Geri Dön

Cyberknife ile stereotaktik vertebra radyoterapisinde ray-trace ve monte carlo hesaplama algoritmalarının dozimetrik karşılaştırılması

Dosimetric comparison of ray-trace and monte carlo calculation algorithms at stereotactic spine radiotherapy with cyberknife

  1. Tez No: 412474
  2. Yazar: ALİ EFETÜRK
  3. Danışmanlar: YRD. DOÇ. MURAT OKUTAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Onkoloji, Physics and Physics Engineering, Oncology
  6. Anahtar Kelimeler: Algoritmalar, Neoplazmlar, Radyasyon dozajı, Radyocerrahi, Radyometri, Radyoterapi, Radyoterapi-bilgisayar yardımlı, Stereotaksik teknikler, Tedavi, Algorithms, Neoplasms, Radiation dosage, Radiosurgery, Radiometry, Radiotherapy, Radiotherapy-computer assisted, Stereotaxic techniques, Treatment
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Temel Onkoloji Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Stereotaktik vertebra radyoterapisinde CyberKnife cihazı ile ray-trace ve monte carlo hesaplama algoritmaları kullanılarak fantom üzerinde çizilen, kritik organ dozlarının TPS verileri ve gerçekte ölçülen dozlarını karşılaştırarak algoritmaların doz dağılımları üzerindeki etkisinin incelenmesi amaçlanmıştır. İnsan benzeri fantomda sanal olarak oluşturulan T8 seviyesinde bulunan vertebra tümörünün, CyberKnife cihazıyla tedavisinde Multiplan tedavi planlama sisteminde ray trace ve monte carlo algoritmaları kullanılarak elde edilen dozlar tespit edilmiştir. Ayrıca,tedavi planlamasında belirlenmiş riskli organlar için ( omurilik, kalp, akciğer ve akciğer doku birleşimi ) yerleştirilen film ve TLD ile ölçülen dozlar planlama bilgisayarındaki aynı noktalarla karşılaştırılmıştır. CK cihazında ışınlanan omurilik, kalp, akciğer ve akciğer doku birleşimindeki dozları ray-trace algoritması kullanılarak TLD ile sırasıyla ortalama; 487±2,51 cGy, 26±2 cGy, 67±3,6 cGy, 202±2,51 cGy ve film ile sırasıyla ortalama; 490±2,64 cGy, 27±2 cGy, 75±1 cGy, 202±2,64 cGy olarak, monte carlo algoritması ile %2 belirsizlikle hesaplanarak TLD ile sırasıyla ortalama; 480±3 cGy, 26±1,7 cGy, 77±9,16 cGy, 215±5,5 cGy ve film ile sırasıyla ortalama; 485±5 cGy, 26±3,6 cGy, 76±6 cGy, 205±8,6 cGy olarak, monte carlo algoritması %1 belirsizlikle hesaplanarak TLD ile sırasıyla ortalama; 345±1 cGy, 19,6±2,51 cGy, 68±1 cGy, 167±4,58 cGy ve film ile sırasıyla ortalama; 352±7,21 cGy, 20±1,7 cGy, 67,6±2,3 cGy, 168±7,5 cGy olarak, monte carlo algoritması ile %0,2 belirsizlik ile hesaplanarak TLD ile sırasıyla ortalama; 397±2 cGy, 21,6±1,52 cGy, 72±7,2 cGy, 170±1 cGy ve film ile sırasıyla ortalama; 396±3,46 cGy, 20,3±1,5 cGy, 76,6±4,1 cGy, 175±4,58 cGy olarak ölçülmüştür. Ayrıca Monte Carlo algoritması kullanıldığında belirsizlik azaltılınca planlama ve ışınlama süreleri artmaktadır.

