Farklı iletken maddelerin elektrikli pulpa testinin cevabına etkisi
The effect of different conductive materials on response of electrical pulp test
- Tez No: 536776
- Danışmanlar: DOÇ. DR. HÜDA MELİKE BAYRAM
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Elektrikli pulpa testi, pulpa eşik değeri, iletken madde, Dental pulpa, Diş macunları, Teşhis testleri, İletkenler, İletkenlik, Electrical pulp test, pulp threshold, conductive material, Dental pulp, Toothpaste, Diagnostic tests, Conductors, Conductivity
- Yıl: 2019
- Dil: Türkçe
- Üniversite: Tokat Gaziosmanpaşa Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Endodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: İletken materyal olarak su bazlı jeller ve diş macunları olarak iki grup materyal (Colgate Total diş macunu, Tebodont diş macunu, Flor jeli, Ultrason jeli ve Klorheksidin jeli) kullanılmasının ve cinsiyetin elektrikli pulpa testinin cevabına etkisini karşılaştırmaktır. Önemi: Elektrikli pulpa testinde kullanılan iletken maddenin ve cinsiyetin testin cevabına etkisi, dişlere doğru teşhis koymamızda önemlidir. Yöntem: Farklı iletken maddelerin ve cinsiyetin elektrikli pulpa testinin cevabına etkisini incelemek için 20 erkek, 20 kadın toplam 40 sağlıklı gönüllünün sağlıklı 40 üst keser dişi seçildi. Colgate Total, Tebodont, Flor jeli, Ultrason jeli ve Klorjeksidin jel iletken materyal olarak her dişe sırasıyla uygulanmıştır. Verilerin istatistiksel değerlendirilmesi IBM SPSS Versiyon 21.0 yazılımı kullanılarak, One-Sample Kolmogrov-Smirnov, Mann-Whitney U, Friedman ve Bonferroni düzeltmeli Wilcoxon testleriyle yapıldı. Bulgular: Pulpal duyu eşikleri açısından karşılaştırıldığında flor jeli; colgate, tebodont ve klorheksidin jelden (p<0.001, p<0.001 ve p=0.001) anlamlı derecede daha düşük eşik değerine sahipti. Ultrason jeliyle aralarında anlamlı farklılık bulunmamıştır. Colgate, tebodonttan (p=0.005 ) anlamlı derecede daha düşük eşik değerine sahipken ultrason jeli (p=0.001) ile karşılaştırıldığında anlamlı derecede daha yüksek eşik değeri gösterdi. Colgate ile chx jel arasında anlamlı bir farklılık bulunmadı. Tebodont; chx jel ve ultrason jeli karşılaştırıldığında (p<0.001) anlamlı düzeyde daha yüksek eşik değerine sahipti. Chx jel ve ultrason jeli arasında istaistiksel olarak anlamlı bir fark bulunmadı (p=0,013). Sonuç: Sonuç olarak su bazlı jel gruplarının diş macunlarından daha iyi bir iletkenliğe sahip olduğu ve cinsiyetin eşik değere anlamlı etkisi olmadığı bulunmuştur.
Özet (Çeviri)
Aim: To compare the effect of using two groups of materials (Colgate Total toothpaste, Tebodont toothpaste, Fluorine gel, Ultrasound gel and Chlorhexidine gel) which water-based gels and toothpastes as conductive materials and the effect of gender on electrical pulp testing. Importance: The effect of the conductive materials and gender is important for correct diagnosis on response of electrical pulp testing. Method: To investigate the effect of different conductive materials and gender on the response of electrical pulp test, 40 maxillary central tooth of 40 healthy volunteers (20 male and 20 female) were selected. Colgate Total, Tebodont, Fluorine gel, Ultrasound gel and Chlorjexidine gel were applied to each tooth respectively as the conductive material. The statistical evaluation was performed using the IBM SPSS Version 21.0 software, with the One-Sample Kolmogrov-Smirnov, Mann-Whitney U, Friedman and Bonferroni-corrected Wilcoxon tests. Results: In terms of pulpal sensory thresholds, fluorine gel; colgate, tebodont and chlorhexidine gel (p<0.001, p<0.001 and p=0.001) had significantly lower threshold value. No significant difference was found between ultrasound gel and fluorine gel. Colgate had a significantly lower threshold than tebodont (p=0.005), but significantly higher threshold than ultrasound gel (p=0.001). No significant difference was found between Colgate and chx gel. Tebodont; compared with chx gel and ultrasound gel (p<0.001), it had significantly higher threshold value. No statistically significant difference was found between Chx gel and ultrasound gel (p=0.013). It was found that water-based gel groups had better conductivity than toothpastes and gender had no significant effect on threshold value.
Benzer Tezler
- Al-Cu bimetal kompozitlerinin elektrik anahtarlarında iletken olarak kullanılabilirliğinin araştırılması
Investigation of the usage of Al-Cu bimetal composites as conductors in electric switches
HÜSEYİN TUNAHAN GÖZEL
Yüksek Lisans
Türkçe
2022
Makine MühendisliğiSakarya Uygulamalı Bilimler ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
DOÇ. DR. İDRİS CESUR
- Development of cathode and interlayer materials for high performance lithium sulfur batteries
Yüksek performanslı lityum sülfür pillerin katot ve seperatör kısmında malzeme geliştirmeleri
MMARYAM SADAT KİAİ
Doktora
İngilizce
2020
Enerjiİstanbul Teknik ÜniversitesiNanobilim ve Nanoteknoloji Ana Bilim Dalı
PROF. DR. HÜSEYİN KIZIL
- Contribution a la recherche d'un cadre juridique pour un droit international de laconcurrence plus efficace
Daha etkin bir uluslararası rekabet için hukuki çerçeve arayışı
ALİ CENK KESKİN
Doktora
Fransızca
2009
HukukGalatasaray ÜniversitesiKamu Hukuku Ana Bilim Dalı
PROF. DR. JEAN MARC SOREL
PROF. DR. HALİL ERCÜMENT ERDEM
- Farklı asitlerle katkılanmış polianilinin sentezi, karakterizasyonu ve süperkapasitör uygulaması
Synthesis, characterization and supercapacitor application of polyaniline doped with different acids
MERVE METİN ÇELENK
Yüksek Lisans
Türkçe
2022
Kimya Mühendisliğiİstanbul Teknik ÜniversitesiKimya Mühendisliği Ana Bilim Dalı
PROF. DR. FATMA SENİHA GÜNER
DR. YURDANUR TÜRKER
- Investigation of thermal propagation in electric vehicle high voltage batteries
Elektrikli araç yüksek gerilim bataryalarında ısıl yayılım araştırması
KADİR ARAS
Yüksek Lisans
İngilizce
2023
Enerjiİstanbul Teknik ÜniversitesiEnerji Bilimi ve Teknolojileri Ana Bilim Dalı
PROF. DR. NİLGÜN YAVUZ