Klorheksidin jelin farklı implant sistemlerinde abutment vidası üzerine etkilerinin karşılaştırmalı olarak incelenmesi

The effect of chlorhexidine gel on removal torque values of different dental implant systems

  1. Tez No: 342032
  2. Yazar: KEREM ÖZDEMİR
  3. Danışmanlar: PROF. DR. ENDER KAZAZOĞLU
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental implant, Klorheksidin, Geri söküm torku iii, Dental implantasyon, Dental implantlar, Kemik vidaları, Dental Implants, Chlorhexidine, Removal Torque, Dental implantation, Dental implants, Bone screws
  7. Yıl: 2012
  8. Dil: Türkçe
  9. Üniversite: Yeditepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

mplant tedavisi gelişen teknolojisi sayesınde tek diş eksikliklerinde, pariyel ve total dişsizlik vakalarında sıklıkla ve başarı ile kullanılan vazgeçilmez bir tedavi seçeneğidir. İmplant tedavisi tüm bu avantajlarına rağmen mekanik ve biyolojik komplikasyonlarınedeniyle klinisyenleri sıkıntıya sokan durumlar oluşturmaktadır. Bu mekanik ve biyolojik komplikasyonlar içersinde en sık karşılaşılan komplikasyonlar vida gevşemesi ve kronik peri-implanitistir. Bu çalışmanın amacı implant abutment birleşimine lubrikant bir ajan olan klorheksidin jel uygulamasının abutment vidalarının geri sökülme tork değerleri üzerine biyolojik açıdan olduğu gibi mekanik bir katkısının da olup olmadığı incelemektir. Toplamda 24 adet yeni implant, abutment ve vidaları(Astra, Zimmer, Straumann Bone Level, Straumann Standart Plus) akrilik rezin içine gömüldükten sonra kuru ve klorheksidin uygulanacak iki gruba ayrıldı. Klorheksidin grubunda implant abutment vidasının arasındaki yivlere klorheksidin jel uygulanırken, kuru grupta herhangi bir ajan uygulanmayarak tüm abutmentlar dijital tork ölçer aleti ile firmaların önerdiği tork değerlerinde sıkılıp 5 dakika bekletildikten sonra söküldü. Bu işlem her implant için 15 kez tekrarlandı. Deneyin ikinci kısmında ise her iki grup termosiklus uygulamasından sonra elde edilen geri sökülme tork değerleri kaydedildi. Elde edilen tüm veriler student t test ve oneway anova testi ile istatistiksel olarak değerlendirildi (p<0.05). Strauman Bone Level implantları kuru ve klorheksidin uygulanmış haliyle başlangıç tork değerlerine göre en az kayıp ile geri sökülen implant olmuşlardır (2.66Ncm ve 3.91Ncm sırasıyla), Astra implantları ise kuru ve klorheksidinli ortamda en çok kayıp ile geri sökülen implant olmuştur (4.01Ncm ve 6.23Ncm sırasıyla). Sonuç olarak kuru ve klorheksidinli ortamda tekrarlayan sıkılma ve sökülme işlemini takiben başlangıç tork değerlerinde her zaman kayıp görülmüştür. Antimikrobiyal bir ajan olarak kullanılan klorheksidin jelin geri söküm tork değerlerini düşürdüğü, termosiklus uygulamasının ise herhangi bir etkisinin olmadığı görülmüştür.

Özet (Çeviri)

SUMMARY Ozdemir K. The Effect of Chlorhexidine Gel on Removal Torque Values of Different Dental Implant Systems. Yeditepe University Health Sciences Institute, PhD Thesis in Prosthetic Dentistry, İstanbul, 2012. Osseointegrated implants is a good represent now on acceptable treatment modality for complete or edentulous patients. Despite the recognized success, mechanical and biological failures associated with implant restorations represent a challenge to clinicians. Among the types of mechanical and biological failures abutment screw loosing and periimplantitis is still the most frequently reported complications. The aim of this study was to verify whether screw abutment lubrication with chlorhexidine gel can generate higher preload values compared to non-lubricated screws and determine if chlorhexidine has any extra mechanical advantage with it's biological advantage. Total of 24 new implants and abutments from (Astra, Zimmer, Straumann Bone Level, Straumann Standart Plus) each system were mounted in acrylic resin and the abutments were distrubuted in dry and chlorhexidine groups. In the chlorhexidine group the inner threads were filled with chlorhexidine gel. All abutments were fastaned with digital torque screw driver (DID-4) to their manifacturers recomended torque values and then detorqued after 5 minutes for 15 times. Thermocycling was performed for all implant systems both for dry and chlorhexidine groups for 1000 cycle. The mean detorque values were calculated and compared by student t-test and oneway anova test (p<0.05). Straumann Bone Level presented both in dry and chlorhexidine conditions showed the lowest loss of the initial torque values (2.66Ncm and 3.91Ncm respectively). Astra has the highest initial torque loss both for dry and chlorhexidine conditions (4.01Ncm and 6.23Ncm respectively). In conclusion there was always a loss in initial torque values when the removal torque was measured under both dry and chlorhexidine conditions. The chlorhexidine group presented in all implant abutment systems showed lower detorque values than the dry groups. Termocycling has no effect on removal torque values both in dry and chlorhexidine groups for all implant systems.

Benzer Tezler

  1. Implant bağlantı tipinin, klorheksidinin ve elastomerik tıkayıcıların dinamik koşullarda implant-abutment ara yüzündeki bakteriyel sızdırmazlığa etkisi

    Effects of connection geometry and sealant agents on bacterial leakage along the implant-abutment interface:An in vitro study under loaded conditions

    ARDA ÖZDİLER

    Doktora

    Türkçe

    Türkçe

    2017

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. FATMA GÜLBAHAR IŞIK ÖZKOL

  2. Dental implant içine yerleştirilen farklı konsantrasyonlarda klorheksidin ve polimer oranına sahip jellerin implant içi bakteriyel üreme üzerine kısa ve uzun dönem etkilerinin in vitro olarak incelenmesi

    In vitro examination of short and long term effects of gels with varying clorhexidine to polymer concentration ratios installed into dental implants on bacterial growth within the implant

    SEÇİL ÇOPUROĞLU

    Doktora

    Türkçe

    Türkçe

    2015

    Diş HekimliğiHacettepe Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    DOÇ. DR. ALPER AKTAŞ

  3. Farklı irrigasyon maddelerinin kök kanal dolgu patlarının sızdırmazlığına etkisi

    Sealing effectof different irrigation solutions upon root canal sealers

    TÜLİN ERTAN

    Doktora

    Türkçe

    Türkçe

    2006

    Diş HekimliğiGata

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    DOÇ. YASAR MERIC TUNCA

  4. Farklı iletken maddelerin elektrikli pulpa testinin cevabına etkisi

    The effect of different conductive materials on response of electrical pulp test

    EMİNE DEMİR ŞEREFLİ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiTokat Gaziosmanpaşa Üniversitesi

    Endodonti Ana Bilim Dalı

    DOÇ. DR. HÜDA MELİKE BAYRAM

  5. İn vitro olarak dentin bağlayıcı ajanların demiralize dentin üzerindeki antibakteriyel etkilerinin karşılaştırılması

    Comparison of antibacterial effects of dentin bonding agents on demineralized dentin in vitro.

    HANDE ŞAR SANCAKLI

    Doktora

    Türkçe

    Türkçe

    2007

    Diş Hekimliğiİstanbul Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    PROF. SAMİ BÜYÜKGÖKÇESU