Truebeam 2.0 STX cihazında cihaz kabulü sırasında tedavi planlama sistemine girilen parametrelerin tedavi plan kalitesine etkisi

The effects of treatement planning system configuration parameters defined during to truebeam 2.0 STX commissioning on treatement plan quality

  1. Tez No: 471554
  2. Yazar: EMRE ŞANLI
  3. Danışmanlar: DOÇ. DR. HİLAL ACAR DEMİR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Doz-cevap ilişkisi-radyasyon, Planlama, Radyasyon, Radyasyon dozajı, Radyasyon onkolojisi, Radyometri, Radyoterapi, Radyoterapi-bilgisayar yardımlı, Tedavi, Dose-response relationship-radiation, Planning, Radiation, Radiation dosage, Radiation oncology, Radiometry, Radiotherapy, Radiotherapy-computer assisted, Treatment
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: İstanbul Medipol Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Sağlık Fiziği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Radyoterapi tedavi sürecinde kullanılan Tedavi Planlama Sistemleri (TPS) uygulanan tedavilerin doğruluk ve kalitesi üzerinde doğrudan etkiye sahiptirler. Radyoterapi tedavilerinde doz hesaplamasında kullanılan doz hesaplama algoritmaları, kullanmakta oldukları cihaz modellemesi, radyasyon taşıma modellemesi ve doz hesaplaması modülü gibi sahip oldukları temel farklılıklar dolayısıyla farklı klinik koşullar için farklı sonuçlar verebilmekte ve tedavi doğruluğuna etkide bulunabilmektedirler. Bu çalışmanın amacı, Eclipse TPS içerisinde TrueBeam STx 2.0 tedavi cihazı kabulü sırasında tanımlanan cihaz yapılandırma parametrelerinin doz hesaplama doğruğuna olası katkı ve etkilerinin, oluşturulan tedavi planları ve doğrulama ölçümlerinin karşılaştırılması üzerinden incelenmesidir. Çalışmada Eclipse TPS içerisinde kullanıcının tanımlaması gereken "efektif spot boyutu (SP), dozimetrik yaprak aralığı (DLG) ve yaprak geçirgenliği (LT) parametrelerinin, kolimatör çene yada çok yapraklı kolimatörler (MLC) tarafından sınırlandırılmış durağan alanlar ve hacimsel ayarlamalı ark terapi (VMAT) tedavi tekniği ile gerçekleştirilmiş tedavi planlamaları için AAA ve Acuros XB algoritmalarıı tarafından hesaplatılan dozlar üzerine etkileri araştırılmıştır. Durağan alan tedavi planları için TPS 'de sanal bir su eşdeğeri fantom üzerinde doz hesaplaması yapılmıştır. VMAT planları için bir adet hastaya ait beyin bölgesindeki farklı boyutlarda konturlanan sanal hedef hacimler üzerine optimizasyon yapıldıktan sonra doz hesaplama işlemleri gerçekleştirilmiştir. Plan doğrulama ölçümleriyle 2 boyutlu doz dağılımı ve mutlak doz karşılaştırmaları yapılmıştır.

Özet (Çeviri)

Treatement Planning Systems (TPS) used in the radiotherapy treatement process have a big importance on the accuracy and quality of implemented treatement. Dose calculation algorithms which is employed to calculate dose in radiotherapy treatement have fundamental differences as treatement devices modelling, radiation transport modelling and dose calculation modelling which are underlied the algorithm, therefore these differences may arise different results in different clinical condition. Purpose of the this study is to investigate probable effect of treatement machine configuration parameters defined at commissioning process on the dose calculation accuracy. In this study, Eclipse Algorithms AAA and Acuros XB were configured by different values of configuration parameters“Effective Spot Size (SP), Dosimetric Leaf Gap (DLG) and Leaf Transmission (LT).”Then Dose calculation performed with the dose calculation algorithms via these parameters for created plans with different techniques (static jaw defined, static Multi Leaf Collimator (MLC) defined and Volumetric Modulated Arc Therapy (VMAT) technique). For static plans doses calculated on a virtual water phantom created in Eclipse TPS. For VMAT plans, three virtual spherical target volumes consist of different diameter were contoured on a Computed Tomography (CT) image belonging to a patient's cranium. Dose calculation were performed after optimisation process on these target volumes. After all, absolute dose and 2D dose distribution comparisons are performed between result of the dose calculation and verification measurements.

Benzer Tezler

  1. Görüntü kılavuzluğunda radyoterapi uygulanan pelvik maligniteli hastalarda vücut kitle indeksi' nin set-up güvenilirliğine etkisi

    Effect of body mass index on set-up errors in patients treated with image guided radiotherapy for pelvic malignancies

    OKAN ÖZDEMİR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2015

    OnkolojiDokuz Eylül Üniversitesi

    Radyoloji Onkolojisi Ana Bilim Dalı

    DOÇ. DR. LÜTFİYE ZÜMRE ARICAN ALICIKUŞ

  2. Radyoterapide yüksek enerjili foton ve nötron ışınları için zırhlama hesaplama yöntemlerinin karşılaştırılması

    Comparison of shielding calculation methods for high energy photon and neutron beams in radiotherapy

    MUHAMMET MUSTAFA TİNTAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    OnkolojiDokuz Eylül Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. FADİME AKMAN

    YRD. DOÇ. DR. AYŞEGÜL YURT

  3. VMAT tekniği kullanılarak yapılan tedavi planlarının hastaya özel doğrulamasında farklı yöntemlerle elde edilen gamma indeks değerlerinin karşılaştırılması

    Comparison of gamma index values obtained by different methods in patient specific verification of treatment plans using VMAT technique

    MUSTAFA BUDAK

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    OnkolojiAcıbadem Mehmet Ali Aydınlar Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. KAZIM MERİÇ ŞENGÖZ

  4. Vestibular schwannoma hastalarında farklı radyocerrahi tekniklerinin dozimetrik olarak karşılaştırılması

    Başlık çevirisi yok

    MELTEM YILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    OnkolojiAcıbadem Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    DOÇ. DR. KAZIM MERİÇ ŞENGÖZ

  5. Volümetrik ark tedavi tekniği ile pelvik radyoterapi uygulanan hastalarda flattening filter free kullanımının etkisi

    The effect of FFF for patients receiving pelvic radiotheraphy using vomumetric modulated arc therapy (VMAT) tecnique

    ELVİN ERDOĞAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    OnkolojiAcıbadem Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. MELAHAT GARİPAĞAOĞLU