Birleşik bilgisayarlı tek foton emisyon tomografisi/bilgisayarlı tomografi (SPECT/CT) ile birleşik pozitron emisyon tomografisi/bilgisayarlı tomografi (PET/CT) sistemlerinde tomografik görüntülere sistem yazılım parametrelerinin etkisinin incelenmesi
Investigation of the system software parameters effects on the tomographic images in the combined single photon emission computed tomography/ computed tomography (SPECT/CT) and combined positron emission tomography/ computed tomography (PET/CT) systems
- Tez No: 406422
- Danışmanlar: DOÇ. DR. TURAN OLĞAR
- Tez Türü: Yüksek Lisans
- Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2015
- Dil: Türkçe
- Üniversite: Ankara Üniversitesi
- Enstitü: Nükleer Bilimler Enstitüsü
- Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
- Bilim Dalı: Sağlık Fiziği Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Nükleer Tıp görüntüleri organ fonksiyonlarının saptanması ile ilgili önemli bilgi sağlar. Bilgisayarlı Tek Foton Emisyon Tomografi (Single Photon Emission Computed Tomography, SPECT) ve Pozitron Emisyon Tomografisi (Positron Emission Tomography, PET) sistemleri bu amaç için kullanılan başlıca sistemlerdir. Nükleer tıp uygulamalarında hastalığın doğru teşhisini sağlayan optimum görüntü kalitesi için bu sistemlerin kalite kontrol ve performans testlerinin yapılması gereklidir. Bu çalışmanın amacı, nükleer tıp görüntüleme sistemlerinde kullanılan tomografik görüntü oluşturma yöntemleri ve görüntü işleme parametrelerinin görüntü kalitesine etkisinin araştırılmasıdır. Bu amaç doğrultusunda tomografik görüntüler, bir SPECT ve bir PET sistemi kullanılarak farklı performans ölçüm fantomları (Jaszczak, Hoffman 3-D Beyin Fantomu) aracılığıyla filtre geriye projeksiyon (Filtered Back Projection, FBP) ve tekrarlayıcı (3D-Ordered Subset Expectation Maximization, OSEM) kesit görüntüsü elde etme yöntemleri ve farklı görüntü işleme parametreleri (filtre, tekrar sayısı, alt grup sayısı, filtre genişliği ve büyütme faktörü) kullanılarak oluşturulmuştur. Foton azalım düzeltmesi için, SPECT ve PET sistemleri ile birleşik olarak kullanılan bilgisayarlı tomografi (BT) sistemlerinden elde edilen transmisyon görüntüleri kullanılmıştır. Farklı parametre ile oluşturulmuş her görüntü üzerinde % rms, kontrast, homojenite, kontrast gürültü oranı (Contrast to Noise Ratio, CNR), radyoaktif tutulum oranı (Radioactivity Concentration Ratio, RCR)ve tomografik uzaysal ayırma gücü (FWHM) ölçülmüştür. Ölçümler sonucunda, uzaysal ayırma gücünün ve kontrastın PET sisteminde SPECT sistemine göre daha yüksek olduğu, 3D-OSEM tekrarlayıcı teknikte ise 4-6 tekrar ve 8-16 alt grup seçiminin kabul edilebilir bir görüntü kalitesi için optimum olduğu sonucuna varılmıştır.
Özet (Çeviri)
Nuclear medicine images provides important information about metabolic abnormality of the organs. SPECT and PET systems are the main imaging systems using for this purpose. Quality control and performance tests of these systems are necessary for the optimum image quality required for correct diagnosis in nuclear medicine applications. The aim of this study is to investigate effect of tomographic image reconstruction methods and different image processing algorithms on tomographic image quality. for this purpose, tomographic images were reconstructed by using both filtered back projection and 3D-OSEM tomographic images reconstruction methods and different image processing parameters like filter, iteration number, subset number, filter width and zoom factor and different performance measurement phantoms (Jaszczak, Hoffman 3D- Brain phantom) for each SPECT and PET imaging systems. For foton attenuation correction in both SPECT and PET, CT transmission images were used. Relative noise (% rms – %root mean square), contrast, homogeneity, contrast- noise ratio (CNR), radioactivity concentration ratio and spatial resolution were measured for each tomographic image formed by using different prameters. As a result of the measurements, the spatial resolution and contrast in the PET system were better than that in SPECT system and 4-6 iterations and 8-16 subsets for 3D-OSEM method were observed as the optimum choice for acceptable image quality.
Benzer Tezler
- quantitative Imaging with Y-90 Bremsstrahlung SPECT/CT (Single Positron Emission Computed Tomography)
Kantitatif Y-90 Bremsstrahlung SPECT/BT (Tek Foton Emisyon Tomografisi/Bilgisayarlı Tomografi) Görüntülemesi
SEVAL BEYKAN
Yüksek Lisans
İngilizce
2014
Radyoloji ve Nükleer TıpRuprecht-Karls-Unıversıtat-HeıdelbergSağlık Fiziği Ana Bilim Dalı
PROF. DR. MİCHAEL LASSMAN
- 99mTc ile işaretli madecassoside ve enkapsüle edilmiş madecassoside bileşiklerinin sentezi ve parkinson hastalığının teşhisinde kullanılabilirliğinin ın vitro/ın vivo yöntemlerle tespiti
The synthesis of encapsulated madecassoside and radiolabeled madecassoside with 99mTc and the determination the availability of utilizing in diagnosis of parkinson's disease with in vitro / in vivo methods
EMRE UYGUR
Doktora
Türkçe
2020
Radyoloji ve Nükleer TıpEge ÜniversitesiNükleer Bilimler Ana Bilim Dalı
PROF. DR. FAZİLET ZÜMRÜT BİBER MÜFTÜLER
- Medikal radyoizotop üretimi için nükleer model hesaplamaları ve veri elde edilmesi
Nuclear model calculations and data obtaining for production of medical radioisotopes
OZAN ARTUN
Doktora
Türkçe
2015
Nükleer MühendislikBülent Ecevit ÜniversitesiFizik Ana Bilim Dalı
PROF. DR. HÜSEYİN AYTEKİN
- Tüm vücut cilt ışınlamalarında foton kullanımının dozimetrik değerlendirilmesi
Dosimetric evaluation of photon use in whole body skin irradiation
MEHMET ALİ KAYA
Doktora
Türkçe
2023
Radyasyon OnkolojisiDicle ÜniversitesiFizik Ana Bilim Dalı
PROF. DR. MEHMET ZAFER KÖYLÜ
- Modulation response of A 1.55 mm InGaAsP semiconductor laser diode
Yarı iletken 1.55 mm InGaAsP lazer diyodunun modülasyon tepkisi
M.EMİN TAĞLUK
Yüksek Lisans
İngilizce
1992
Elektrik ve Elektronik MühendisliğiGaziantep ÜniversitesiDOÇ. DR. M. S. ÖZYAZICI