop design for hearing impaired

    MELTEM LORDOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektrik Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ DENİZ YILDIRIM

    DOÇ. DR. SERHAT İKİZOĞLU

  2. Farklı kemik yoğunluklarında, switch platformlu iki farklı implant sisteminin boyun bölgelerinde meydana gelen kemik rezorbsiyonunun üç boyutlu sonlu elemanlar analizi ile incelenmesi

    An investigation of three dimensional finite elements analysis of bone resorption at the neck area of two different implant systems which switch platform feature on different bone density

    ADALET ÇELEBİ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiDicle Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. BELGİN GÜLSÜN

  3. Hex ve non-hex vidalı dayanaklarla hazırlanan implant üstü restorasyonların sonlu elemanlar analiz yöntemi ile karşılaştırılması

    Comparison of implant supported restorations produced with hex and non-hex screw abutments concept with finite element analysis method

    HASAN ALPAY ÇELİK

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiHatay Mustafa Kemal Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. MUSTAFA ZORTUK

  4. MEMS sensor platform for vital monitoring under mri and intraocular pressure measurement

    Yaşamsal işaretlerin ve göz içi basıncın ölçülmesine yönelik MEMS basınç ölçer platformunun geliştirilmesi

    PARVIZ ZOLFAGHARI

    Doktora

    İngilizce

    İngilizce

    2023

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ONUR FERHANOĞLU

  5. Mandibulanın farklı ark formlarında dört implant ile tedavisinde implant açılarının ve trabeküler yüzey yapılı implantların kemik üzerine etkilerinin sonlu elemanlar analizi ile incelenmesi

    Finite element analysis of the effects of implant angles and trabecular surface implants on bone in the treatment of mandible with four implants in different arch forms

    AHMET İLTER ATAY

    Doktora

    Türkçe

    Türkçe

    2025

    Diş Hekimliğiİstanbul Üniversitesi

    Oral İmplantoloji Ana Bilim Dalı

    PROF. DR. SERDAR YALÇIN