Özelliklerini yitirmiş diz ekleminin metal ana bileşenler ve polimer esaslı ara bileşenler ile yenilenmesi olarak bilinen Total Diz Artroplastisi (TDA)'nde kullanılan Total Diz Protezi (TDP) için ortalama ömür değeri 15-20 yıl arasındadır. TDA tedavisine ihtiyaç duyan hasta yaşının giderek düşmesi bu dayanım süresinin yetersizliğine ve sonuçta da revizyon ameliyatına sebep olmaktadır. Revizyon operasyonlarının başarısı ilk TDA'lardan çok daha düşük olduğundan hastanın devam eden yaşantısında kritik bir süreci başlatmaktadır. TDP'lerde meydana gelen hasarları azaltıp kullanım ömrünü artırmak amacıyla son yıllarda kişiye özel tasarımlar kullanılmaktadır. Bu çalışmada, anatomik kemik modeline tam uyumlu olarak tasarlanan TDP bileşenleri ile üç boyutlu kemik modelleri, bilgisayar ortamında montajlanmıştır. Montajlanan tüm kemik ve bileşenler sonlu elemanlar metodu ile deterministik ve olasılık esaslı analizler ile incelenmiş ve analiz sonuçları dikkate alınarak tasarlanan hastaya özel protez bileşenleri, lazer sinterleme yöntemi ile üretimi yapılmıştır. Yapay kemik modelleri ile tasarlanan protezler ilgili ortopedist tarafından gerçek ortamda montajlanmış ve statik yükleme altında kemik şekil değişimleri incelenmiştir. Deneysel testler ile sonlu elemanlar analizinden alınan sonuçlar karşılaştırılarak modelin doğruluğu değerlendirilmiştir. Çalışma sonucunda tasarlanan hastaya özel protezin, geleneksel proteze göre kemik çimentosu-kemik ara yüzeyinde daha az deplasmana, insert-femoral bileşen ara yüzeyinde daha az temas basıncına maruz kaldığı ve daha iyi kemik-protez uyumuna sahip olduğu belirlenmiştir.
Özet (Çeviri)
The average life of a Total Knee Prosthesis (TKP) that is used in the total knee arthroplasty (TKA) known as replacement of degenerated knee joints by main metal components and polyethylene based intermediate components is approximately between 15 and 20 years. The fact that the age of patients who needs TKA gradually drops causes insufficiency of the life of the prosthesis, and ultimately the need for a revision operation. Since the success rate of revision operations is significantly lower than that of the first TKAs, a critical period for the patient starts for his/her life left. In recent years, patient-specific design has been used to eliminate failures occurred at the TKP as well as increasing the usage life. In this study, three dimensional bone models along with the TKP components that were designed as full-compatible to the anatomical bone model were assembled in a computer program. The full model including all the bones and components were studied by deterministic and probabilistic analysis based on the finite element method, and the patient-specific components of the prosthesis that was designed in this study were manufactured using the laser melting method, considering the results from the analyses. The orthopaedist concerned assembled the artificial bone models with the prosthesis designed, and the strain behaviour under static loading was investigated. The finite element model was verified by comparing the results from the experiments and the finite element analysis. As a result of this study, compared to functional prosthesis, it is found out that patient-specific prosthesis proposed is exposed less strain on the interface of bond-cement, less contact pressure on the interface of insert-femoral component and provides better compliance between bone and prosthesis.
Benzer Tezler
- Kişiye özel bilgisayarlı tomografi görüntüleriyle diz protezinin modellenmesi ve sonlu elemanlar analizi ile değerlendirilmesi
Designing knee implant using patient-specific computerized tomography images and evaluating it by finite element analysis
İSMAİL HAKKI KORKMAZ
Yüksek Lisans
Türkçe
2011
Makine MühendisliğiAtatürk ÜniversitesiMakine Mühendisliği Bölümü
DOÇ. DR. İRFAN KAYMAZ
- Türk toplumunda distal femur ve proksimal tibianın rotasyonel ve morfometrik özelliklerinin total diz protezi uygulaması ışığında değerlendirilmesi
Evaluation of rotational and morphometric features of distal femur and proximal tibia in the light of total knee prosthesis in Turkish population
GÖKHAN DOĞANCI
Tıpta Uzmanlık
Türkçe
2019
Ortopedi ve TravmatolojiSağlık Bilimleri ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
UZMAN ADİL TURAN
- CAD datası olmayan parçaların tersine mühendislik metodu ile CAD datalarının oluşturulması
CAD data without parts, reverse engineering and method formation of CAD datas
HAKKI DEMİR
Yüksek Lisans
Türkçe
2018
Makine MühendisliğiFırat ÜniversitesiMakine Eğitimi Ana Bilim Dalı
PROF. DR. VEDAT SAVAŞ
- Artroplasti geçirmiş diz osteoartritli olguların ağrı, eklem hareket açıklığı, denge, fiziksel aktivite ve yaşam kalitesi düzeylerinin değerlendirilmesi
Assessment of pain,range of motion,balance, physical activity and live quality in patients with osteoarthritis of the knee arthroplasty
GÜLER BÜYÜKYILMAZ
Yüksek Lisans
Türkçe
2015
Fiziksel Tıp ve RehabilitasyonTrakya ÜniversitesiFizik Tedavi ve Rehabilitasyon Ana Bilim Dalı
PROF. DR. MURAT BİRTANE
DOÇ. DR. DERYA DEMİRBAĞ KABAYEL
- Nesnelerin interneti yöntemi ile diz açısı belirleme sisteminin geliştirilmesi
Development of knee angle determination system based on internet of things
SÜMEYRA BÜŞRA ŞENGÜL
Yüksek Lisans
Türkçe
2018
Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolNecmettin Erbakan ÜniversitesiEndüstri Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ ABDULLAH ERDAL TÜMER