Geri Dön

Dijital görüntülemede farklı tasarımdaki gridlerin görüntü kalitesi ve radyasyon dozuna etkisi

The effect of antiscatter grids with different designs to image quality and radiation dose in digital imaging with X-ray

  1. Tez No: 337005
  2. Yazar: ÜMRAN ÖNAL
  3. Danışmanlar: YRD. DOÇ. DR. ÖZLEM BİRGÜL
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Gridler, saçılan radyasyon, dijital x-ışını görüntüleme sistemleri, görüntü kalitesi fantomları, Anti-scatter grid, scatter raditions, digital x-ray imaging systems, imaging quality phantoms
  7. Yıl: 2013
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Dijital x-ışın görüntüleme sistemlerinde, saçılan ışınları önlemek ve görüntü kontrastını arttırmak için kullanılan gridler, hasta dozunu arttırmaktadır. Özellikle, dijital pediatrik uygulamalarda, grid kullanımı ve grid seçimi için gridlerin performans özellikleri hakkında detaylı bilgi gerekmektedir. Bu çalışmada, IEC protokolleri esas alınarak farklı kalınlıklar ve kVp'ler için grid performans testleri ile bucky faktörü, grid hassasiyeti, kontrast iyileştirme faktörü, sinyal gürültü oranı iyileştirme faktörü bulunmuş, sonrasında görüntü kalitesi testleri ile kontrast, bucky faktörü ve sinyal gürültü oranı iyileştirme faktörü incelenmiştir. Görüntü kalitesi ve grid performans parametreleri arasındaki ilişkilere bakılmış ve görüntü kalitesi parametrelerinin grid seçiminde nasıl kullanılabileceği tartışılmıştır. Buna ek olarak özellikle pediatrik incelemelerde grid seçimi hakkında daha detaylı incelemeler yapılmıştır. Sonuç olarak, tek bir kVp veya saçıcı kalınlığına bağlı kalmadan, görüntü kalite testleri yardımıyla, uygulamanın nitelikleri doğrultusunda grid seçiminde kullanılabilecek ölçütler belirlenmiştir. Böylelikle, klinik ortamda uygulanması pratik ve özellikle pediatrik incelemelerde olduğu gibi doz seviyelerinin kritik olduğu durumlarda grid kullanılması veya grid seçimi hakkında kullanıcıya kolaylık sağlayan bir yöntem önerilmiştir.

Özet (Çeviri)

In digital imaging with x-rays, anti-scatter grids that are used for reducing scattered rays to increase image contrast causes an increase in patient dose. Especially, detailed information on use of grid and grid performance characteristics are required for digital pediatric applications. In this work, bucky factor, grid sensitivity, contrast improvement factor and signal-to-noise ratio improvement factor are found using grid performance tests based on IEC protocols and then contrast, bucky factor and signal-to-noise ratio improvement factor are calculated using image quality tests, for different scatterer thicknesses and kVp values. The correlation between image quality and grid performance parameters are investigated and the use of image quality metrics for grid selection is discussed. Additionally, detailed analysis of grid selection for pediatric studies is carried out. As a result, metrics for grid selection that can be obtained using image quality tests without being limited to a single scatterer thickness or to a single kVp value are determined. With this approach, a method which is practical for clinical use and that can simplify decision making process in grid usage and grid selection, especially for pediatric application, is proposed.

Benzer Tezler

  1. Film-ekran, dijitize film-ekran ve dijital radyografi sistemlerinde hasta dozu ve görüntü kalitesi optimizasyonu

    Patient dose and imaging quality optimisation in screen-film system, digitalization of film and digital radiography

    ELİF ÜNAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. MEHMET DOĞAN BOR

  2. Mimari tasarım eğitiminde sarmal sanal gerçeklik ortamının mekansal ilişkilerin algısına etkisi

    The effect of the immersive virtual reality on perception of topological relations in architectural design education

    İLKE YILDAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Mimarlıkİstanbul Teknik Üniversitesi

    Bilişim Ana Bilim Dalı

    PROF. DR. GÜLEN ÇAĞDAŞ

  3. Meme tümörlerinin çok geniş bantlı radar tabanlı mikrodalga yöntemiyle tespiti

    Detection of the breast tumors by ultra-wideband radar based microwave method

    ALİ RECAİ ÇELİK

    Doktora

    Türkçe

    Türkçe

    2018

    Elektrik ve Elektronik MühendisliğiDicle Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MUHAMMED BAHADDİN KURT

    PROF. DR. SELÇUK HELHEL

  4. CMOS current mode exponential function generator circuit using Pade approximation

    Pade yaklaşıklığı kullanan akım modlu CMOS eksponansiyel fonksiyon üretici devresi

    DUYGU KUTLUOĞLU

    Yüksek Lisans

    İngilizce

    İngilizce

    2015

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    PROF. DR. ALİ TOKER

  5. Bilgisayar destekli fotografik tasarımda biçim ve içerik

    Form and content in computer aided photographic design

    EMRE İKİZLER

    Sanatta Yeterlik

    Türkçe

    Türkçe

    2009

    Güzel SanatlarMimar Sinan Güzel Sanatlar Üniversitesi

    Fotoğraf Ana Sanat Dalı

    PROF. AHMET ÖNER GEZGİN