Film-ekran, dijitize film-ekran ve dijital radyografi sistemlerinde hasta dozu ve görüntü kalitesi optimizasyonu
Patient dose and imaging quality optimisation in screen-film system, digitalization of film and digital radiography
- Tez No: 352014
- Danışmanlar: PROF. DR. MEHMET DOĞAN BOR
- Tez Türü: Yüksek Lisans
- Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
- Anahtar Kelimeler: Film-Ekran, dijitize, dijital radyografi, hasta dozu, hümanoid fantom, görüntü kalitesi, Screen-Film, digitalization, digital radiography, patient dose, humanoid phantom, image quality
- Yıl: 2014
- Dil: Türkçe
- Üniversite: Ankara Üniversitesi
- Enstitü: Nükleer Bilimler Enstitüsü
- Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
- Bilim Dalı: Sağlık Fiziği Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Dijital radyografi görüntüleme sistemlerinin analog film-ekran sistemlerine göre avantajı yanlış ışınlama parametreleri kullanılmasından kaynaklanan tekrar çekimlerini önemli ölçüde azaltmasıdır. Böylelikle hastaların gereksiz ışınlamaları önlenmiş olur. Ayrıca sayısal görüntülemelere uygulanan algoritmalar ile görüntü kalitelerinin arttırılması mümkündür.Ancak, dijital sistemlerde radyasyon dozu-detektör yanıtının doğrusal olması herhangi bir incelemedeki hasta dozunu önemli ölçüde arttırabilir. Bu bağlamda radyasyon dozu görüntü kalitesi optimizasyonunun birçok klinik inceleme için yapılması gerekmektedir. Dozimetrik ve görüntü kalite ölçümleri hastalar yerine fantomlar kullanılarak gerçekleştirilir. Genel olarak radyografik incelemeler için fantom giriş dozunun ölçülmesi yaygın olarak kullanılan bir tekniktir, ancak görüntü kalitesinin spesifik bir parametresinin ölçülmesine yönelik bir çok tasarım olması fantom seçimini kritik hale getirir. Bu tez çalışmasında farklı klinik incelemelerde alınan hasta cilt dozlarının saptanması, hümanoid fantomlarda ve vücudun değişik organlarının benzeşimini veren PMMA ve ANSI tabakalarında giriş radyasyon dozlarının ölçülmesi ile araştırılmıştır. Görüntü kaliteleri, hümanoid fantomlarda gerçekleştirilen farklı yapıların görüntü kontrastlarından, PMMA ve ANSI fantomlarında ise bu fantomlar arasına yerleştirilen değişik görüntü kalite kontrol fantomları ile değerlendirilmiştir. Basit tasarımdaki PMMA ve ANSI fantomlarının tasarımları kompleks olan hümanoid fantomlara göre kullanımları karşılaştırılmıştır ve spesifik klinik incelemelerine en uygun görüntü kalitesi fantomları saptanmıştır.
Özet (Çeviri)
The advantages of digital radiographic imaging systems over the analog film/screen systems are the reduction of retakes occurring from the inappropriate handling of exposure parameters. Thus, the unnecessary exposure of the patients are avoided, Beside, the improvement of the image quality through the application of suitable algorithms to digital images are possible. However the linear relationship of radiation dose-detector response of digital systems may increase the patient radiation dose for a specific exam. Thereforthe radiation dose to image quality balance has to be done correctly for the majority of the clinical examinations. Dosimetric and image quality measurements are usually made by using phantoms instead of patients. In general, measurements of phantom entrance dose is a well-accepted technique for the radiographic examinations, but the presence of various phantoms designed for the measurement of a specific parameter of image quality requires a careful evaluation of phantom selection. In this thesis, the amount of patient skin doses received at various clinical examinationswere investigated by measuring the entrance radiation doses for humanoid phantoms and also for the PMMA and ANSI phantoms simulating the different organs of humans.Image qualities were found from the image contrast of different structures of humanoid phantoms and from the evaluation of various image quality control phantoms placed into the PMMA and ANSI phantoms. The use of PMMA and ANSI phantoms having simple designs were compared with the use of complex humanoid phantoms and selection of most appropriate quality control phantom for a specific clinical exam were carried out.
Benzer Tezler
- Mamografi sistemlerinde optimum film/ekran kombinasyonlarının saptanması
Optimisation of film/screen combinations for mammography systems
KERİME AKDUR
Yüksek Lisans
Türkçe
2012
Fizik ve Fizik MühendisliğiAnkara ÜniversitesiMedikal Fizik Ana Bilim Dalı
PROF. DR. DOĞAN BOR
- Şüpheli pnömokonyoz olgularında, PA akciğer grafilerinin, ekran ve film değerlendirmeleri karşılaştırması
Comparison of hard copy and soft copy evaluation of chest Z rays in suspicious pneumoconiotic findings
ENDER EVCİK
- James Bond film jeneriklerinin incelenmesi ve bir jenerik uygulaması
Research of James Bond movie generics and a simple generic design
ONUR TOPRAK
Sanatta Yeterlik
Türkçe
2019
Radyo-TelevizyonGazi ÜniversitesiBileşik Sanatlar Ana Sanat Dalı
YRD. DOÇ. DR. GÜZİN AYRANCIOĞLU
- Eritilmiş-soğutulmuş üstüniletken YBCO örneklerinin yapısal ve elektriksel özellikleri
Structural and electrical properties of melt-quenched YBCO samples
AYHAN AKKAŞ
Yüksek Lisans
Türkçe
2006
Fizik ve Fizik MühendisliğiHacettepe ÜniversitesiFizik Mühendisliği Ana Bilim Dalı
PROF.DR. NECDET BAŞTÜRK
- İstanbul'un alternatif film gösterim mekânları: Çağdaş müzeler
Alternative film exhibition of İstanbul: Contemporary museum
ATİFET KELEŞOĞLU
Yüksek Lisans
Türkçe
2019
Sahne ve Görüntü SanatlarıMarmara ÜniversitesiRadyo Televizyon ve Sinema Ana Bilim Dalı
PROF. DR. MEHMET ÖZTÜRK