Özet (Çeviri)

By using Ray-Trace and monte carlo calculation algorithms with CyberKnife device at Stereotactic Spine Radiotherapy and by comparing drawn on a phantom, critical organ doses of TPS data and actually measured doses, It aimed to investigate effect on the dose distribution of algorithms. human-like virtual phantom created in which the level of T8 vertebra tumor at treatment with CyberKnife device In multiple treatment planning system, the dose obtained was determined by using Ray-Trace and monte carlo calculation algorithms. In addition, The doses measured by the placed film and TLD for risk organs defined in treatment planning (Spinal cord, heart, lung and lung tissue combination) was compared with the same point in the planning computer. Doses in İrradiated spinal cord, heart, lung and lung tissue combination with CK device, by using Ray-Trace algorithm with TLD 487±2,51 cGy, 26±2 cGy, 67±3,6 cGy, 202±2,51 cGy and with film 490±2,64 cGy, 27±2 cGy, 75±1 cGy, 202±2,64 cGy, by calculating %2 uncertainty in monte carlo algorithm with TLD 480±3 cGy, 26±1,7 cGy, 77±9,16 cGy, 215±5,5 cGy and with film 485±5 cGy, 26±3,6 cGy, 76±6 cGy, 205±8,6 cGy, by calculating %1 uncertainty in monte carlo algorithm with TLD 345±1 cGy, 19,6±2,51 cGy, 68±1 cGy, 167±4,58 cGy and with film 352±7,21 cGy, 20±1,7 cGy, 67,6±2,3 cGy, 168±7,5 cGy, by calculating %0,2 uncertainty in monte carlo algorithm with TLD 397±2 cGy, 21,6±1,52 cGy, 72±7,2 cGy, 170±1 cGy and with film 396±3,46 cGy, 20,3±1,5 cGy, 76,6±4,1 cGy, 175±4,58 cGy was measured respectively. Also, if uncertainty is reduced when used monte carlo algorithm, planning and irradiation times increase.

Benzer Tezler

  1. Cyberknife® X-sight® vertebra takip sisteminin vertebra dışı lezyonlarda uygulanabilirliğinin araştırılması

    Investigating the feasibility of out of spine application of cyberknife® X-sight™ spine tracking system

    SELAMİ EKEN

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    OnkolojiHacettepe Üniversitesi

    Radyoloji Onkolojisi Ana Bilim Dalı

    PROF. DR. ABDULLAH FARUK ZORLU

  2. Vertebra ışınlamalarında farklı tedavi tekniklerinin dozimetrik olarak incelenmesi

    Investi̇gati̇on of di̇fferent dosi̇metri̇c treatment techni̇cs i̇n spine irradiation

    ADEM GÜNEN

    Yüksek Lisans

    Türkçe

    Türkçe

    2015

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    YRD. DOÇ. DR. MURAT OKUTAN

  3. Cyberknıfe ve lıneer hızlandırıcı tabanlı vertebral stereotaktı̇k radyoterapı̇ tedavı̇lerı̇nı̇n dozı̇metrı̇k karşılaştırılması

    Dosimetric comparison of cyberknife and linear accelerator based vertebral stereotactic radiotherapy treatments

    EBRU ORUÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    OnkolojiAcıbadem Mehmet Ali Aydınlar Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    DOÇ. DR. BANU ATALAR

  4. Akciğer kanserli olgularda stereotaktik ablatif beden radyoterapisi kalite kontrolleri için hastaya özgü tümör ve solunum izlemi fantomu tasarımı

    Quality assurance of patient specific tumor and respiratory tracking phantom design of stereotactic ablative body radiotherapy in lung cancer patients

    TAHA ERDOĞAN

    Doktora

    Türkçe

    Türkçe

    2020

    OnkolojiHacettepe Üniversitesi

    Radyoterapi Fiziği Bilim Dalı

    PROF. DR. GÖKHAN ÖZYİĞİT

  5. Akciğer kanserinin cyberknife ile stereotaktik radyoterapisinde ray-trace ve monte carlo hesaplama algoritmalarıyla elde edilen doz dağılımlarının karşılaştırılması

    Comparison of dose distributions to obtained by ray-trace and monte carlo calculation algorithms for with cyberknife stereotactic radiotherapy of lung cancer

    İSMAİL FARUK DURMUŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Onkoloji Ana Bilim Dalı

    PROF. DR. GÖNÜL KEMİKLER